# Delta SIG80-110 Ventilating Fan Specs

Delta SIG80-110 (Bathroom/Utility Room) places #22 of 900 certified U.S. ventilating fans with Fan Efficacy 15.3 CFM/W and 110.0 CFM. Sized for a standard residential footprint, this chassis consolidates 8 finish SKUs including SIG80-110, SIG80-110D, SIG80-110H, SIG80-110MH to prevent duplicate parts lookup. Projected electricity totals rated service expectations across a 15-year NAHB lifespan at August 2026 EIA rates, keeping ENERGY STAR certified headroom under federal 10 CFR 430 rules.

- **Rated Energy** : Ventilating Fans

- **EIA Annual Cost** : Not listed

- **Category Rank** : #22 of 900

- **Capacity** : 110.0 CFM

- **NAHB Lifespan** : 15 years

[All Brand Serial Guides](https://lamcoewp.com/serial-decoder/) [Delta Brand Profile](https://lamcoewp.com/brands/delta/) [All Ventilating Fans (900)](https://lamcoewp.com/models/vent-fan/)

Annual Energy Draw Certified Rank #22 / 900 (top 2.4%)

vs Ventilating Fans Median +10.7 CFM/W (+232.6%) EPA certified comparison

Federal Metric (Fan Efficacy) 15.3 CFM/W 10 CFR 430 certified

Est. Operating Cost Unrated Annual kWh not listed

## What are the official specs and computed benchmarks for Delta SIG80-110?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.

Delta SIG80-110 — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)

| Specification / Metric | SIG80-110 Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| **Capacity** | 110.0 CFM [[U.S. Environmental Protection Agency (ENERGY STAR)]](https://data.energystar.gov/resource/8dv7-nngq.json) | Standard CFM rating | Density unavailable |
| **Listing & Release** | Released 2018 | 8 SKUs | Consolidates 8 finish variants |
| **NAHB Service Life** | 15 years [[National Association of Home Builders (NAHB)]](https://www.nahb.org/) | 50% age gate: 7.5 yrs | Evaluate repair vs net replacement once age passes 9.8 yrs |
| **Fan Efficacy** | 15.3 CFM/W | Bathroom/Utility Room | 6 inch diameter |

## Which ventilating fans match SIG80-110 in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Ventilating Fans (Matched by Width & kWh Draw)

| Peer Model | Subtype | kWh/yr | Delta vs SIG80-110 | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| [**Panasonic FV-0511VKSL3**](https://lamcoewp.com/models/vent-fan/panasonic/fv-0511vksl3/) | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 4 |
| [**Broan-Nutone PTE511R**](https://lamcoewp.com/models/vent-fan/broan-nutone/pte511r/) | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 2 |
| [**Broan-Nutone PTE511RK = PTE511H WITH PTE511RKF**](https://lamcoewp.com/models/vent-fan/broan-nutone/pte511rk-pte511h-with-pte511rkf/) | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 2 |
| [**Broan PTE511RKY**](https://lamcoewp.com/models/vent-fan/broan/pte511rky/) | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 2 |
| [**Broan ZB110HL1**](https://lamcoewp.com/models/vent-fan/broan/zb110hl1/) | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 1 |

## Does SIG80-110 carry R-600a, duct, or installation boundaries?

SIG80-110 (Bathroom/Utility Room, 15.3 CFM/W) vents humid indoor air outdoors via 6 inch diameter (never terminate into an enclosed attic).

Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.

- SIG80-110
- SIG80-110D
- SIG80-110H
- SIG80-110MH

## Should you repair SIG80-110 or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

Age (yrs)

Repair ($)

New Unit ($)

HEAR Credit

## FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

### How much does running Delta SIG80-110 cost each year?

At 18.16 cents/kWh (EIA August 2026), Delta SIG80-110 draws certified ENERGY STAR status, equating to scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) across all 8 finish trims, specifically SIG80-110, SIG80-110D, SIG80-110H, SIG80-110MH.

### How efficient is Delta SIG80-110 compared with federal ceilings?

Measured against 10 CFR 430 certified, Delta SIG80-110 holds rank #22 out of 900 U.S. ENERGY STAR ventilating fans: +10.7 CFM/W (+232.6%) vs median 0.0 kWh/yr.

### Which minor parts are exceptions to replacing Delta SIG80-110?

Routine wear items such as gaskets, lint filters, coin traps, or inlet mesh remain worthwhile past 7.5 years, whereas motor or board quotes above 50% net replacement favor replacement.

### When is Delta SIG80-110 a poor match for a remodel?

Avoid Delta SIG80-110 if 110.0 CFM falls short of household demand, if hookups conflict with OEM cutout blueprint, or if local electricity tariffs justify the lowest-kWh quartile.

### Do all variants in the Delta SIG80-110 line use identical energy?

Yes; every listed finish — including SIG80-110, SIG80-110D, SIG80-110H, SIG80-110MH — shares the identical certified ENERGY STAR status ENERGY STAR test rating and 110.0 CFM volume.

### What safety codes restrict Delta SIG80-110 disassembly?

Always shut off the electrical breaker and water shutoff valve before opening SIG80-110 service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

### How should owners confirm cutout clearance for Delta SIG80-110?

Verify width, height, and depth against OEM cutout blueprint, leaving extra rear space for cords, hoses, or condenser airflow.

### Where is the serial tag located on Delta SIG80-110?

Inspect the inner liner wall, door rim, or tub flange via the Delta serial guide to decode build month and year before buying replacement assemblies.

## Related guides

-  [ All Brand Serial Guides  ](https://lamcoewp.com/serial-decoder/)
-  [ Delta Brand Profile  ](https://lamcoewp.com/brands/delta/)
-  [ Compare Repair Quote vs HEAR Replacement Net Cost  ](https://lamcoewp.com/tools/repair-vs-replace/)
-  [ Broan-Nutone PTE511RK = PTE511H WITH PTE511RKF Specs  ](https://lamcoewp.com/models/vent-fan/broan-nutone/pte511rk-pte511h-with-pte511rkf/)
-  [ S and P PCD80XHP Specs  ](https://lamcoewp.com/models/vent-fan/s-p/pcd80xhp/)
-  [ Broan XB110=XB000HWITHXB110F Specs  ](https://lamcoewp.com/models/vent-fan/broan/xb110-xb000hwithxb110f/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
2. [Study of Life Expectancy of Home Components](https://www.nahb.org/) — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
3. [Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)