title: "Nutone LPN80=LP80HWITHLPN80F (Ventilating Fans, #766)"
url: https://lamcoewp.com/models/vent-fan/nutone/lpn80-lp80hwithlpn80f-2/
description: "Nutone LPN80=LP80HWITHLPN80F (80.0 CFM, Ventilating Fans, rank #766 of 900 ventilating fans) with 5 peer models. Compare verified federal data, licensing."
---

Ventilating Fans · Rank #766 of 900

# Nutone LPN80=LP80HWITHLPN80F Ventilating Fan Specs

Spanning single SKU LPN80=LP80HwithLPN80F, Nutone LPN80=LP80HWITHLPN80F logs Fan Efficacy 3.7 CFM/W inside a standard residential footprint built for 80.0 CFM. Out of 900 certified U.S. ventilating fans, this Bathroom/Utility Room model achieves higher-draw: #766 / 900 — tied with 23 peers, scores higher efficiency than 12.3% of 900 ventilating fans. Out-of-warranty owners weighing component quotes face rated service expectations across a 15-year NAHB lifespan and ENERGY STAR certified compliance under 10 CFR 430.

- **Rated Energy** : Ventilating Fans

- **EIA Annual Cost** : Not listed

- **Category Rank** : #766 of 900

- **Capacity** : 80.0 CFM

- **NAHB Lifespan** : 15 years

[All Brand Serial Guides](https://lamcoewp.com/serial-decoder/) [Nutone Brand Profile](https://lamcoewp.com/brands/nutone/) [All Ventilating Fans (900)](https://lamcoewp.com/models/vent-fan/)

Annual Energy Draw Certified Rank #766 / 900 (tied with 23 at 3.7 CFM/W)

vs Ventilating Fans Median -0.9 CFM/W (-19.6%) EPA certified comparison

Federal Metric (Fan Efficacy) 3.7 CFM/W 10 CFR 430 certified

Est. Operating Cost Unrated Annual kWh not listed

## What are the official specs and computed benchmarks for Nutone LPN80=LP80HWITHLPN80F?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.

Nutone LPN80=LP80HWITHLPN80F — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)

| Specification / Metric | LPN80=LP80HWITHLPN80F Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| **Capacity** | 80.0 CFM [[U.S. Environmental Protection Agency (ENERGY STAR)]](https://data.energystar.gov/resource/8dv7-nngq.json) | Standard CFM rating | Density unavailable |
| **Listing & Release** | Released 2015 | 1 SKU | Single model listing (1 SKU) |
| **NAHB Service Life** | 15 years [[National Association of Home Builders (NAHB)]](https://www.nahb.org/) | 50% age gate: 7.5 yrs | Evaluate repair vs net replacement once age passes 9.8 yrs |
| **Fan Efficacy** | 3.7 CFM/W | Bathroom/Utility Room | 4 inch diameter |

## Which ventilating fans match LPN80=LP80HWITHLPN80F in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Ventilating Fans (Matched by Width & kWh Draw)

| Peer Model | Subtype | kWh/yr | Delta vs LPN80=LP80HWITHLPN80F | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| [**Broan EZ80**](https://lamcoewp.com/models/vent-fan/broan/ez80-2/) | Bathroom/Utility Room | Not listed | Not listed | 80.0 CFM | Not listed | 1 |
| [**Broan LP80**](https://lamcoewp.com/models/vent-fan/broan/lp80-2/) | Bathroom/Utility Room | Not listed | Not listed | 80.0 CFM | Not listed | 1 |
| [**Broan LP80=LP80HWITHLP80F**](https://lamcoewp.com/models/vent-fan/broan/lp80-lp80hwithlp80f-2/) | Bathroom/Utility Room | Not listed | Not listed | 80.0 CFM | Not listed | 1 |
| [**HomeWerks Worldwide 7141-80-G4**](https://lamcoewp.com/models/vent-fan/homewerks-worldwide/7141-80-g4/) | Bathroom/Utility Room | Not listed | Not listed | 80.0 CFM | Not listed | 1 |
| [**Air King AK80H**](https://lamcoewp.com/models/vent-fan/air-king/ak80h/) | Bathroom/Utility Room | Not listed | Not listed | 80.0 CFM | Not listed | 1 |

