---
title: "AUPU V4-10HL1 (Ventilating Fans, #177)"
url: https://lamcoewp.com/models/vent-fan/aupu/v4-10hl1/
description: "AUPU V4-10HL1 (100.0 CFM, Ventilating Fans, rank #177 of 900 ventilating fans) with 5 peer models. Compare verified federal data, licensing rules, and."
---

Ventilating Fans · Rank #177 of 900

# AUPU V4-10HL1 Ventilating Fan Specs

Specified at 100.0 CFM and Fan Efficacy 9.5 CFM/W, AUPU V4-10HL1 #177 / 900 — tied with 10 peers, scores higher efficiency than 79.2% of 900 ventilating fans in the U.S. ENERGY STAR directory. Shared internal engineering unites single SKU V4-10HL1 within a standard residential footprint. Evaluated over a 15-year NAHB benchmark service window, operating power equals rated service expectations across a 15-year NAHB lifespan with ENERGY STAR certified margin under DOE 10 CFR 430.

- **Rated Energy** : Ventilating Fans

- **EIA Annual Cost** : Not listed

- **Category Rank** : #177 of 900

- **Capacity** : 100.0 CFM

- **NAHB Lifespan** : 15 years

[All Brand Serial Guides](https://lamcoewp.com/serial-decoder/) [AUPU Brand Profile](https://lamcoewp.com/brands/aupu/) [All Ventilating Fans (900)](https://lamcoewp.com/models/vent-fan/)

Annual Energy Draw Certified Rank #177 / 900 (tied with 10 at 9.5 CFM/W)

vs Ventilating Fans Median +4.9 CFM/W (+106.5%) EPA certified comparison

Federal Metric (Fan Efficacy) 9.5 CFM/W 10 CFR 430 certified

Est. Operating Cost Unrated Annual kWh not listed

## What are the official specs and computed benchmarks for AUPU V4-10HL1?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.

AUPU V4-10HL1 — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)

| Specification / Metric | V4-10HL1 Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| **Capacity** | 100.0 CFM [[U.S. Environmental Protection Agency (ENERGY STAR)]](https://data.energystar.gov/resource/8dv7-nngq.json) | Standard CFM rating | Density unavailable |
| **Listing & Release** | Released 2026 | 1 SKU | Single model listing (1 SKU) |
| **NAHB Service Life** | 15 years [[National Association of Home Builders (NAHB)]](https://www.nahb.org/) | 50% age gate: 7.5 yrs | Evaluate repair vs net replacement once age passes 9.8 yrs |
| **Fan Efficacy** | 9.5 CFM/W | Bathroom/Utility Room | 4.00 inch diameter |

## Which ventilating fans match V4-10HL1 in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Ventilating Fans (Matched by Width & kWh Draw)

| Peer Model | Subtype | kWh/yr | Delta vs V4-10HL1 | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| [**Greenheck SP-LP0810WL**](https://lamcoewp.com/models/vent-fan/greenheck/sp-lp0810wl/) | Bathroom/Utility Room | Not listed | Not listed | 100.0 CFM | Not listed | 1 |
| [**Venco SP-LP0810WL**](https://lamcoewp.com/models/vent-fan/venco/sp-lp0810wl/) | Bathroom/Utility Room | Not listed | Not listed | 100.0 CFM | Not listed | 1 |
| [**Venco VQ-LP0810WL**](https://lamcoewp.com/models/vent-fan/venco/vq-lp0810wl/) | Bathroom/Utility Room | Not listed | Not listed | 100.0 CFM | Not listed | 1 |
| [**Air King SF5810**](https://lamcoewp.com/models/vent-fan/air-king/sf5810/) | Bathroom/Utility Room | Not listed | Not listed | 100.0 CFM | Not listed | 1 |
| [**Akicon AK18CL1-**](https://lamcoewp.com/models/vent-fan/akicon/ak18cl1/) | Bathroom/Utility Room | Not listed | Not listed | 100.0 CFM | Not listed | 3 |

## Does V4-10HL1 carry R-600a, duct, or installation boundaries?

V4-10HL1 (Bathroom/Utility Room, 9.5 CFM/W) vents humid indoor air outdoors via 4.00 inch diameter (never terminate into an enclosed attic).

Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.

- V4-10HL1

## Should you repair V4-10HL1 or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

Age (yrs)

Repair ($)

New Unit ($)

HEAR Credit

## FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

### How much does running AUPU V4-10HL1 cost each year?

At 18.16 cents/kWh (EIA August 2026), AUPU V4-10HL1 draws certified ENERGY STAR status, equating to scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) across all 1 finish trim, specifically V4-10HL1.

### How efficient is AUPU V4-10HL1 compared with federal ceilings?

Measured against 10 CFR 430 certified, AUPU V4-10HL1 holds rank #177 out of 900 U.S. ENERGY STAR ventilating fans: +4.9 CFM/W (+106.5%) vs median 0.0 kWh/yr.

### Which minor parts are exceptions to replacing AUPU V4-10HL1?

Routine wear items such as gaskets, lint filters, coin traps, or inlet mesh remain worthwhile past 7.5 years, whereas motor or board quotes above 50% net replacement favor replacement.

### When is AUPU V4-10HL1 a poor match for a remodel?

Avoid AUPU V4-10HL1 if 100.0 CFM falls short of household demand, if hookups conflict with OEM cutout blueprint, or if local electricity tariffs justify the lowest-kWh quartile.

### Do all variants in the AUPU V4-10HL1 line use identical energy?

Yes; every listed finish — including V4-10HL1 — shares the identical certified ENERGY STAR status ENERGY STAR test rating and 100.0 CFM volume.

### What safety codes restrict AUPU V4-10HL1 disassembly?

Always shut off the electrical breaker and water shutoff valve before opening V4-10HL1 service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

### How should owners confirm cutout clearance for AUPU V4-10HL1?

Verify width, height, and depth against OEM cutout blueprint, leaving extra rear space for cords, hoses, or condenser airflow.

### Where is the serial tag located on AUPU V4-10HL1?

Inspect the inner liner wall, door rim, or tub flange via the AUPU serial guide to decode build month and year before buying replacement assemblies.

## Related guides

-  [ All Brand Serial Guides  ](https://lamcoewp.com/serial-decoder/)
-  [ AUPU Brand Profile  ](https://lamcoewp.com/brands/aupu/)
-  [ Compare Repair Quote vs HEAR Replacement Net Cost  ](https://lamcoewp.com/tools/repair-vs-replace/)
-  [ Greenheck SP-LP0511 Specs  ](https://lamcoewp.com/models/vent-fan/greenheck/sp-lp0511/)
-  [ Revent RVSS80100 Specs  ](https://lamcoewp.com/models/vent-fan/revent/rvss80100/)
-  [ Delta SIG80-110DL Specs  ](https://lamcoewp.com/models/vent-fan/delta/sig80-110dl/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
2. [Study of Life Expectancy of Home Components](https://www.nahb.org/) — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
3. [Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)
