# Delta VCA605LED-H Ceiling Fan Specs

Delta VCA605LED-H (Standard Fan with Light Kit) places #73 of 1,241 certified U.S. ceiling fans with Airflow Efficiency 333.6 CFM/W and 60.0 in span. Sized for a standard residential footprint, this chassis consolidates single SKU VCA605LED-HEBK to prevent duplicate parts lookup. Projected electricity totals rated service expectations across a 15-year NAHB lifespan at August 2026 EIA rates, keeping ENERGY STAR certified headroom under federal 10 CFR 430 rules.

- **Rated Energy** : Ceiling Fans

- **EIA Annual Cost** : Not listed

- **Category Rank** : #73 of 1,241

- **Capacity** : 60.0 in span

- **NAHB Lifespan** : 15 years

[All Brand Serial Guides](https://lamcoewp.com/serial-decoder/) [Delta Brand Profile](https://lamcoewp.com/brands/delta/) [All Ceiling Fans (1,241)](https://lamcoewp.com/models/ceiling-fan/)

Annual Energy Draw Certified Rank #73 / 1,241 (top 5.9%)

vs Ceiling Fans Median +123.7 CFM/W (+58.9%) EPA certified comparison

Federal Metric (Airflow Efficiency) 333.6 CFM/W 10 CFR 430 certified

Est. Operating Cost Unrated Annual kWh not listed

## What are the official specs and computed benchmarks for Delta VCA605LED-H?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.

Delta VCA605LED-H — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)

| Specification / Metric | VCA605LED-H Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| **Capacity** | 60.0 in span [[U.S. Environmental Protection Agency (ENERGY STAR)]](https://data.energystar.gov/resource/2te3-nmxp.json) | Standard in span rating | Density unavailable |
| **Listing & Release** | Released 2022 | 1 SKU | Single model listing (1 SKU) |
| **NAHB Service Life** | 15 years [[National Association of Home Builders (NAHB)]](https://www.nahb.org/) | 50% age gate: 7.5 yrs | Evaluate repair vs net replacement once age passes 9.8 yrs |
| **Airflow Efficiency** | 333.6 CFM/W | Standard Fan with Light Kit | Certified efficiency metric |

## Which ceiling fans match VCA605LED-H in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Ceiling Fans (Matched by Width & kWh Draw)

| Peer Model | Subtype | kWh/yr | Delta vs VCA605LED-H | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| [**Big Ass Fans MK-HK4-052500**](https://lamcoewp.com/models/ceiling-fan/big-ass-fans/mk-hk4-052500/) | Low-Mount HSSD Fan Only | Not listed | Not listed | 60.0 in span | Not listed | 1 |
| [**Big Ass Fans MK-HK4-05240001**](https://lamcoewp.com/models/ceiling-fan/big-ass-fans/mk-hk4-05240001/) | Low-Mount HSSD Fan Only | Not listed | Not listed | 60.0 in span | Not listed | 1 |
| [**Big Ass Fans MK-HK4-052400**](https://lamcoewp.com/models/ceiling-fan/big-ass-fans/mk-hk4-052400/) | Low-Mount HSSD Fan Only | Not listed | Not listed | 60.0 in span | Not listed | 1 |
| [**AERATRON FR3WI60**](https://lamcoewp.com/models/ceiling-fan/aeratron/fr3wi60/) | Standard Fan Only | Not listed | Not listed | 60.0 in span | Not listed | 1 |
| [**AERATRON FR3WI60L**](https://lamcoewp.com/models/ceiling-fan/aeratron/fr3wi60l/) | Standard Fan with Light Kit | Not listed | Not listed | 60.0 in span | Not listed | 1 |

## Does VCA605LED-H carry R-600a, duct, or installation boundaries?

VCA605LED-H (Standard Fan with Light Kit, 333.6 CFM/W) mounts to a UL-listed fan-rated ceiling electrical box with >= 7 ft blade clearance above floor.

Shut off wall switch and circuit breaker before servicing canopy wiring or balancing downrod blades.

- VCA605LED-HEBK

## Should you repair VCA605LED-H or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

Age (yrs)

Repair ($)

New Unit ($)

HEAR Credit

## FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

### What is the projected 15-year power cost for Delta VCA605LED-H?

Multiplying certified ENERGY STAR status by the U.S. EIA residential average of 18.16 cents/kWh places Delta VCA605LED-H running cost at scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) over its 15-year NAHB component life.

### Does Delta VCA605LED-H outperform the ceiling fans category median?

Against a category median of 0.0 kWh/yr across 1,241 chassis, Delta VCA605LED-H stands at rank #73: +123.7 CFM/W (+58.9%); Rank #73 / 1,241 (top 5.9%).

### What is the 50% cost threshold for Delta VCA605LED-H repairs?

Subtract eligible incentives and 5-year energy savings ($150) from replacement retail price, then cap repair quotes at 50% once age exceeds 7.5 years.

### Which installations do NOT fit Delta VCA605LED-H?

Skip Delta VCA605LED-H if your cabinet cutout cannot fit OEM cutout blueprint, if 60.0 in span cannot clear household doorways, or if commercial throughput exceeds residential engineering limits.

### Why are 1 SKU variants grouped under Delta VCA605LED-H?

Manufacturers file separate paint letters such as VCA605LED-HEBK for one mechanical chassis; grouping them shows true certified ENERGY STAR status and 60.0 in span specs without duplicate model clutter.

### Which hazards forbid uncertified work on Delta VCA605LED-H?

Always shut off the electrical breaker and water shutoff valve before opening VCA605LED-H service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

### Can you swap Delta VCA605LED-H without modifying kitchen framing?

Inspect the 5 nearest peers matched to OEM cutout blueprint and 60.0 in span; selecting a peer matching VCA605LED-H's width avoids countertop or cabinet trim alterations.

### Why screen recall notices for Delta VCA605LED-H before paid service?

Active CPSC safety notices entitle owners to no-charge OEM remedies; always verify your exact serial number on CPSC recall bulletins before booking out-of-warranty work.

## Related guides

-  [ All Brand Serial Guides  ](https://lamcoewp.com/serial-decoder/)
-  [ Delta Brand Profile  ](https://lamcoewp.com/brands/delta/)
-  [ Compare Repair Quote vs HEAR Replacement Net Cost  ](https://lamcoewp.com/tools/repair-vs-replace/)
-  [ Hunter 55132 Specs  ](https://lamcoewp.com/models/ceiling-fan/hunter/55132/)
-  [ Hunter 53480 Specs  ](https://lamcoewp.com/models/ceiling-fan/hunter/53480/)
-  [ Monte Carlo 6LFR62RZ Specs  ](https://lamcoewp.com/models/ceiling-fan/monte-carlo/6lfr62rz/)

## Sources

1. [ENERGY STAR Certified Ceiling Fans Dataset (2te3-nmxp)](https://data.energystar.gov/resource/2te3-nmxp.json) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
2. [Study of Life Expectancy of Home Components](https://www.nahb.org/) — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
3. [Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)