## Does LPN80=LP80HWITHLPN80F carry R-600a, duct, or installation boundaries?

LPN80=LP80HWITHLPN80F (Bathroom/Utility Room, 3.7 CFM/W) vents humid indoor air outdoors via 4 inch diameter (never terminate into an enclosed attic).

Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.

- LPN80=LP80HwithLPN80F

## Should you repair LPN80=LP80HWITHLPN80F or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

Age (yrs)

Repair ($)

New Unit ($)

HEAR Credit

## FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

### How much does running Nutone LPN80=LP80HWITHLPN80F cost each year?

At 18.16 cents/kWh (EIA August 2026), Nutone LPN80=LP80HWITHLPN80F draws certified ENERGY STAR status, equating to scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) across all 1 finish trim, specifically LPN80=LP80HwithLPN80F.

### How efficient is Nutone LPN80=LP80HWITHLPN80F compared with federal ceilings?

Measured against 10 CFR 430 certified, Nutone LPN80=LP80HWITHLPN80F holds rank #766 out of 900 U.S. ENERGY STAR ventilating fans: -0.9 CFM/W (-19.6%) vs median 0.0 kWh/yr.

### Which minor parts are exceptions to replacing Nutone LPN80=LP80HWITHLPN80F?

Routine wear items such as gaskets, lint filters, coin traps, or inlet mesh remain worthwhile past 7.5 years, whereas motor or board quotes above 50% net replacement favor replacement.

### When is Nutone LPN80=LP80HWITHLPN80F a poor match for a remodel?

Avoid Nutone LPN80=LP80HWITHLPN80F if 80.0 CFM falls short of household demand, if hookups conflict with OEM cutout blueprint, or if local electricity tariffs justify the lowest-kWh quartile.

### Do all variants in the Nutone LPN80=LP80HWITHLPN80F line use identical energy?

Yes; every listed finish — including LPN80=LP80HwithLPN80F — shares the identical certified ENERGY STAR status ENERGY STAR test rating and 80.0 CFM volume.

### What safety codes restrict Nutone LPN80=LP80HWITHLPN80F disassembly?

Always shut off the electrical breaker and water shutoff valve before opening LPN80=LP80HWITHLPN80F service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

### How should owners confirm cutout clearance for Nutone LPN80=LP80HWITHLPN80F?

Verify width, height, and depth against OEM cutout blueprint, leaving extra rear space for cords, hoses, or condenser airflow.

### Where is the serial tag located on Nutone LPN80=LP80HWITHLPN80F?

Inspect the inner liner wall, door rim, or tub flange via the Nutone serial guide to decode build month and year before buying replacement assemblies.

## Related guides

-  [ All Brand Serial Guides  ](https://lamcoewp.com/serial-decoder/)
-  [ Nutone Brand Profile  ](https://lamcoewp.com/brands/nutone/)
-  [ Compare Repair Quote vs HEAR Replacement Net Cost  ](https://lamcoewp.com/tools/repair-vs-replace/)
-  [ VENTECHLATION BPT13-12EN-T Specs  ](https://lamcoewp.com/models/vent-fan/ventechlation/bpt13-12en-t/)
-  [ Broan-Nutone BE6 = BEH WITH BE6F Specs  ](https://lamcoewp.com/models/vent-fan/broan-nutone/be6-beh-with-be6f/)
-  [ Canarm CP80 Specs  ](https://lamcoewp.com/models/vent-fan/canarm/cp80/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
2. [Study of Life Expectancy of Home Components](https://www.nahb.org/) — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
3. [Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)