title: "Bertazzoni MAS365IN (187 kWh/yr, #6)"
url: https://lamcoewp.com/models/electric-cooking/bertazzoni/mas365in/
description: "Bertazzoni MAS365IN (5.0 zones, 187 kWh/yr, $33.96/yr EIA, rank #6 of 234 electric cooking) with 5 peer models. Compare verified federal data, licensing."
---

Electric Cooking · Rank #6 of 234

# Bertazzoni MAS365IN Electric Cooking Specs

Bertazzoni MAS365IN (Range) places #6 of 234 certified U.S. electric cooking with 187 kWh/yr ($33.96/yr at 18.16c/kWh) and 5.0 zones. Sized for a 42-inch wide built-in opening, this chassis consolidates 2 finish SKUs including MAS365INMNG, MAS365INMBG to prevent duplicate parts lookup. Projected electricity totals $441.48 over a 13-year NAHB lifespan at August 2026 EIA rates, keeping ENERGY STAR certified headroom under federal 10 CFR 430 rules.

- **Rated Energy** : 187 kWh/yr

- **EIA Annual Cost** : $33.96/yr

- **Category Rank** : #6 of 234

- **Capacity** : 5.0 zones

- **NAHB Lifespan** : 13 years

[All Brand Serial Guides](https://lamcoewp.com/serial-decoder/) [Bertazzoni Brand Profile](https://lamcoewp.com/brands/bertazzoni/) [All Electric Cooking (234)](https://lamcoewp.com/models/electric-cooking/)

Annual Energy Draw 187 kWh/yr Rank #6 / 234 (top 5.1%)

vs Electric Cooking Median -8 kWh/yr (-4.1%) Median 195.0 kWh/yr

Federal Metric (Boil Test Time) 8.0 min 10 CFR 430 certified

Est. Operating Cost $33.96/yr $441 over 13 yr NAHB

## How does MAS365IN compare across all 234 electric cooking?

Bertazzoni MAS365IN (187 kWh/yr) sits against the electric cooking category median of 195.0 kWh/yr, -8 kWh/yr (-4.1%), and U.S. 10 CFR 430 baselines.

View quantile summary for Electric Cooking — MAS365IN

| Quantile / Marker | Annual kWh/yr |
|---|---|
| Most efficient model | 175 kWh/yr kWh |
| 25th percentile | 190 kWh/yr kWh |
| Category median | 195 kWh/yr kWh |
| 75th percentile | 195 kWh/yr kWh |
| Highest rated draw | 195 kWh/yr kWh |

## Where does MAS365IN rank in operating-cost percentile?

Ranked #6 of 234 rated electric cooking using EIA August 2026 national residential electricity rates (18.16 cents/kWh) over a 13-year NAHB median lifespan.

## What are the official specs and computed benchmarks for Bertazzoni MAS365IN?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (13 years), and estimated operating electricity costs at 18.16 cents/kWh.

Bertazzoni MAS365IN — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)

| Specification / Metric | MAS365IN Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| **Rated Energy** | 187 kWh/yr [[U.S. Environmental Protection Agency (ENERGY STAR)]](https://data.energystar.gov/resource/m6gi-ng33.json) | Median 195 kWh/yr | Rank #6 of 234 electric cooking (tied with 6 peers) (-8 kWh/yr, -4.1% vs median) |
| **Capacity** | 5.0 zones [[U.S. Environmental Protection Agency (ENERGY STAR)]](https://data.energystar.gov/resource/m6gi-ng33.json) | Standard zones rating | 37.4 kWh/zones (-21.3% vs 47.5 median) |
| **Cutout W × H × D** | 36.0 × 32.0 × 27.0 in [[U.S. Environmental Protection Agency (ENERGY STAR)]](https://data.energystar.gov/resource/m6gi-ng33.json) | Released 2024 | Consolidates 2 finish variants |
| **Operating Cost (EIA)** | $33.96/yr [[U.S. Energy Information Administration (EIA)]](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) | 18.16 c/kWh US avg | Formula: 187 kWh × $0.1816 = $33.96/yr ($441.48 over 13 yrs) |
| **NAHB Service Life** | 13 years [[National Association of Home Builders (NAHB)]](https://www.nahb.org/) | 50% age gate: 6.5 yrs | Evaluate repair vs net replacement once age passes 8.5 yrs |
| **Boil Test Time** | 8.0 min | 240 V | Certified efficiency metric |

