# Ortech OD-1209P Ventilating Fan Specs

Verified EPA ENERGY STAR test logs for Ortech OD-1209P list Fan Efficacy 4.3 CFM/W and 120.0 CFM, giving this higher-draw Bathroom/Utility Room unit clear cost separation at -0.3 CFM/W (-6.5%) relative to the 4.6 CFM/W median. Built into a standard residential footprint, the assembly covers single SKU OD-1209PB. Cumulative power cost runs rated service expectations across a 15-year NAHB lifespan while holding ENERGY STAR certified vs 10 CFR 430.

- **Rated Energy** : Ventilating Fans

- **EIA Annual Cost** : Not listed

- **Category Rank** : #562 of 900

- **Capacity** : 120.0 CFM

- **NAHB Lifespan** : 15 years

[All Brand Serial Guides](https://lamcoewp.com/serial-decoder/) [Ortech Brand Profile](https://lamcoewp.com/brands/ortech/) [All Ventilating Fans (900)](https://lamcoewp.com/models/vent-fan/)

Annual Energy Draw Certified Rank #562 / 900 (tied with 44 at 4.3 CFM/W)

vs Ventilating Fans Median -0.3 CFM/W (-6.5%) EPA certified comparison

Federal Metric (Fan Efficacy) 4.3 CFM/W 10 CFR 430 certified

Est. Operating Cost Unrated Annual kWh not listed

## What are the official specs and computed benchmarks for Ortech OD-1209P?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.

Ortech OD-1209P — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)

| Specification / Metric | OD-1209P Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| **Capacity** | 120.0 CFM [[U.S. Environmental Protection Agency (ENERGY STAR)]](https://data.energystar.gov/resource/8dv7-nngq.json) | Standard CFM rating | Density unavailable |
| **Listing & Release** | Released 2022 | 1 SKU | Single model listing (1 SKU) |
| **NAHB Service Life** | 15 years [[National Association of Home Builders (NAHB)]](https://www.nahb.org/) | 50% age gate: 7.5 yrs | Evaluate repair vs net replacement once age passes 9.8 yrs |
| **Fan Efficacy** | 4.3 CFM/W | Bathroom/Utility Room | 6.00 inch diameter |

## Which ventilating fans match OD-1209P in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Ventilating Fans (Matched by Width & kWh Draw)

| Peer Model | Subtype | kWh/yr | Delta vs OD-1209P | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| [**Kaze Appliance SEP120**](https://lamcoewp.com/models/vent-fan/kaze-appliance/sep120/) | Bathroom/Utility Room | Not listed | Not listed | 120.0 CFM | Not listed | 1 |
| [**S&P PC110XP**](https://lamcoewp.com/models/vent-fan/s-p/pc110xp-2/) | Bathroom/Utility Room | Not listed | Not listed | 120.0 CFM | Not listed | 1 |
| [**Greenheck SP-B110**](https://lamcoewp.com/models/vent-fan/greenheck/sp-b110/) | Bathroom/Utility Room | Not listed | Not listed | 118.0 CFM | Not listed | 1 |
| [**Ortech OIF4-140**](https://lamcoewp.com/models/vent-fan/ortech/oif4-140/) | In-line (single-port) | Not listed | Not listed | 120.0 CFM | Not listed | 1 |
| [**Anzzi EF-AZ102**](https://lamcoewp.com/models/vent-fan/anzzi/ef-az102/) | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 1 |

## Does OD-1209P carry R-600a, duct, or installation boundaries?

OD-1209P (Bathroom/Utility Room, 4.3 CFM/W) vents humid indoor air outdoors via 6.00 inch diameter (never terminate into an enclosed attic).

Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.

- OD-1209PB

## Should you repair OD-1209P or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

Age (yrs)

Repair ($)

New Unit ($)

HEAR Credit

## FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

### What annual electricity outlay should Ortech OD-1209P owners budget?

Rated at certified ENERGY STAR status, Ortech OD-1209P averages scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) under EIA's 18.16 cents/kWh U.S. average over 15 years of NAHB service life.

### Where does Ortech OD-1209P sit among 900 certified peers?

Out of 900 U.S. certified ventilating fans, Ortech OD-1209P ranks #562 — Rank #562 / 900 (tied with 44 at 4.3 CFM/W) — against 10 CFR 430 certified.

### Should owners repair a failing Ortech OD-1209P past 15 years?

NAHB places median ventilating fan service life at 15 years; past 7.5 years, estimates exceeding 50% of net new price (after $150 5-yr savings) favor replacement.

### Who is Ortech OD-1209P NOT designed for?

Commercial establishments, alcoves smaller than OEM cutout blueprint, and households requiring different capacity than 120.0 CFM should review peer alternatives above.

### Which model numbers belong to the Ortech OD-1209P platform?

All 1 finish code maps to the identical OD-1209P platform, notably OD-1209PB: certified ENERGY STAR status vs 0.0 kWh/yr category median.

### What safety checks precede opening Ortech OD-1209P housings?

Always shut off the electrical breaker and water shutoff valve before opening OD-1209P service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

### How does Ortech OD-1209P fit standard residential cutouts?

Measuring OEM cutout blueprint at 120.0 CFM, OD-1209P aligns closely with the 5 nearest peer ventilating fans ranked in the alternative table above.

### Can you date Ortech OD-1209P if purchase paperwork is missing?

Yes; check the cabinet serial tag in our Ortech serial decoder to confirm manufacture year and out-of-warranty status.

## Related guides

-  [ All Brand Serial Guides  ](https://lamcoewp.com/serial-decoder/)
-  [ Ortech Brand Profile  ](https://lamcoewp.com/brands/ortech/)
-  [ Compare Repair Quote vs HEAR Replacement Net Cost  ](https://lamcoewp.com/tools/repair-vs-replace/)
-  [ Panasonic FV-07VBA1A+FV-07VBB1 Specs  ](https://lamcoewp.com/models/vent-fan/panasonic/fv-07vba1a-fv-07vbb1/)
-  [ Tech Drive TD-BF-04 Specs  ](https://lamcoewp.com/models/vent-fan/tech-drive/td-bf-04/)
-  [ ACIQ AES100 Specs  ](https://lamcoewp.com/models/vent-fan/aciq/aes100/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
2. [Study of Life Expectancy of Home Components](https://www.nahb.org/) — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
3. [Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)