title: "A. O. Smith HPA10-40H45DV 2 (902 kWh/yr, #171)"
url: https://lamcoewp.com/models/water-heater/a-o-smith/hpa10-40h45dv-2/
description: "A. O. Smith HPA10-40H45DV 2 (36.0 gal, 902 kWh/yr, $163.80/yr EIA, rank #171 of 582 water heaters) with 5 peer models. Compare verified federal data."
---

Water Heaters · Rank #171 of 582

# A. O. Smith HPA10-40H45DV 2 Water Heater Specs

A. O. Smith HPA10-40H45DV 2 (Hybrid/Electric Heat Pump) places #171 of 582 certified U.S. water heaters with 902 kWh/yr ($163.80/yr at 18.16c/kWh) and 36.0 gal. Sized for a 24-inch compact alcove, this chassis consolidates single SKU HPA10-40H45DV 2** to prevent duplicate parts lookup. Projected electricity totals $1,638.00 over a 10-year NAHB lifespan at August 2026 EIA rates, keeping ENERGY STAR certified headroom under federal 10 CFR 430 rules.

- **Rated Energy** : 902 kWh/yr

- **EIA Annual Cost** : $163.80/yr

- **Category Rank** : #171 of 582

- **Capacity** : 36.0 gal

- **NAHB Lifespan** : 10 years

[All Brand Serial Guides](https://lamcoewp.com/serial-decoder/) [A. O. Smith Brand Profile](https://lamcoewp.com/brands/a-o-smith/) [All Water Heaters (582)](https://lamcoewp.com/models/water-heater/)

Annual Energy Draw 902 kWh/yr Rank #171 / 582 (tied with 22 at 902 kWh/yr)

vs Water Heaters Median -180 kWh/yr (-16.6%) Median 1,082.0 kWh/yr

Federal Metric (UEF) 3.6 UEF 10 CFR 430 certified

Est. Operating Cost $163.80/yr $1,638 over 10 yr NAHB

## How does HPA10-40H45DV 2 compare across all 582 water heaters?

A. O. Smith HPA10-40H45DV 2 (902 kWh/yr) sits against the water heaters category median of 1,082.0 kWh/yr, -180 kWh/yr (-16.6%), and U.S. 10 CFR 430 baselines.

View quantile summary for Water Heaters — HPA10-40H45DV 2

| Quantile / Marker | Annual kWh/yr |
|---|---|
| Most efficient model | 643 kWh/yr kWh |
| 25th percentile | 883 kWh/yr kWh |
| Category median | 1082 kWh/yr kWh |
| 75th percentile | 1289 kWh/yr kWh |
| Highest rated draw | 1741 kWh/yr kWh |

## Where does HPA10-40H45DV 2 rank in operating-cost percentile?

Ranked #171 of 582 rated water heaters using EIA August 2026 national residential electricity rates (18.16 cents/kWh) over a 10-year NAHB median lifespan.

## What are the official specs and computed benchmarks for A. O. Smith HPA10-40H45DV 2?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (10 years), and estimated operating electricity costs at 18.16 cents/kWh.

A. O. Smith HPA10-40H45DV 2 — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)

| Specification / Metric | HPA10-40H45DV 2 Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| **Rated Energy** | 902 kWh/yr [[U.S. Environmental Protection Agency (ENERGY STAR)]](https://data.energystar.gov/resource/pbpq-swnu.json) | Median 1,082 kWh/yr | Tied with 22 peers at 902 kWh/yr (-180 kWh/yr, -16.6% vs median) |
| **Capacity** | 36.0 gal [[U.S. Environmental Protection Agency (ENERGY STAR)]](https://data.energystar.gov/resource/pbpq-swnu.json) | Standard gal rating | 25.06 kWh/gal (+31.5% vs 19.06 median) |
| **Cutout W × H × D** | 20.0" W × 66.0" H [[U.S. Environmental Protection Agency (ENERGY STAR)]](https://data.energystar.gov/resource/pbpq-swnu.json) | Released 2024 | Single model listing (1 SKU) |
| **Operating Cost (EIA)** | $163.80/yr [[U.S. Energy Information Administration (EIA)]](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) | 18.16 c/kWh US avg | Formula: 902 kWh × $0.1816 = $163.80/yr ($1,638.00 over 10 yrs) |
| **NAHB Service Life** | 10 years [[National Association of Home Builders (NAHB)]](https://www.nahb.org/) | 50% age gate: 5.0 yrs | Evaluate repair vs net replacement once age passes 6.5 yrs |
| **UEF** | 3.6 UEF | Electric | Certified efficiency metric |

