# ACIQ AES80 Ventilating Fan Specs

Verified EPA ENERGY STAR test logs for ACIQ AES80 list Fan Efficacy 4.7 CFM/W and 80.0 CFM, giving this upper-half efficiency Bathroom/Utility Room unit clear cost separation at +0.1 CFM/W (+2.2%) relative to the 4.6 CFM/W median. Built into a standard residential footprint, the assembly covers single SKU AES80. Cumulative power cost runs rated service expectations across a 15-year NAHB lifespan while holding ENERGY STAR certified vs 10 CFR 430.

- **Rated Energy** : Ventilating Fans

- **EIA Annual Cost** : Not listed

- **Category Rank** : #422 of 900

- **Capacity** : 80.0 CFM

- **NAHB Lifespan** : 15 years

[All Brand Serial Guides](https://lamcoewp.com/serial-decoder/) [ACIQ Brand Profile](https://lamcoewp.com/brands/aciq/) [All Ventilating Fans (900)](https://lamcoewp.com/models/vent-fan/)

Annual Energy Draw Certified Rank #422 / 900 (tied with 26 at 4.7 CFM/W)

vs Ventilating Fans Median +0.1 CFM/W (+2.2%) EPA certified comparison

Federal Metric (Fan Efficacy) 4.7 CFM/W 10 CFR 430 certified

Est. Operating Cost Unrated Annual kWh not listed

## What are the official specs and computed benchmarks for ACIQ AES80?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.

ACIQ AES80 — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)

| Specification / Metric | AES80 Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| **Capacity** | 80.0 CFM [[U.S. Environmental Protection Agency (ENERGY STAR)]](https://data.energystar.gov/resource/8dv7-nngq.json) | Standard CFM rating | Density unavailable |
| **Listing & Release** | Released 2024 | 1 SKU | Single model listing (1 SKU) |
| **NAHB Service Life** | 15 years [[National Association of Home Builders (NAHB)]](https://www.nahb.org/) | 50% age gate: 7.5 yrs | Evaluate repair vs net replacement once age passes 9.8 yrs |
| **Fan Efficacy** | 4.7 CFM/W | Bathroom/Utility Room | 4.00 inch diameter |

## Which ventilating fans match AES80 in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Ventilating Fans (Matched by Width & kWh Draw)

| Peer Model | Subtype | kWh/yr | Delta vs AES80 | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| [**AERO PURE ABF80G15**](https://lamcoewp.com/models/vent-fan/aero-pure/abf80g15/) | Bathroom/Utility Room | Not listed | Not listed | 80.0 CFM | Not listed | 1 |
| [**AERO PURE ABF80G16**](https://lamcoewp.com/models/vent-fan/aero-pure/abf80g16/) | Bathroom/Utility Room | Not listed | Not listed | 80.0 CFM | Not listed | 1 |
| [**Air King AK80LS6**](https://lamcoewp.com/models/vent-fan/air-king/ak80ls6/) | Bathroom/Utility Room | Not listed | Not listed | 80.0 CFM | Not listed | 2 |
| [**AUPU AV08A1**](https://lamcoewp.com/models/vent-fan/aupu/av08a1/) | Bathroom/Utility Room | Not listed | Not listed | 80.0 CFM | Not listed | 1 |
| [**Broan QTXEG080**](https://lamcoewp.com/models/vent-fan/broan/qtxeg080/) | Bathroom/Utility Room | Not listed | Not listed | 80.0 CFM | Not listed | 1 |

## Does AES80 carry R-600a, duct, or installation boundaries?

AES80 (Bathroom/Utility Room, 4.7 CFM/W) vents humid indoor air outdoors via 4.00 inch diameter (never terminate into an enclosed attic).

Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.

- AES80

## Should you repair AES80 or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

Age (yrs)

Repair ($)

New Unit ($)

HEAR Credit

## FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

### What annual electricity outlay should ACIQ AES80 owners budget?

Rated at certified ENERGY STAR status, ACIQ AES80 averages scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) under EIA's 18.16 cents/kWh U.S. average over 15 years of NAHB service life.

### Where does ACIQ AES80 sit among 900 certified peers?

Out of 900 U.S. certified ventilating fans, ACIQ AES80 ranks #422 — Rank #422 / 900 (tied with 26 at 4.7 CFM/W) — against 10 CFR 430 certified.

### Should owners repair a failing ACIQ AES80 past 15 years?

NAHB places median ventilating fan service life at 15 years; past 7.5 years, estimates exceeding 50% of net new price (after $150 5-yr savings) favor replacement.

### Who is ACIQ AES80 NOT designed for?

Commercial establishments, alcoves smaller than OEM cutout blueprint, and households requiring different capacity than 80.0 CFM should review peer alternatives above.

### Which model numbers belong to the ACIQ AES80 platform?

All 1 finish code maps to the identical AES80 platform, notably AES80: certified ENERGY STAR status vs 0.0 kWh/yr category median.

### What safety checks precede opening ACIQ AES80 housings?

Always shut off the electrical breaker and water shutoff valve before opening AES80 service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

### How does ACIQ AES80 fit standard residential cutouts?

Measuring OEM cutout blueprint at 80.0 CFM, AES80 aligns closely with the 5 nearest peer ventilating fans ranked in the alternative table above.

### Can you date ACIQ AES80 if purchase paperwork is missing?

Yes; check the cabinet serial tag in our ACIQ serial decoder to confirm manufacture year and out-of-warranty status.

## Related guides

-  [ All Brand Serial Guides  ](https://lamcoewp.com/serial-decoder/)
-  [ ACIQ Brand Profile  ](https://lamcoewp.com/brands/aciq/)
-  [ Compare Repair Quote vs HEAR Replacement Net Cost  ](https://lamcoewp.com/tools/repair-vs-replace/)
-  [ AUPU AV08A1 Specs  ](https://lamcoewp.com/models/vent-fan/aupu/av08a1/)
-  [ Broan QTXEG110 Specs  ](https://lamcoewp.com/models/vent-fan/broan/qtxeg110/)
-  [ Broan QTXEG110X = QTXEGH WITH QTXEG110FX Specs  ](https://lamcoewp.com/models/vent-fan/broan/qtxeg110x-qtxegh-with-qtxeg110fx/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
2. [Study of Life Expectancy of Home Components](https://www.nahb.org/) — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
3. [Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)