## Which electric cooking match MAS365IN in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Electric Cooking (Matched by Width & kWh Draw)

| Peer Model | Subtype | kWh/yr | Delta vs MAS365IN | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| [**Samsung NZ36C3060**](https://lamcoewp.com/models/electric-cooking/samsung/nz36c3060/) | Cooktop | 189 | +2 kWh | 5.0 zones | 36.0 × 4.13 × 21.25 in | 1 |
| [**Ikea MC-8F72A2H333UL**](https://lamcoewp.com/models/electric-cooking/ikea/mc-8f72a2h333ul/) | Cooktop | 188 | +1 kWh | 5.0 zones | 36.61 × 2.17 × 21.46 in | 1 |
| [**Midea MC-9V96E0H378UL**](https://lamcoewp.com/models/electric-cooking/midea/mc-9v96e0h378ul/) | Cooktop | 188 | +1 kWh | 6.0 zones | 35.98 × 2.36 × 20.91 in | 1 |
| [**Midea MC-9V96E1H378UL**](https://lamcoewp.com/models/electric-cooking/midea/mc-9v96e1h378ul/) | Cooktop | 188 | +1 kWh | 6.0 zones | 35.98 × 2.36 × 20.91 in | 1 |
| [**LG CBIH3613*E**](https://lamcoewp.com/models/electric-cooking/lg/cbih3613-e/) | Cooktop | 189 | +2 kWh | 5.0 zones | 36.63 × 3.69 × 21.06 in | 1 |

## Does MAS365IN carry R-600a, duct, or installation boundaries?

MAS365IN (Range, 240 V, 36.0 in width) fits a standard countertop or slide-in cutout; confirm dedicated 40A-50A breaker ampacity before installation.

Induction glass-ceramic tops require ferromagnetic cookware and dedicated cooling fan clearance; high-voltage 240V IGBT/inverter board service requires a qualified technician.

- MAS365INMNG
- MAS365INMBG

## Should you repair MAS365IN or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

Age (yrs)

Repair ($)

New Unit ($)

HEAR Credit

## FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

### How much does running Bertazzoni MAS365IN cost each year?

At 18.16 cents/kWh (EIA August 2026), Bertazzoni MAS365IN draws 187 kWh/yr, equating to $33.96/yr ($441 over 13 years) across all 2 finish trims, specifically MAS365INMNG, MAS365INMBG.

### How efficient is Bertazzoni MAS365IN compared with federal ceilings?

Measured against 10 CFR 430 certified, Bertazzoni MAS365IN holds rank #6 out of 234 U.S. ENERGY STAR electric cooking: -8 kWh/yr (-4.1%) vs median 195.0 kWh/yr.

### Which minor parts are exceptions to replacing Bertazzoni MAS365IN?

Routine wear items such as gaskets, lint filters, coin traps, or inlet mesh remain worthwhile past 6.5 years, whereas motor or board quotes above 50% net replacement favor replacement.

### When is Bertazzoni MAS365IN a poor match for a remodel?

Avoid Bertazzoni MAS365IN if 5.0 zones falls short of household demand, if hookups conflict with 36.0 × 32.0 × 27.0 in, or if local electricity tariffs justify the lowest-kWh quartile.

### Do all variants in the Bertazzoni MAS365IN line use identical energy?

Yes; every listed finish — including MAS365INMNG, MAS365INMBG — shares the identical 187 kWh/yr ENERGY STAR test rating and 5.0 zones volume.

### What safety codes restrict Bertazzoni MAS365IN disassembly?

Always shut off the electrical breaker and water shutoff valve before opening MAS365IN service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

### How should owners confirm cutout clearance for Bertazzoni MAS365IN?

Verify width, height, and depth against 36.0 × 32.0 × 27.0 in, leaving extra rear space for cords, hoses, or condenser airflow.

### Where is the serial tag located on Bertazzoni MAS365IN?

Inspect the inner liner wall, door rim, or tub flange via the Bertazzoni serial guide to decode build month and year before buying replacement assemblies.

## Related guides

-  [ All Brand Serial Guides  ](https://lamcoewp.com/serial-decoder/)
-  [ Bertazzoni Brand Profile  ](https://lamcoewp.com/brands/bertazzoni/)
-  [ Compare Repair Quote vs HEAR Replacement Net Cost  ](https://lamcoewp.com/tools/repair-vs-replace/)
-  [ Bertazzoni PRO365INMX (187 kWh)  ](https://lamcoewp.com/models/electric-cooking/bertazzoni/pro365inmx/)
-  [ Bertazzoni MAS304IN (188 kWh)  ](https://lamcoewp.com/models/electric-cooking/bertazzoni/mas304in/)
-  [ Bertazzoni MAS304INMXV� (188 kWh)  ](https://lamcoewp.com/models/electric-cooking/bertazzoni/mas304inmxv/)

## Sources

1. [ENERGY STAR Certified Residential Electric Cooking Products (m6gi-ng33)](https://data.energystar.gov/resource/m6gi-ng33.json) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
2. [Study of Life Expectancy of Home Components](https://www.nahb.org/) — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
3. [Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)