## Which water heaters match HPA10-40H45DV 2 in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Water Heaters (Matched by Width & kWh Draw)

| Peer Model | Subtype | kWh/yr | Delta vs HPA10-40H45DV 2 | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| [**American HPA10240H045DV 2**](https://lamcoewp.com/models/water-heater/american/hpa10240h045dv-2/) | Hybrid/Electric Heat Pump | 902 | Same kWh | 36.0 gal | 20.0" W × 66.0" H | 1 |
| [**Lochinvar CHPA-40 2**](https://lamcoewp.com/models/water-heater/lochinvar/chpa-40-2/) | Hybrid/Electric Heat Pump | 902 | Same kWh | 36.0 gal | 20.0" W × 66.0" H | 1 |
| [**Lochinvar HPPA040KD 2**](https://lamcoewp.com/models/water-heater/lochinvar/hppa040kd-2/) | Hybrid/Electric Heat Pump | 902 | Same kWh | 36.0 gal | 20.0" W × 66.0" H | 1 |
| [**RELIANCE WATER HEATERS 10-40-DHPTA 2**](https://lamcoewp.com/models/water-heater/reliance-water-heaters/10-40-dhpta-2/) | Hybrid/Electric Heat Pump | 902 | Same kWh | 36.0 gal | 20.0" W × 66.0" H | 1 |
| [**State CSHP-40 2**](https://lamcoewp.com/models/water-heater/state/cshp-40-2/) | Hybrid/Electric Heat Pump | 902 | Same kWh | 36.0 gal | 20.0" W × 66.0" H | 1 |

## Does HPA10-40H45DV 2 carry R-600a, duct, or installation boundaries?

HPA10-40H45DV 2 (Hybrid/Electric Heat Pump, Electric, UEF 3.6) supplies residential hot water; heat-pump models need ~700 cu ft surrounding air volume.

Verify T&P relief valve discharge piping, thermal expansion tanks, and 240V/gas connections with a licensed plumber or electrician; check $1,750 DOE HEAR heat-pump credits.

- HPA10-40H45DV 2**

## Should you repair HPA10-40H45DV 2 or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

Age (yrs)

Repair ($)

New Unit ($)

HEAR Credit

## FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

### How much does running A. O. Smith HPA10-40H45DV 2 cost each year?

At 18.16 cents/kWh (EIA August 2026), A. O. Smith HPA10-40H45DV 2 draws 902 kWh/yr, equating to $163.80/yr ($1,638 over 10 years) across all 1 finish trim, specifically HPA10-40H45DV 2**.

### How efficient is A. O. Smith HPA10-40H45DV 2 compared with federal ceilings?

Measured against 10 CFR 430 certified, A. O. Smith HPA10-40H45DV 2 holds rank #171 out of 582 U.S. ENERGY STAR water heaters: -180 kWh/yr (-16.6%) vs median 1082.0 kWh/yr.

### Which minor parts are exceptions to replacing A. O. Smith HPA10-40H45DV 2?

Routine wear items such as gaskets, lint filters, coin traps, or inlet mesh remain worthwhile past 5.0 years, whereas motor or board quotes above 50% net replacement favor replacement.

### When is A. O. Smith HPA10-40H45DV 2 a poor match for a remodel?

Avoid A. O. Smith HPA10-40H45DV 2 if 36.0 gal falls short of household demand, if hookups conflict with 20.0" W × 66.0" H, or if local electricity tariffs justify the lowest-kWh quartile.

### Do all variants in the A. O. Smith HPA10-40H45DV 2 line use identical energy?

Yes; every listed finish — including HPA10-40H45DV 2** — shares the identical 902 kWh/yr ENERGY STAR test rating and 36.0 gal volume.

### What safety codes restrict A. O. Smith HPA10-40H45DV 2 disassembly?

Always shut off the electrical breaker and water shutoff valve before opening HPA10-40H45DV 2 service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

### How should owners confirm cutout clearance for A. O. Smith HPA10-40H45DV 2?

Verify width, height, and depth against 20.0" W × 66.0" H, leaving extra rear space for cords, hoses, or condenser airflow.

### Where is the serial tag located on A. O. Smith HPA10-40H45DV 2?

Inspect the inner liner wall, door rim, or tub flange via the A. O. Smith serial guide to decode build month and year before buying replacement assemblies.

## Related guides

-  [ All Brand Serial Guides  ](https://lamcoewp.com/serial-decoder/)
-  [ A. O. Smith Brand Profile  ](https://lamcoewp.com/brands/a-o-smith/)
-  [ Compare Repair Quote vs HEAR Replacement Net Cost  ](https://lamcoewp.com/tools/repair-vs-replace/)
-  [ American HPA10240H045DV 2 (902 kWh)  ](https://lamcoewp.com/models/water-heater/american/hpa10240h045dv-2/)
-  [ Lochinvar HPPA040KD 2 (902 kWh)  ](https://lamcoewp.com/models/water-heater/lochinvar/hppa040kd-2/)
-  [ State CSHP-40 2 (902 kWh)  ](https://lamcoewp.com/models/water-heater/state/cshp-40-2/)

## Sources

1. [ENERGY STAR Certified Residential Water Heaters Dataset (pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
2. [Study of Life Expectancy of Home Components](https://www.nahb.org/) — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
3. [Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)