title: "Ortech ODDSS-100-3 (Ventilating Fans, #191)"
url: https://lamcoewp.com/models/vent-fan/ortech/oddss-100-3/
description: "Ortech ODDSS-100-3 (100.0 CFM, Ventilating Fans, rank #191 of 900 ventilating fans) with 5 peer models. Compare verified federal data, licensing rules, and."
---

Ventilating Fans · Rank #191 of 900

# Ortech ODDSS-100-3 Ventilating Fan Specs

Ortech ODDSS-100-3 (Bathroom/Utility Room) places #191 of 900 certified U.S. ventilating fans with Fan Efficacy 9.3 CFM/W and 100.0 CFM. Sized for a standard residential footprint, this chassis consolidates 2 finish SKUs including ODDSS-100-3, ODDSS-100-3HS to prevent duplicate parts lookup. Projected electricity totals rated service expectations across a 15-year NAHB lifespan at August 2026 EIA rates, keeping ENERGY STAR certified headroom under federal 10 CFR 430 rules.

- **Rated Energy** : Ventilating Fans

- **EIA Annual Cost** : Not listed

- **Category Rank** : #191 of 900

- **Capacity** : 100.0 CFM

- **NAHB Lifespan** : 15 years

[All Brand Serial Guides](https://lamcoewp.com/serial-decoder/) [Ortech Brand Profile](https://lamcoewp.com/brands/ortech/) [All Ventilating Fans (900)](https://lamcoewp.com/models/vent-fan/)

Annual Energy Draw Certified Rank #191 / 900 (tied with 16 at 9.3 CFM/W)

vs Ventilating Fans Median +4.7 CFM/W (+102.2%) EPA certified comparison

Federal Metric (Fan Efficacy) 9.3 CFM/W 10 CFR 430 certified

Est. Operating Cost Unrated Annual kWh not listed

## What are the official specs and computed benchmarks for Ortech ODDSS-100-3?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.

Ortech ODDSS-100-3 — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)

| Specification / Metric | ODDSS-100-3 Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| **Capacity** | 100.0 CFM [[U.S. Environmental Protection Agency (ENERGY STAR)]](https://data.energystar.gov/resource/8dv7-nngq.json) | Standard CFM rating | Density unavailable |
| **Listing & Release** | Released 2024 | 2 SKUs | Consolidates 2 finish variants |
| **NAHB Service Life** | 15 years [[National Association of Home Builders (NAHB)]](https://www.nahb.org/) | 50% age gate: 7.5 yrs | Evaluate repair vs net replacement once age passes 9.8 yrs |
| **Fan Efficacy** | 9.3 CFM/W | Bathroom/Utility Room | 4.00 inch diameter |

## Which ventilating fans match ODDSS-100-3 in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Ventilating Fans (Matched by Width & kWh Draw)

| Peer Model | Subtype | kWh/yr | Delta vs ODDSS-100-3 | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| [**ACIQ AESD100-3**](https://lamcoewp.com/models/vent-fan/aciq/aesd100-3/) | Bathroom/Utility Room | Not listed | Not listed | 100.0 CFM | Not listed | 1 |
| [**Fantech SF50-80-100 (484305)**](https://lamcoewp.com/models/vent-fan/fantech/sf50-80-100-484305/) | Bathroom/Utility Room | Not listed | Not listed | 100.0 CFM | Not listed | 1 |
| [**Fantech SF50-80-100L (484306)**](https://lamcoewp.com/models/vent-fan/fantech/sf50-80-100l-484306/) | Bathroom/Utility Room | Not listed | Not listed | 100.0 CFM | Not listed | 1 |
| [**Fantech SFC50-80-100 (484307)**](https://lamcoewp.com/models/vent-fan/fantech/sfc50-80-100-484307/) | Bathroom/Utility Room | Not listed | Not listed | 100.0 CFM | Not listed | 1 |
| [**Fantech SFC50-80-100H (484308)**](https://lamcoewp.com/models/vent-fan/fantech/sfc50-80-100h-484308/) | Bathroom/Utility Room | Not listed | Not listed | 100.0 CFM | Not listed | 1 |

## Does ODDSS-100-3 carry R-600a, duct, or installation boundaries?

ODDSS-100-3 (Bathroom/Utility Room, 9.3 CFM/W) vents humid indoor air outdoors via 4.00 inch diameter (never terminate into an enclosed attic).

Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.

- ODDSS-100-3
- ODDSS-100-3HS

## Should you repair ODDSS-100-3 or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

Age (yrs)

Repair ($)

New Unit ($)

HEAR Credit

## FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

### How much does running Ortech ODDSS-100-3 cost each year?

At 18.16 cents/kWh (EIA August 2026), Ortech ODDSS-100-3 draws certified ENERGY STAR status, equating to scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) across all 2 finish trims, specifically ODDSS-100-3, ODDSS-100-3HS.

### How efficient is Ortech ODDSS-100-3 compared with federal ceilings?

Measured against 10 CFR 430 certified, Ortech ODDSS-100-3 holds rank #191 out of 900 U.S. ENERGY STAR ventilating fans: +4.7 CFM/W (+102.2%) vs median 0.0 kWh/yr.

### Which minor parts are exceptions to replacing Ortech ODDSS-100-3?

Routine wear items such as gaskets, lint filters, coin traps, or inlet mesh remain worthwhile past 7.5 years, whereas motor or board quotes above 50% net replacement favor replacement.

### When is Ortech ODDSS-100-3 a poor match for a remodel?

Avoid Ortech ODDSS-100-3 if 100.0 CFM falls short of household demand, if hookups conflict with OEM cutout blueprint, or if local electricity tariffs justify the lowest-kWh quartile.

### Do all variants in the Ortech ODDSS-100-3 line use identical energy?

Yes; every listed finish — including ODDSS-100-3, ODDSS-100-3HS — shares the identical certified ENERGY STAR status ENERGY STAR test rating and 100.0 CFM volume.

### What safety codes restrict Ortech ODDSS-100-3 disassembly?

Always shut off the electrical breaker and water shutoff valve before opening ODDSS-100-3 service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

### How should owners confirm cutout clearance for Ortech ODDSS-100-3?

Verify width, height, and depth against OEM cutout blueprint, leaving extra rear space for cords, hoses, or condenser airflow.

### Where is the serial tag located on Ortech ODDSS-100-3?

Inspect the inner liner wall, door rim, or tub flange via the Ortech serial guide to decode build month and year before buying replacement assemblies.

## Related guides

-  [ All Brand Serial Guides  ](https://lamcoewp.com/serial-decoder/)
-  [ Ortech Brand Profile  ](https://lamcoewp.com/brands/ortech/)
-  [ Compare Repair Quote vs HEAR Replacement Net Cost  ](https://lamcoewp.com/tools/repair-vs-replace/)
-  [ Delta ELT80-110HL Specs  ](https://lamcoewp.com/models/vent-fan/delta/elt80-110hl-2/)
-  [ Broan-Nutone LP510R Specs  ](https://lamcoewp.com/models/vent-fan/broan-nutone/lp510r/)
-  [ Delta SIG110 Specs  ](https://lamcoewp.com/models/vent-fan/delta/sig110/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
2. [Study of Life Expectancy of Home Components](https://www.nahb.org/) — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
3. [Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)