title: "Fantech SFC50-80-100H (484308) (Ventilating Fans, #191)"
url: https://lamcoewp.com/models/vent-fan/fantech/sfc50-80-100h-484308/
description: "Fantech SFC50-80-100H (484308) (100.0 CFM, Ventilating Fans, rank #191 of 900 ventilating fans) with 5 peer models. Compare verified federal data, licensing."
---

Ventilating Fans · Rank #191 of 900

# Fantech SFC50-80-100H (484308) Ventilating Fan Specs

For out-of-warranty owners diagnosing Fantech SFC50-80-100H (484308), EPA ENERGY STAR records Fan Efficacy 9.3 CFM/W and 100.0 CFM across single SKU SFC50-80-100H (484308). This Bathroom/Utility Room appliance installs into a standard residential footprint and carries a 15-year NAHB median expectancy. Estimated cumulative utility draw reaches rated service expectations across a 15-year NAHB lifespan at EIA 18.16 cents/kWh, maintaining ENERGY STAR certified under 10 CFR 430.

- **Rated Energy** : Ventilating Fans

- **EIA Annual Cost** : Not listed

- **Category Rank** : #191 of 900

- **Capacity** : 100.0 CFM

- **NAHB Lifespan** : 15 years

[All Brand Serial Guides](https://lamcoewp.com/serial-decoder/) [Fantech Brand Profile](https://lamcoewp.com/brands/fantech/) [All Ventilating Fans (900)](https://lamcoewp.com/models/vent-fan/)

Annual Energy Draw Certified Rank #191 / 900 (tied with 16 at 9.3 CFM/W)

vs Ventilating Fans Median +4.7 CFM/W (+102.2%) EPA certified comparison

Federal Metric (Fan Efficacy) 9.3 CFM/W 10 CFR 430 certified

Est. Operating Cost Unrated Annual kWh not listed

## What are the official specs and computed benchmarks for Fantech SFC50-80-100H (484308)?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.

Fantech SFC50-80-100H (484308) — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)

| Specification / Metric | SFC50-80-100H (484308) Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| **Capacity** | 100.0 CFM [[U.S. Environmental Protection Agency (ENERGY STAR)]](https://data.energystar.gov/resource/8dv7-nngq.json) | Standard CFM rating | Density unavailable |
| **Listing & Release** | Released 2023 | 1 SKU | Single model listing (1 SKU) |
| **NAHB Service Life** | 15 years [[National Association of Home Builders (NAHB)]](https://www.nahb.org/) | 50% age gate: 7.5 yrs | Evaluate repair vs net replacement once age passes 9.8 yrs |
| **Fan Efficacy** | 9.3 CFM/W | Bathroom/Utility Room | 4.00 inch diameter |

## Which ventilating fans match SFC50-80-100H (484308) in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Ventilating Fans (Matched by Width & kWh Draw)

| Peer Model | Subtype | kWh/yr | Delta vs SFC50-80-100H (484308) | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| [**ACIQ AESD100-3**](https://lamcoewp.com/models/vent-fan/aciq/aesd100-3/) | Bathroom/Utility Room | Not listed | Not listed | 100.0 CFM | Not listed | 1 |
| [**Ortech ODDSS-100-3**](https://lamcoewp.com/models/vent-fan/ortech/oddss-100-3/) | Bathroom/Utility Room | Not listed | Not listed | 100.0 CFM | Not listed | 2 |
| [**QuFresh SL100-3**](https://lamcoewp.com/models/vent-fan/qufresh/sl100-3/) | Bathroom/Utility Room | Not listed | Not listed | 100.0 CFM | Not listed | 1 |
| [**S&P PCLPD100XHP**](https://lamcoewp.com/models/vent-fan/s-p/pclpd100xhp/) | Bathroom/Utility Room | Not listed | Not listed | 100.0 CFM | Not listed | 1 |
| [**Revent RVSS80100**](https://lamcoewp.com/models/vent-fan/revent/rvss80100/) | Bathroom/Utility Room | Not listed | Not listed | 100.0 CFM | Not listed | 1 |

## Does SFC50-80-100H (484308) carry R-600a, duct, or installation boundaries?

SFC50-80-100H (484308) (Bathroom/Utility Room, 9.3 CFM/W) vents humid indoor air outdoors via 4.00 inch diameter (never terminate into an enclosed attic).

Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.

- SFC50-80-100H (484308)

## Should you repair SFC50-80-100H (484308) or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

Age (yrs)

Repair ($)

New Unit ($)

HEAR Credit

## FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

### What annual electricity outlay should Fantech SFC50-80-100H (484308) owners budget?

Rated at certified ENERGY STAR status, Fantech SFC50-80-100H (484308) averages scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) under EIA's 18.16 cents/kWh U.S. average over 15 years of NAHB service life.

### Where does Fantech SFC50-80-100H (484308) sit among 900 certified peers?

Out of 900 U.S. certified ventilating fans, Fantech SFC50-80-100H (484308) ranks #191 — Rank #191 / 900 (tied with 16 at 9.3 CFM/W) — against 10 CFR 430 certified.

### Should owners repair a failing Fantech SFC50-80-100H (484308) past 15 years?

NAHB places median ventilating fan service life at 15 years; past 7.5 years, estimates exceeding 50% of net new price (after $150 5-yr savings) favor replacement.

### Who is Fantech SFC50-80-100H (484308) NOT designed for?

Commercial establishments, alcoves smaller than OEM cutout blueprint, and households requiring different capacity than 100.0 CFM should review peer alternatives above.

### Which model numbers belong to the Fantech SFC50-80-100H (484308) platform?

All 1 finish code maps to the identical SFC50-80-100H (484308) platform, notably SFC50-80-100H (484308): certified ENERGY STAR status vs 0.0 kWh/yr category median.

### What safety checks precede opening Fantech SFC50-80-100H (484308) housings?

Always shut off the electrical breaker and water shutoff valve before opening SFC50-80-100H (484308) service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

### How does Fantech SFC50-80-100H (484308) fit standard residential cutouts?

Measuring OEM cutout blueprint at 100.0 CFM, SFC50-80-100H (484308) aligns closely with the 5 nearest peer ventilating fans ranked in the alternative table above.

### Can you date Fantech SFC50-80-100H (484308) if purchase paperwork is missing?

Yes; check the cabinet serial tag in our Fantech serial decoder to confirm manufacture year and out-of-warranty status.

## Related guides

-  [ All Brand Serial Guides  ](https://lamcoewp.com/serial-decoder/)
-  [ Fantech Brand Profile  ](https://lamcoewp.com/brands/fantech/)
-  [ Compare Repair Quote vs HEAR Replacement Net Cost  ](https://lamcoewp.com/tools/repair-vs-replace/)
-  [ Fantech SFC50-80-100LH (484311) Specs  ](https://lamcoewp.com/models/vent-fan/fantech/sfc50-80-100lh-484311/)
-  [ Panasonic RG-S80L Specs  ](https://lamcoewp.com/models/vent-fan/panasonic/rg-s80l/)
-  [ Delta ELT80-110DL Specs  ](https://lamcoewp.com/models/vent-fan/delta/elt80-110dl-2/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
2. [Study of Life Expectancy of Home Components](https://www.nahb.org/) — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
3. [Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)