title: "Richmond 10E50-HP515 (846 kWh/yr, #36)"
url: https://lamcoewp.com/models/water-heater/richmond/10e50-hp515/
description: "Richmond 10E50-HP515 (45.0 gal, 846 kWh/yr, $153.63/yr EIA, rank #36 of 582 water heaters) with 5 peer models. Compare verified federal data, licensing rules."
---

Water Heaters · Rank #36 of 582

# Richmond 10E50-HP515 Water Heater Specs

Designed for a 24-inch compact alcove at 45.0 gal, Richmond 10E50-HP515 draws 846 kWh/yr ($153.63/yr at 18.16c/kWh) and ranks -236 kWh/yr (-21.8%) relative to the 1,082 kWh/yr median among 1,169 certified water heaters. Factory color variants map back to single SKU 10E50-HP515. Pairing ENERGY STAR certified DOE 10 CFR 430 compliance with NAHB median expectancy points to $1,536.30 over a 10-year NAHB lifespan.

- **Rated Energy** : 846 kWh/yr

- **EIA Annual Cost** : $153.63/yr

- **Category Rank** : #36 of 582

- **Capacity** : 45.0 gal

- **NAHB Lifespan** : 10 years

[All Brand Serial Guides](https://lamcoewp.com/serial-decoder/) [Richmond Brand Profile](https://lamcoewp.com/brands/richmond/) [All Water Heaters (582)](https://lamcoewp.com/models/water-heater/)

Annual Energy Draw 846 kWh/yr Rank #36 / 582 (tied with 28 at 846 kWh/yr)

vs Water Heaters Median -236 kWh/yr (-21.8%) Median 1,082.0 kWh/yr

Federal Metric (UEF) 3.75 UEF 10 CFR 430 certified

Est. Operating Cost $153.63/yr $1,536 over 10 yr NAHB

## How does 10E50-HP515 compare across all 582 water heaters?

Richmond 10E50-HP515 (846 kWh/yr) sits against the water heaters category median of 1,082.0 kWh/yr, -236 kWh/yr (-21.8%), and U.S. 10 CFR 430 baselines.

View quantile summary for Water Heaters — 10E50-HP515

| Quantile / Marker | Annual kWh/yr |
|---|---|
| Most efficient model | 643 kWh/yr kWh |
| 25th percentile | 883 kWh/yr kWh |
| Category median | 1082 kWh/yr kWh |
| 75th percentile | 1289 kWh/yr kWh |
| Highest rated draw | 1741 kWh/yr kWh |

## Where does 10E50-HP515 rank in operating-cost percentile?

Ranked #36 of 582 rated water heaters using EIA August 2026 national residential electricity rates (18.16 cents/kWh) over a 10-year NAHB median lifespan.

## What are the official specs and computed benchmarks for Richmond 10E50-HP515?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (10 years), and estimated operating electricity costs at 18.16 cents/kWh.

Richmond 10E50-HP515 — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)

| Specification / Metric | 10E50-HP515 Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| **Rated Energy** | 846 kWh/yr [[U.S. Environmental Protection Agency (ENERGY STAR)]](https://data.energystar.gov/resource/pbpq-swnu.json) | Median 1,082 kWh/yr | Tied with 28 peers at 846 kWh/yr (-236 kWh/yr, -21.8% vs median) |
| **Capacity** | 45.0 gal [[U.S. Environmental Protection Agency (ENERGY STAR)]](https://data.energystar.gov/resource/pbpq-swnu.json) | Standard gal rating | 18.8 kWh/gal (-1.4% vs 19.06 median) |
| **Cutout W × H × D** | 22.3" W × 61.8" H [[U.S. Environmental Protection Agency (ENERGY STAR)]](https://data.energystar.gov/resource/pbpq-swnu.json) | Released 2020 | Single model listing (1 SKU) |
| **Operating Cost (EIA)** | $153.63/yr [[U.S. Energy Information Administration (EIA)]](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) | 18.16 c/kWh US avg | Formula: 846 kWh × $0.1816 = $153.63/yr ($1,536.30 over 10 yrs) |
| **NAHB Service Life** | 10 years [[National Association of Home Builders (NAHB)]](https://www.nahb.org/) | 50% age gate: 5.0 yrs | Evaluate repair vs net replacement once age passes 6.5 yrs |
| **UEF** | 3.75 UEF | Electric | Certified efficiency metric |

