title: "Keystone KSTAW08I (400 kWh/yr, #85)"
url: https://lamcoewp.com/models/room-ac/keystone/kstaw08i/
description: "Keystone KSTAW08I (8000.0 BTU/hr, 400 kWh/yr, $72.64/yr EIA, rank #85 of 560 room air conditioners) with 5 peer models. Compare verified federal data."
---

Room Air Conditioners · Rank #85 of 560

# Keystone KSTAW08I Room Air Conditioner Specs

Spanning single SKU KSTAW08INV, Keystone KSTAW08I logs 400 kWh/yr ($72.64/yr at 18.16c/kWh) inside an 18-inch compact alcove built for 8000.0 BTU/hr. Out of 560 certified U.S. room air conditioners, this Window model achieves top-quartile efficiency: #85 / 560 — tied with 51 peers, uses less energy than 75.7% of 560 room air conditioners. Out-of-warranty owners weighing component quotes face $726.40 over a 10-year NAHB lifespan and 38% below limit compliance under 10 CFR 430.

- **Rated Energy** : 400 kWh/yr

- **EIA Annual Cost** : $72.64/yr

- **Category Rank** : #85 of 560

- **Capacity** : 8000.0 BTU/hr

- **NAHB Lifespan** : 10 years

[All Brand Serial Guides](https://lamcoewp.com/serial-decoder/) [Keystone Brand Profile](https://lamcoewp.com/brands/keystone/) [All Room Air Conditioners (560)](https://lamcoewp.com/models/room-ac/)

Annual Energy Draw 400 kWh/yr Rank #85 / 560 (tied with 51 at 400 kWh/yr)

vs Room Air Conditioners Median -132 kWh/yr (-24.8%) Median 531.9 kWh/yr

Federal Metric (CEER) 15.0 BTU/Wh 10 CFR 430 certified

Est. Operating Cost $72.64/yr $726 over 10 yr NAHB

## How does KSTAW08I compare across all 560 room air conditioners?

Keystone KSTAW08I (400 kWh/yr) sits against the room air conditioners category median of 531.9 kWh/yr, -132 kWh/yr (-24.8%), and U.S. 10 CFR 430 baselines.

View quantile summary for Room Air Conditioners — KSTAW08I

| Quantile / Marker | Annual kWh/yr |
|---|---|
| Most efficient model | 260.4 kWh/yr kWh |
| 25th percentile | 404.8 kWh/yr kWh |
| Category median | 531.9 kWh/yr kWh |
| 75th percentile | 647.5 kWh/yr kWh |
| Highest rated draw | 2096.3 kWh/yr kWh |

## Where does KSTAW08I rank in operating-cost percentile?

Ranked #85 of 560 rated room air conditioners using EIA August 2026 national residential electricity rates (18.16 cents/kWh) over a 10-year NAHB median lifespan.

## What are the official specs and computed benchmarks for Keystone KSTAW08I?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (10 years), and estimated operating electricity costs at 18.16 cents/kWh.

Keystone KSTAW08I — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)

| Specification / Metric | KSTAW08I Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| **Rated Energy** | 400 kWh/yr [[U.S. Environmental Protection Agency (ENERGY STAR)]](https://data.energystar.gov/resource/5xn2-dv4h.json) | Median 532 kWh/yr | Tied with 51 peers at 400 kWh/yr (-132 kWh/yr, -24.8% vs median) |
| **Capacity** | 8000.0 BTU/hr [[U.S. Environmental Protection Agency (ENERGY STAR)]](https://data.energystar.gov/resource/5xn2-dv4h.json) | Standard BTU/hr rating | 0.05 kWh/BTU/hr (matches 0.05 median) |
| **Cutout W × H × D** | 19.2 × 13.5 × 22.0 in [[U.S. Environmental Protection Agency (ENERGY STAR)]](https://data.energystar.gov/resource/5xn2-dv4h.json) | Released 2024 | Single model listing (1 SKU) |
| **Operating Cost (EIA)** | $72.64/yr [[U.S. Energy Information Administration (EIA)]](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) | 18.16 c/kWh US avg | Formula: 400 kWh × $0.1816 = $72.64/yr ($726.40 over 10 yrs) |
| **NAHB Service Life** | 10 years [[National Association of Home Builders (NAHB)]](https://www.nahb.org/) | 50% age gate: 5.0 yrs | Evaluate repair vs net replacement once age passes 6.5 yrs |
| **CEER** | 15.0 BTU/Wh | 115 | Certified efficiency metric |

