---
title: "HomeWerks 7107-03 (Ventilating Fans, #641)"
url: https://lamcoewp.com/models/vent-fan/homewerks-worldwide/7107-03/
description: "HomeWerks 7107-03 (110.0 CFM, Ventilating Fans, rank #641 of 900 ventilating fans) with 5 peer models. Compare verified federal data, licensing rules, and."
---

Ventilating Fans · Rank #641 of 900

# HomeWerks Worldwide 7107-03 Ventilating Fan Specs

Spanning single SKU 7107-03HW, HomeWerks Worldwide 7107-03 logs Fan Efficacy 4.1 CFM/W inside a standard residential footprint built for 110.0 CFM. Out of 900 certified U.S. ventilating fans, this Bathroom/Utility Room model achieves higher-draw: #641 / 900 — tied with 21 peers, scores higher efficiency than 26.4% of 900 ventilating fans. Out-of-warranty owners weighing component quotes face rated service expectations across a 15-year NAHB lifespan and ENERGY STAR certified compliance under 10 CFR 430.

- **Rated Energy** : Ventilating Fans

- **EIA Annual Cost** : Not listed

- **Category Rank** : #641 of 900

- **Capacity** : 110.0 CFM

- **NAHB Lifespan** : 15 years

[All Brand Serial Guides](https://lamcoewp.com/serial-decoder/) [HomeWerks Worldwide Brand Profile](https://lamcoewp.com/brands/homewerks-worldwide/) [All Ventilating Fans (900)](https://lamcoewp.com/models/vent-fan/)

Annual Energy Draw Certified Rank #641 / 900 (tied with 21 at 4.1 CFM/W)

vs Ventilating Fans Median -0.5 CFM/W (-10.9%) EPA certified comparison

Federal Metric (Fan Efficacy) 4.1 CFM/W 10 CFR 430 certified

Est. Operating Cost Unrated Annual kWh not listed

## What are the official specs and computed benchmarks for HomeWerks Worldwide 7107-03?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.

HomeWerks Worldwide 7107-03 — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)

| Specification / Metric | 7107-03 Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| **Capacity** | 110.0 CFM [[U.S. Environmental Protection Agency (ENERGY STAR)]](https://data.energystar.gov/resource/8dv7-nngq.json) | Standard CFM rating | Density unavailable |
| **Listing & Release** | Released 2022 | 1 SKU | Single model listing (1 SKU) |
| **NAHB Service Life** | 15 years [[National Association of Home Builders (NAHB)]](https://www.nahb.org/) | 50% age gate: 7.5 yrs | Evaluate repair vs net replacement once age passes 9.8 yrs |
| **Fan Efficacy** | 4.1 CFM/W | Bathroom/Utility Room | 4.00 inch diameter |

## Which ventilating fans match 7107-03 in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Ventilating Fans (Matched by Width & kWh Draw)

| Peer Model | Subtype | kWh/yr | Delta vs 7107-03 | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| [**Broan AER110RGBL**](https://lamcoewp.com/models/vent-fan/broan/aer110rgbl/) | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 1 |
| [**RAB CEP10**](https://lamcoewp.com/models/vent-fan/rab/cep10/) | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 1 |
| [**RAB CEP10SNL**](https://lamcoewp.com/models/vent-fan/rab/cep10snl/) | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 1 |
| [**Tech Drive TD-BF-07-PLU**](https://lamcoewp.com/models/vent-fan/tech-drive/td-bf-07-plu/) | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 1 |
| [**Tech Drive TD-BF-25L-5CCT(BL)**](https://lamcoewp.com/models/vent-fan/tech-drive/td-bf-25l-5cct-bl/) | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 1 |

## Does 7107-03 carry R-600a, duct, or installation boundaries?

7107-03 (Bathroom/Utility Room, 4.1 CFM/W) vents humid indoor air outdoors via 4.00 inch diameter (never terminate into an enclosed attic).

Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.

- 7107-03HW

## Should you repair 7107-03 or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

Age (yrs)

Repair ($)

New Unit ($)

HEAR Credit

## FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

### How much does running HomeWerks Worldwide 7107-03 cost each year?

At 18.16 cents/kWh (EIA August 2026), HomeWerks Worldwide 7107-03 draws certified ENERGY STAR status, equating to scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) across all 1 finish trim, specifically 7107-03HW.

### How efficient is HomeWerks Worldwide 7107-03 compared with federal ceilings?

Measured against 10 CFR 430 certified, HomeWerks Worldwide 7107-03 holds rank #641 out of 900 U.S. ENERGY STAR ventilating fans: -0.5 CFM/W (-10.9%) vs median 0.0 kWh/yr.

### Which minor parts are exceptions to replacing HomeWerks Worldwide 7107-03?

Routine wear items such as gaskets, lint filters, coin traps, or inlet mesh remain worthwhile past 7.5 years, whereas motor or board quotes above 50% net replacement favor replacement.

### When is HomeWerks Worldwide 7107-03 a poor match for a remodel?

Avoid HomeWerks Worldwide 7107-03 if 110.0 CFM falls short of household demand, if hookups conflict with OEM cutout blueprint, or if local electricity tariffs justify the lowest-kWh quartile.

### Do all variants in the HomeWerks Worldwide 7107-03 line use identical energy?

Yes; every listed finish — including 7107-03HW — shares the identical certified ENERGY STAR status ENERGY STAR test rating and 110.0 CFM volume.

### What safety codes restrict HomeWerks Worldwide 7107-03 disassembly?

Always shut off the electrical breaker and water shutoff valve before opening 7107-03 service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

### How should owners confirm cutout clearance for HomeWerks Worldwide 7107-03?

Verify width, height, and depth against OEM cutout blueprint, leaving extra rear space for cords, hoses, or condenser airflow.

### Where is the serial tag located on HomeWerks Worldwide 7107-03?

Inspect the inner liner wall, door rim, or tub flange via the HomeWerks Worldwide serial guide to decode build month and year before buying replacement assemblies.

## Related guides

-  [ All Brand Serial Guides  ](https://lamcoewp.com/serial-decoder/)
-  [ HomeWerks Worldwide Brand Profile  ](https://lamcoewp.com/brands/homewerks-worldwide/)
-  [ Compare Repair Quote vs HEAR Replacement Net Cost  ](https://lamcoewp.com/tools/repair-vs-replace/)
-  [ HomeWerks 7141-110 Specs  ](https://lamcoewp.com/models/vent-fan/homewerks-worldwide/7141-110/)
-  [ HomeWerks 7141-80 Specs  ](https://lamcoewp.com/models/vent-fan/homewerks-worldwide/7141-80/)
-  [ HomeWerks 7148-110-G4 Specs  ](https://lamcoewp.com/models/vent-fan/homewerks-worldwide/7148-110-g4/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
2. [Study of Life Expectancy of Home Components](https://www.nahb.org/) — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
3. [Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)