## Which water heaters match 10E50-HP515 in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Water Heaters (Matched by Width & kWh Draw)

| Peer Model | Subtype | kWh/yr | Delta vs 10E50-HP515 | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| [**Friedrich PROH50 T2 FD400-15**](https://lamcoewp.com/models/water-heater/friedrich/proh50-t2-fd400-15/) | Hybrid/Electric Heat Pump | 846 | Same kWh | 45.0 gal | 22.3" W × 61.8" H | 1 |
| [**Friedrich PROH50 T2 FD400-30**](https://lamcoewp.com/models/water-heater/friedrich/proh50-t2-fd400-30/) | Hybrid/Electric Heat Pump | 846 | Same kWh | 45.0 gal | 22.3" W × 61.8" H | 1 |
| [**Friedrich PROH50 T2 FD400-SO**](https://lamcoewp.com/models/water-heater/friedrich/proh50-t2-fd400-so/) | Hybrid/Electric Heat Pump | 846 | Same kWh | 45.0 gal | 22.3" W × 61.8" H | 1 |
| [**Friedrich PROH50 T2 FD400-Z30**](https://lamcoewp.com/models/water-heater/friedrich/proh50-t2-fd400-z30/) | Hybrid/Electric Heat Pump | 846 | Same kWh | 45.0 gal | 22.3" W × 61.8" H | 1 |
| [**Rheem PROPH50 T2 RH375-15**](https://lamcoewp.com/models/water-heater/rheem/proph50-t2-rh375-15/) | Hybrid/Electric Heat Pump | 846 | Same kWh | 45.0 gal | 22.3" W × 61.8" H | 1 |

## Does 10E50-HP515 carry R-600a, duct, or installation boundaries?

10E50-HP515 (Hybrid/Electric Heat Pump, Electric, UEF 3.75) supplies residential hot water; heat-pump models need ~700 cu ft surrounding air volume.

Verify T&P relief valve discharge piping, thermal expansion tanks, and 240V/gas connections with a licensed plumber or electrician; check $1,750 DOE HEAR heat-pump credits.

- 10E50-HP515

## Should you repair 10E50-HP515 or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

Age (yrs)

Repair ($)

New Unit ($)

HEAR Credit

## FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

### What does Richmond 10E50-HP515 consume in kWh and dollars?

EPA data records 846 kWh/yr for Richmond 10E50-HP515, costing $153.63/yr ($1,536 over 10 years) at 18.16 cents/kWh across 1 consolidated SKU finishes.

### How far below the federal ceiling is Richmond 10E50-HP515?

It posts 10 CFR 430 certified and places #36 of 582 water heaters: -236 kWh/yr (-21.8%) relative to the 1082.0 kWh/yr median.

### At what age does Richmond 10E50-HP515 fail the 50% repair test?

Past 5.0 years of the 10-year NAHB benchmark, repair bids above half of net replacement minus $150 energy savings generally favor buying new.

### Which buyers should skip Richmond 10E50-HP515?

Skip 10E50-HP515 if cabinet openings cannot clear 22.3" W × 61.8" H, if 45.0 gal misses family sizing, or if commercial heavy-use durability is required.

### Are 10E50-HP515 mechanically the same model?

Yes; cosmetic finish trims (1 total SKUs) share identical 846 kWh/yr efficiency, 45.0 gal interior rating, and chassis assemblies.

### Which safety boundaries restrict Richmond 10E50-HP515 DIY work?

Always shut off the electrical breaker and water shutoff valve before opening 10E50-HP515 service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

### Which peer alternatives match Richmond 10E50-HP515?

Review the 5 closest water heaters listed above, sorted by 22.3" W × 61.8" H cutout, 45.0 gal capacity, and annual kWh similarity.

### What checks come before ordering Richmond 10E50-HP515 replacement parts?

Decode the serial manufacture year, verify active Richmond CPSC recalls, and test the repair quote in the 50% estimator above.

## Related guides

-  [ All Brand Serial Guides  ](https://lamcoewp.com/serial-decoder/)
-  [ Richmond Brand Profile  ](https://lamcoewp.com/brands/richmond/)
-  [ Compare Repair Quote vs HEAR Replacement Net Cost  ](https://lamcoewp.com/tools/repair-vs-replace/)
-  [ 1HVAC ACIQ-50G-HP- (855 kWh)  ](https://lamcoewp.com/models/water-heater/1hvac/aciq-50g-hp/)
-  [ Gridless AYHW50 (855 kWh)  ](https://lamcoewp.com/models/water-heater/gridless/ayhw50/)
-  [ Midea US3-RSJ-15/190RDVN3-L3 (855 kWh)  ](https://lamcoewp.com/models/water-heater/midea/us3-rsj-15-190rdvn3-l3/)

## Sources

1. [ENERGY STAR Certified Residential Water Heaters Dataset (pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
2. [Study of Life Expectancy of Home Components](https://www.nahb.org/) — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
3. [Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)