## Which room air conditioners match KSTAW08I in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Room Air Conditioners (Matched by Width & kWh Draw)

| Peer Model | Subtype | kWh/yr | Delta vs KSTAW08I | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| [**Century RXTS-81**](https://lamcoewp.com/models/room-ac/century/rxts-81/) | Window | 400 | Same kWh | 8000.0 BTU/hr | 19.2 × 13.5 × 22.0 in | 1 |
| [**Comfort Aire RXTS-81**](https://lamcoewp.com/models/room-ac/comfort-aire/rxts-81/) | Window | 400 | Same kWh | 8000.0 BTU/hr | 19.2 × 13.5 × 22.0 in | 1 |
| [**Danby DAC080B7IWDB-6**](https://lamcoewp.com/models/room-ac/danby/dac080b7iwdb-6/) | Window | 400 | Same kWh | 8000.0 BTU/hr | 19.2 × 13.5 × 22.0 in | 1 |
| [**Danby DAC080B8IWDB-6**](https://lamcoewp.com/models/room-ac/danby/dac080b8iwdb-6/) | Window | 400 | Same kWh | 8000.0 BTU/hr | 19.2 × 13.5 × 22.0 in | 1 |
| [**Frigidaire Gallery GHWQ083WC1**](https://lamcoewp.com/models/room-ac/frigidaire-gallery/ghwq083wc1/) | Window | 400 | Same kWh | 8000.0 BTU/hr | 19.2 × 13.5 × 22.0 in | 1 |

## Does KSTAW08I carry R-600a, duct, or installation boundaries?

KSTAW08I (Window, 19.2 in width, CEER 15.0) cools matched room square footage efficiently using R-32 refrigerant.

Sealed refrigerant lines (R-32) are non-serviceable for DIY; keep washable intake filters and outdoor condenser fins clean every 30 days.

- KSTAW08INV

## Should you repair KSTAW08I or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

Age (yrs)

Repair ($)

New Unit ($)

HEAR Credit

## Which CPSC safety recalls match Keystone equipment?

Active U.S. Consumer Product Safety Commission notices mentioning Keystone; verify serial eligibility on CPSC.gov before paying out-of-warranty dispatch charges.

- [**07577** (2007-09-12)](https://lamcoewp.com/recalls/07577-keystone-manufacturing-co-and-qvc-recall-convec/) — Keystone Manufacturing Co. and QVC Recall Convection Ovens with Rotisserie Due to Fire and Electrical Shock Hazards

## FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

### How much electricity does the Keystone KSTAW08I draw each year?

EPA ENERGY STAR lists Keystone KSTAW08I at 400 kWh/yr, producing an estimated utility outlay of $72.64/yr ($726 over 10 years) at the U.S. EIA residential benchmark of 18.16 cents/kWh across 1 finish SKUs.

### How does Keystone KSTAW08I compare against the federal limit?

Against the 10 CFR 430 certified, this Keystone room air conditioner ranks #85 among 560 certified room air conditioners — -132 kWh/yr (-24.8%) vs the 531.9 kWh/yr median.

### When is repairing Keystone KSTAW08I out of warranty NOT worthwhile?

Avoid major mechanical or control-board repairs once Keystone KSTAW08I passes 5.0 years (half its 10-year NAHB lifespan) or whenever a technician quote reaches 50% of net replacement cost.

### Who should NOT install the Keystone KSTAW08I room air conditioner?

Do not specify Keystone KSTAW08I (8000.0 BTU/hr) for commercial duty cycles, tight alcoves that cannot clear 19.2 × 13.5 × 22.0 in plus ventilation gaps, or inside an active year-1 manufacturer warranty period.

### Which SKU trims map to the Keystone KSTAW08I appliance models?

CodeBench merges 1 finish code, led by KSTAW08INV, under KSTAW08I because color suffixes share identical core power draw, 8000.0 BTU/hr volume, and outer cabinet dimensions.

### What safety rules govern Keystone KSTAW08I repairs?

Always shut off the electrical breaker and water shutoff valve before opening KSTAW08I service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

### How do 5 peer alternatives match up to Keystone KSTAW08I?

The peer table compares 5 room air conditioners selected closest to KSTAW08I by cutout width, 8000.0 BTU/hr capacity, and 400 kWh/yr rating so homeowners can evaluate direct drop-in replacements.

### How do you verify the build age of Keystone KSTAW08I?

Check the interior serial sticker with the Keystone serial date guide rather than relying only on the 2024 catalog release year, especially when 10-year codes repeat.

## Related guides

-  [ All Brand Serial Guides  ](https://lamcoewp.com/serial-decoder/)
-  [ Keystone Brand Profile  ](https://lamcoewp.com/brands/keystone/)
-  [ Compare Repair Quote vs HEAR Replacement Net Cost  ](https://lamcoewp.com/tools/repair-vs-replace/)
-  [ Midea MAW08V1QWT (400 kWh)  ](https://lamcoewp.com/models/room-ac/midea/maw08v1qwt/)
-  [ Midea MAW08V1UWT (400 kWh)  ](https://lamcoewp.com/models/room-ac/midea/maw08v1uwt/)
-  [ Midea MAW08W1QWT (400 kWh)  ](https://lamcoewp.com/models/room-ac/midea/maw08w1qwt/)

## Sources

1. [ENERGY STAR Certified Room Air Conditioners Dataset (5xn2-dv4h)](https://data.energystar.gov/resource/5xn2-dv4h.json) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
2. [Study of Life Expectancy of Home Components](https://www.nahb.org/) — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
3. [Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)
4. [CPSC Recalls REST Web Services API (SaferProducts.gov)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), REST JSON 2026 (retrieved 2026-11-23)