title: "Fantech SFC50-80-100L (484310) (Ventilating Fans, #191)"
url: https://lamcoewp.com/models/vent-fan/fantech/sfc50-80-100l-484310/
description: "Fantech SFC50-80-100L (484310) (100.0 CFM, Ventilating Fans, rank #191 of 900 ventilating fans) with 5 peer models. Compare verified federal data, licensing."
---

Ventilating Fans · Rank #191 of 900

# Fantech SFC50-80-100L (484310) Ventilating Fan Specs

Fantech SFC50-80-100L (484310) (Bathroom/Utility Room) places #191 of 900 certified U.S. ventilating fans with Fan Efficacy 9.3 CFM/W and 100.0 CFM. Sized for a standard residential footprint, this chassis consolidates single SKU SFC50-80-100L (484310) to prevent duplicate parts lookup. Projected electricity totals rated service expectations across a 15-year NAHB lifespan at August 2026 EIA rates, keeping ENERGY STAR certified headroom under federal 10 CFR 430 rules.

- **Rated Energy** : Ventilating Fans

- **EIA Annual Cost** : Not listed

- **Category Rank** : #191 of 900

- **Capacity** : 100.0 CFM

- **NAHB Lifespan** : 15 years

[All Brand Serial Guides](https://lamcoewp.com/serial-decoder/) [Fantech Brand Profile](https://lamcoewp.com/brands/fantech/) [All Ventilating Fans (900)](https://lamcoewp.com/models/vent-fan/)

Annual Energy Draw Certified Rank #191 / 900 (tied with 16 at 9.3 CFM/W)

vs Ventilating Fans Median +4.7 CFM/W (+102.2%) EPA certified comparison

Federal Metric (Fan Efficacy) 9.3 CFM/W 10 CFR 430 certified

Est. Operating Cost Unrated Annual kWh not listed

## What are the official specs and computed benchmarks for Fantech SFC50-80-100L (484310)?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.

Fantech SFC50-80-100L (484310) — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)

| Specification / Metric | SFC50-80-100L (484310) Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| **Capacity** | 100.0 CFM [[U.S. Environmental Protection Agency (ENERGY STAR)]](https://data.energystar.gov/resource/8dv7-nngq.json) | Standard CFM rating | Density unavailable |
| **Listing & Release** | Released 2023 | 1 SKU | Single model listing (1 SKU) |
| **NAHB Service Life** | 15 years [[National Association of Home Builders (NAHB)]](https://www.nahb.org/) | 50% age gate: 7.5 yrs | Evaluate repair vs net replacement once age passes 9.8 yrs |
| **Fan Efficacy** | 9.3 CFM/W | Bathroom/Utility Room | 4.00 inch depth X 0.00 inch width |

## Which ventilating fans match SFC50-80-100L (484310) in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Ventilating Fans (Matched by Width & kWh Draw)

| Peer Model | Subtype | kWh/yr | Delta vs SFC50-80-100L (484310) | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| [**ACIQ AESD100-3**](https://lamcoewp.com/models/vent-fan/aciq/aesd100-3/) | Bathroom/Utility Room | Not listed | Not listed | 100.0 CFM | Not listed | 1 |
| [**Ortech ODDSS-100-3**](https://lamcoewp.com/models/vent-fan/ortech/oddss-100-3/) | Bathroom/Utility Room | Not listed | Not listed | 100.0 CFM | Not listed | 2 |
| [**QuFresh SL100-3**](https://lamcoewp.com/models/vent-fan/qufresh/sl100-3/) | Bathroom/Utility Room | Not listed | Not listed | 100.0 CFM | Not listed | 1 |
| [**S&P PCLPD100XHP**](https://lamcoewp.com/models/vent-fan/s-p/pclpd100xhp/) | Bathroom/Utility Room | Not listed | Not listed | 100.0 CFM | Not listed | 1 |
| [**Revent RVSS80100**](https://lamcoewp.com/models/vent-fan/revent/rvss80100/) | Bathroom/Utility Room | Not listed | Not listed | 100.0 CFM | Not listed | 1 |

## Does SFC50-80-100L (484310) carry R-600a, duct, or installation boundaries?

SFC50-80-100L (484310) (Bathroom/Utility Room, 9.3 CFM/W) vents humid indoor air outdoors via 4.00 inch depth X 0.00 inch width (never terminate into an enclosed attic).

Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.

- SFC50-80-100L (484310)

## Should you repair SFC50-80-100L (484310) or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

Age (yrs)

Repair ($)

New Unit ($)

HEAR Credit

## FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

### How much electricity does the Fantech SFC50-80-100L (484310) draw each year?

EPA ENERGY STAR lists Fantech SFC50-80-100L (484310) at certified ENERGY STAR status, producing an estimated utility outlay of scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) at the U.S. EIA residential benchmark of 18.16 cents/kWh across 1 finish SKUs.

### How does Fantech SFC50-80-100L (484310) compare against the federal limit?

Against the 10 CFR 430 certified, this Fantech ventilating fan ranks #191 among 900 certified ventilating fans — +4.7 CFM/W (+102.2%) vs the 0.0 kWh/yr median.

### When is repairing Fantech SFC50-80-100L (484310) out of warranty NOT worthwhile?

Avoid major mechanical or control-board repairs once Fantech SFC50-80-100L (484310) passes 7.5 years (half its 15-year NAHB lifespan) or whenever a technician quote reaches 50% of net replacement cost.

### Who should NOT install the Fantech SFC50-80-100L (484310) ventilating fan?

Do not specify Fantech SFC50-80-100L (484310) (100.0 CFM) for commercial duty cycles, tight alcoves that cannot clear OEM cutout blueprint plus ventilation gaps, or inside an active year-1 manufacturer warranty period.

### Which SKU trims map to the Fantech SFC50-80-100L (484310) appliance models?

CodeBench merges 1 finish code, led by SFC50-80-100L (484310), under SFC50-80-100L (484310) because color suffixes share identical core power draw, 100.0 CFM volume, and outer cabinet dimensions.

### What safety rules govern Fantech SFC50-80-100L (484310) repairs?

Always shut off the electrical breaker and water shutoff valve before opening SFC50-80-100L (484310) service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

### How do 5 peer alternatives match up to Fantech SFC50-80-100L (484310)?

The peer table compares 5 ventilating fans selected closest to SFC50-80-100L (484310) by cutout width, 100.0 CFM capacity, and certified ENERGY STAR status rating so homeowners can evaluate direct drop-in replacements.

### How do you verify the build age of Fantech SFC50-80-100L (484310)?

Check the interior serial sticker with the Fantech serial date guide rather than relying only on the 2023 catalog release year, especially when 10-year codes repeat.

## Related guides

-  [ All Brand Serial Guides  ](https://lamcoewp.com/serial-decoder/)
-  [ Fantech Brand Profile  ](https://lamcoewp.com/brands/fantech/)
-  [ Compare Repair Quote vs HEAR Replacement Net Cost  ](https://lamcoewp.com/tools/repair-vs-replace/)
-  [ S and P PCLPD100XHP Specs  ](https://lamcoewp.com/models/vent-fan/s-p/pclpd100xhp/)
-  [ Panasonic FV-0510VSAB1 Specs  ](https://lamcoewp.com/models/vent-fan/panasonic/fv-0510vsab1/)
-  [ Delta SIG110 Specs  ](https://lamcoewp.com/models/vent-fan/delta/sig110/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
2. [Study of Life Expectancy of Home Components](https://www.nahb.org/) — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
3. [Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)