---
title: "Zephyr AK8400BS- (Ventilating Fans, #688)"
url: https://lamcoewp.com/models/vent-fan/zephyr/ak8400bs/
description: "Zephyr AK8400BS- (190.0 CFM, Ventilating Fans, rank #688 of 900 ventilating fans) with 5 peer models. Compare verified federal data, licensing rules, and."
---

Ventilating Fans · Rank #688 of 900

# Zephyr AK8400BS- Ventilating Fan Specs

Spanning single SKU AK8400BS-ES, Zephyr AK8400BS- logs Fan Efficacy 3.9 CFM/W inside a standard residential footprint built for 190.0 CFM. Out of 900 certified U.S. ventilating fans, this Range Hood model achieves higher-draw: #688 / 900 — tied with 51 peers, scores higher efficiency than 17.9% of 900 ventilating fans. Out-of-warranty owners weighing component quotes face rated service expectations across a 15-year NAHB lifespan and ENERGY STAR certified compliance under 10 CFR 430.

- **Rated Energy** : Ventilating Fans

- **EIA Annual Cost** : Not listed

- **Category Rank** : #688 of 900

- **Capacity** : 190.0 CFM

- **NAHB Lifespan** : 15 years

[All Brand Serial Guides](https://lamcoewp.com/serial-decoder/) [Zephyr Brand Profile](https://lamcoewp.com/brands/zephyr/) [All Ventilating Fans (900)](https://lamcoewp.com/models/vent-fan/)

Annual Energy Draw Certified Rank #688 / 900 (tied with 51 at 3.9 CFM/W)

vs Ventilating Fans Median -0.7 CFM/W (-15.2%) EPA certified comparison

Federal Metric (Fan Efficacy) 3.9 CFM/W 10 CFR 430 certified

Est. Operating Cost Unrated Annual kWh not listed

## What are the official specs and computed benchmarks for Zephyr AK8400BS-?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.

Zephyr AK8400BS- — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)

| Specification / Metric | AK8400BS- Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| **Capacity** | 190.0 CFM [[U.S. Environmental Protection Agency (ENERGY STAR)]](https://data.energystar.gov/resource/8dv7-nngq.json) | Standard CFM rating | Density unavailable |
| **Listing & Release** | Released 2023 | 1 SKU | Single model listing (1 SKU) |
| **NAHB Service Life** | 15 years [[National Association of Home Builders (NAHB)]](https://www.nahb.org/) | 50% age gate: 7.5 yrs | Evaluate repair vs net replacement once age passes 9.8 yrs |
| **Fan Efficacy** | 3.9 CFM/W | Range Hood | 6.00 inch depth X 0.00 inch width |

## Which ventilating fans match AK8400BS- in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Ventilating Fans (Matched by Width & kWh Draw)

| Peer Model | Subtype | kWh/yr | Delta vs AK8400BS- | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| [**Broan ALT4306**](https://lamcoewp.com/models/vent-fan/broan/alt4306-2/) | Range Hood | Not listed | Not listed | 190.0 CFM | Not listed | 1 |
| [**Broan L200EL**](https://lamcoewp.com/models/vent-fan/broan/l200el/) | In-line (single-port) | Not listed | Not listed | 200.0 CFM | Not listed | 1 |
| [**Zephyr ZSI-E30BS-**](https://lamcoewp.com/models/vent-fan/zephyr/zsi-e30bs/) | Range Hood | Not listed | Not listed | 200.0 CFM | Not listed | 1 |
| [**Zephyr ZSI-E36BS-**](https://lamcoewp.com/models/vent-fan/zephyr/zsi-e36bs/) | Range Hood | Not listed | Not listed | 200.0 CFM | Not listed | 1 |
| [**Dayton 6WZN6**](https://lamcoewp.com/models/vent-fan/dayton/6wzn6/) | In-line (single-port) | Not listed | Not listed | 213.0 CFM | Not listed | 1 |

## Does AK8400BS- carry R-600a, duct, or installation boundaries?

AK8400BS- (Range Hood, 3.9 CFM/W) vents humid indoor air outdoors via 6.00 inch depth X 0.00 inch width (never terminate into an enclosed attic).

Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.

- AK8400BS-ES

## Should you repair AK8400BS- or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

Age (yrs)

Repair ($)

New Unit ($)

HEAR Credit

## FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

### What does Zephyr AK8400BS- consume in kWh and dollars?

EPA data records certified ENERGY STAR status for Zephyr AK8400BS-, costing scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) at 18.16 cents/kWh across 1 consolidated SKU finishes.

### How far below the federal ceiling is Zephyr AK8400BS-?

It posts 10 CFR 430 certified and places #688 of 900 ventilating fans: -0.7 CFM/W (-15.2%) relative to the 0.0 kWh/yr median.

### At what age does Zephyr AK8400BS- fail the 50% repair test?

Past 7.5 years of the 15-year NAHB benchmark, repair bids above half of net replacement minus $150 energy savings generally favor buying new.

### Which buyers should skip Zephyr AK8400BS-?

Skip AK8400BS- if cabinet openings cannot clear OEM cutout blueprint, if 190.0 CFM misses family sizing, or if commercial heavy-use durability is required.

### Are AK8400BS-ES mechanically the same model?

Yes; cosmetic finish trims (1 total SKUs) share identical certified ENERGY STAR status efficiency, 190.0 CFM interior rating, and chassis assemblies.

### Which safety boundaries restrict Zephyr AK8400BS- DIY work?

Always shut off the electrical breaker and water shutoff valve before opening AK8400BS- service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

### Which peer alternatives match Zephyr AK8400BS-?

Review the 5 closest ventilating fans listed above, sorted by OEM cutout blueprint cutout, 190.0 CFM capacity, and annual kWh similarity.

### What checks come before ordering Zephyr AK8400BS- replacement parts?

Decode the serial manufacture year, verify active Zephyr CPSC recalls, and test the repair quote in the 50% estimator above.

## Related guides

-  [ All Brand Serial Guides  ](https://lamcoewp.com/serial-decoder/)
-  [ Zephyr Brand Profile  ](https://lamcoewp.com/brands/zephyr/)
-  [ Compare Repair Quote vs HEAR Replacement Net Cost  ](https://lamcoewp.com/tools/repair-vs-replace/)
-  [ Air King AK100 Specs  ](https://lamcoewp.com/models/vent-fan/air-king/ak100/)
-  [ Air King AK110P Specs  ](https://lamcoewp.com/models/vent-fan/air-king/ak110p/)
-  [ Air King AK80H Specs  ](https://lamcoewp.com/models/vent-fan/air-king/ak80h/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
2. [Study of Life Expectancy of Home Components](https://www.nahb.org/) — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
3. [Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)
