title: "Hayward SP3206VSP (230V) (Pool Pumps, #329)"
url: https://lamcoewp.com/models/pool-pump/hayward/sp3206vsp-230v/
description: "Hayward SP3206VSP (230V) (2.7 HP, Pool Pumps, rank #329 of 405 pool pumps) with 5 peer models. Compare verified federal data, licensing rules, and."
---

Pool Pumps · Rank #329 of 405

# Hayward SP3206VSP (230V) Pool Pump Specs

Hayward SP3206VSP (230V) (In-Ground (Self-Priming) Pool Filter Pump) places #329 of 405 certified U.S. pool pumps with WEF 7.267 kgal/kWh and 2.7 HP. Sized for a standard residential footprint, this chassis consolidates single SKU SP3206VSP (230V) to prevent duplicate parts lookup. Projected electricity totals rated service expectations across a 10-year NAHB lifespan at August 2026 EIA rates, keeping ENERGY STAR certified headroom under federal 10 CFR 430 rules.

- **Rated Energy** : Pool Pumps

- **EIA Annual Cost** : Not listed

- **Category Rank** : #329 of 405

- **Capacity** : 2.7 HP

- **NAHB Lifespan** : 10 years

[All Brand Serial Guides](https://lamcoewp.com/serial-decoder/) [Hayward Brand Profile](https://lamcoewp.com/brands/hayward/) [All Pool Pumps (405)](https://lamcoewp.com/models/pool-pump/)

Annual Energy Draw Certified Rank #329 / 405 (lower half)

vs Pool Pumps Median -1.3 kgal/kWh (-14.7%) EPA certified comparison

Federal Metric (WEF) 7.267 kgal/kWh Fed min 5.22 kgal/kWh

Est. Operating Cost Unrated Annual kWh not listed

## What are the official specs and computed benchmarks for Hayward SP3206VSP (230V)?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (10 years), and estimated operating electricity costs at 18.16 cents/kWh.

Hayward SP3206VSP (230V) — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)

| Specification / Metric | SP3206VSP (230V) Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| **Capacity** | 2.7 HP [[U.S. Environmental Protection Agency (ENERGY STAR)]](https://data.energystar.gov/resource/m8cf-pkii.json) | Standard HP rating | Density unavailable |
| **Listing & Release** | Released 2017 | 1 SKU | Single model listing (1 SKU) |
| **NAHB Service Life** | 10 years [[National Association of Home Builders (NAHB)]](https://www.nahb.org/) | 50% age gate: 5.0 yrs | Evaluate repair vs net replacement once age passes 6.5 yrs |
| **WEF** | 7.267 kgal/kWh | Fed: 5.22 kgal/kWh | Certified efficiency metric |

## Which pool pumps match SP3206VSP (230V) in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Pool Pumps (Matched by Width & kWh Draw)

| Peer Model | Subtype | kWh/yr | Delta vs SP3206VSP (230V) | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| [**CARVIN 94026140**](https://lamcoewp.com/models/pool-pump/carvin/94026140/) | In-Ground (Self-Priming) Pool Filter Pump | Not listed | Not listed | 2.7 HP | Not listed | 1 |
| [**CARVIN 940261490N-CP**](https://lamcoewp.com/models/pool-pump/carvin/940261490n-cp/) | In-Ground (Self-Priming) Pool Filter Pump | Not listed | Not listed | 2.7 HP | Not listed | 1 |
| [**Waterco 2404270A-**](https://lamcoewp.com/models/pool-pump/waterco/2404270a/) | In-Ground (Self-Priming) Pool Filter Pump | Not listed | Not listed | 2.7 HP | Not listed | 1 |
| [**Waterco 2404270AVS-**](https://lamcoewp.com/models/pool-pump/waterco/2404270avs/) | In-Ground (Self-Priming) Pool Filter Pump | Not listed | Not listed | 2.7 HP | Not listed | 1 |
| [**Waterco 243270A-**](https://lamcoewp.com/models/pool-pump/waterco/243270a/) | In-Ground (Self-Priming) Pool Filter Pump | Not listed | Not listed | 2.7 HP | Not listed | 1 |

## Does SP3206VSP (230V) carry R-600a, duct, or installation boundaries?

SP3206VSP (230V) (In-Ground (Self-Priming) Pool Filter Pump, WEF 7.267 kgal/kWh) reduces residential circulation wattage dramatically at low-speed daily filtration RPMs.

Pool pumps run on 240V/120V GFCI-protected wet-area circuits with equipotential bonding grids—hire a licensed pool/electrical technician for motor or seal-plate service.

- SP3206VSP (230V)

## Should you repair SP3206VSP (230V) or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

Age (yrs)

Repair ($)

New Unit ($)

HEAR Credit

## FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

### How much electricity does the Hayward SP3206VSP (230V) draw each year?

EPA ENERGY STAR lists Hayward SP3206VSP (230V) at certified ENERGY STAR status, producing an estimated utility outlay of scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) at the U.S. EIA residential benchmark of 18.16 cents/kWh across 1 finish SKUs.

### How does Hayward SP3206VSP (230V) compare against the federal limit?

Against the Fed min 5.22 kgal/kWh, this Hayward pool pump ranks #329 among 405 certified pool pumps — -1.3 kgal/kWh (-14.7%) vs the 0.0 kWh/yr median.

### When is repairing Hayward SP3206VSP (230V) out of warranty NOT worthwhile?

Avoid major mechanical or control-board repairs once Hayward SP3206VSP (230V) passes 5.0 years (half its 10-year NAHB lifespan) or whenever a technician quote reaches 50% of net replacement cost.

### Who should NOT install the Hayward SP3206VSP (230V) pool pump?

Do not specify Hayward SP3206VSP (230V) (2.7 HP) for commercial duty cycles, tight alcoves that cannot clear OEM cutout blueprint plus ventilation gaps, or inside an active year-1 manufacturer warranty period.

### Which SKU trims map to the Hayward SP3206VSP (230V) appliance models?

CodeBench merges 1 finish code, led by SP3206VSP (230V), under SP3206VSP (230V) because color suffixes share identical core power draw, 2.7 HP volume, and outer cabinet dimensions.

### What safety rules govern Hayward SP3206VSP (230V) repairs?

Always shut off the electrical breaker and water shutoff valve before opening SP3206VSP (230V) service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

### How do 5 peer alternatives match up to Hayward SP3206VSP (230V)?

The peer table compares 5 pool pumps selected closest to SP3206VSP (230V) by cutout width, 2.7 HP capacity, and certified ENERGY STAR status rating so homeowners can evaluate direct drop-in replacements.

### How do you verify the build age of Hayward SP3206VSP (230V)?

Check the interior serial sticker with the Hayward serial date guide rather than relying only on the 2017 catalog release year, especially when 10-year codes repeat.

## Related guides

-  [ All Brand Serial Guides  ](https://lamcoewp.com/serial-decoder/)
-  [ Hayward Brand Profile  ](https://lamcoewp.com/brands/hayward/)
-  [ Compare Repair Quote vs HEAR Replacement Net Cost  ](https://lamcoewp.com/tools/repair-vs-replace/)
-  [ Hayward SP3206VSPBH (230V) Specs  ](https://lamcoewp.com/models/pool-pump/hayward/sp3206vspbh-230v/)
-  [ Hayward SP32950VSP (230V) Specs  ](https://lamcoewp.com/models/pool-pump/hayward/sp32950vsp-230v/)
-  [ Hayward SP32950VSPX1 (230V) Specs  ](https://lamcoewp.com/models/pool-pump/hayward/sp32950vspx1-230v/)

## Sources

1. [ENERGY STAR Certified Pool Pumps Dataset (m8cf-pkii)](https://data.energystar.gov/resource/m8cf-pkii.json) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
2. [Study of Life Expectancy of Home Components](https://www.nahb.org/) — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
3. [Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)