Spanning single SKU HPVX-50-DHPT 2**, State HPVX-50-DHPT 2 logs 1,550 kWh/yr ($281.48/yr at 18.16c/kWh) inside an 18-inch compact alcove built for 46.0 gal. Out of 1,169 certified U.S. water heaters, this Hybrid/Electric Heat Pump model achieves higher-draw: #564 / 582 — tied with 11 peers, uses less energy than 1.2% of 582 water heaters. Out-of-warranty owners weighing component quotes face $2,814.80 over a 10-year NAHB lifespan and ENERGY STAR certified compliance under 10 CFR 430.

- **Rated Energy** : 1,550 kWh/yr

- **EIA Annual Cost** : $281.48/yr

- **Category Rank** : #564 of 582

- **Capacity** : 46.0 gal

- **NAHB Lifespan** : 10 years

[All Brand Serial Guides](https://lamcoewp.com/serial-decoder/) [State Brand Profile](https://lamcoewp.com/brands/state/) [All Water Heaters (582)](https://lamcoewp.com/models/water-heater/)

Annual Energy Draw 1,550 kWh/yr Rank #564 / 582 (tied with 11 at 1,550 kWh/yr)

vs Water Heaters Median +468 kWh/yr (+43.3%) Median 1,082.0 kWh/yr

Federal Metric (UEF) 3.0 UEF 10 CFR 430 certified

Est. Operating Cost $281.48/yr $2,815 over 10 yr NAHB

## How does HPVX-50-DHPT 2 compare across all 582 water heaters?

State HPVX-50-DHPT 2 (1,550 kWh/yr) sits against the water heaters category median of 1,082.0 kWh/yr, +468 kWh/yr (+43.3%), and U.S. 10 CFR 430 baselines.

View quantile summary for Water Heaters — HPVX-50-DHPT 2

| Quantile / Marker | Annual kWh/yr |
|---|---|
| Most efficient model | 643 kWh/yr kWh |
| 25th percentile | 883 kWh/yr kWh |
| Category median | 1082 kWh/yr kWh |
| 75th percentile | 1289 kWh/yr kWh |
| Highest rated draw | 1741 kWh/yr kWh |

## Where does HPVX-50-DHPT 2 rank in operating-cost percentile?

Ranked #564 of 582 rated water heaters using EIA August 2026 national residential electricity rates (18.16 cents/kWh) over a 10-year NAHB median lifespan.

## What are the official specs and computed benchmarks for State HPVX-50-DHPT 2?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (10 years), and estimated operating electricity costs at 18.16 cents/kWh.

State HPVX-50-DHPT 2 — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)

| Specification / Metric | HPVX-50-DHPT 2 Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| **Rated Energy** | 1,550 kWh/yr [[U.S. Environmental Protection Agency (ENERGY STAR)]](https://data.energystar.gov/resource/pbpq-swnu.json) | Median 1,082 kWh/yr | Tied with 11 peers at 1,550 kWh/yr (+468 kWh/yr, +43.3% vs median) |
| **Capacity** | 46.0 gal [[U.S. Environmental Protection Agency (ENERGY STAR)]](https://data.energystar.gov/resource/pbpq-swnu.json) | Standard gal rating | 33.7 kWh/gal (+76.8% vs 19.06 median) |
| **Cutout W × H × D** | 15.0" W × 63.0" H [[U.S. Environmental Protection Agency (ENERGY STAR)]](https://data.energystar.gov/resource/pbpq-swnu.json) | Released 2023 | Single model listing (1 SKU) |
| **Operating Cost (EIA)** | $281.48/yr [[U.S. Energy Information Administration (EIA)]](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) | 18.16 c/kWh US avg | Formula: 1,550 kWh × $0.1816 = $281.48/yr ($2,814.80 over 10 yrs) |
| **NAHB Service Life** | 10 years [[National Association of Home Builders (NAHB)]](https://www.nahb.org/) | 50% age gate: 5.0 yrs | Evaluate repair vs net replacement once age passes 6.5 yrs |
| **UEF** | 3.0 UEF | Electric | Certified efficiency metric |

## Which water heaters match HPVX-50-DHPT 2 in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Water Heaters (Matched by Width & kWh Draw)

| Peer Model | Subtype | kWh/yr | Delta vs HPVX-50-DHPT 2 | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| [**A. O. Smith HPTV-50 2**](https://lamcoewp.com/models/water-heater/a-o-smith/hptv-50-2/) | Hybrid/Electric Heat Pump | 1,550 | Same kWh | 46.0 gal | 15.0" W × 63.0" H | 1 |
| [**A. O. Smith HPV10-50H01DV 2**](https://lamcoewp.com/models/water-heater/a-o-smith/hpv10-50h01dv-2/) | Hybrid/Electric Heat Pump | 1,550 | Same kWh | 46.0 gal | 15.0" W × 63.0" H | 1 |
| [**American HPV10250H009DV 2**](https://lamcoewp.com/models/water-heater/american/hpv10250h009dv-2/) | Hybrid/Electric Heat Pump | 1,550 | Same kWh | 46.0 gal | 15.0" W × 63.0" H | 1 |
| [**Lochinvar HPV050KD 2**](https://lamcoewp.com/models/water-heater/lochinvar/hpv050kd-2/) | Hybrid/Electric Heat Pump | 1,550 | Same kWh | 46.0 gal | 15.0" W × 63.0" H | 1 |
| [**RELIANCE WATER HEATERS 10-50-DHPTV 2**](https://lamcoewp.com/models/water-heater/reliance-water-heaters/10-50-dhptv-2/) | Hybrid/Electric Heat Pump | 1,550 | Same kWh | 46.0 gal | 15.0" W × 63.0" H | 1 |

## Does HPVX-50-DHPT 2 carry R-600a, duct, or installation boundaries?

HPVX-50-DHPT 2 (Hybrid/Electric Heat Pump, Electric, UEF 3.0) supplies residential hot water; heat-pump models need ~700 cu ft surrounding air volume.

Verify T&P relief valve discharge piping, thermal expansion tanks, and 240V/gas connections with a licensed plumber or electrician; check $1,750 DOE HEAR heat-pump credits.

- HPVX-50-DHPT 2**

## Should you repair HPVX-50-DHPT 2 or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

Age (yrs)

Repair ($)

New Unit ($)

HEAR Credit

## FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

### How much does running State HPVX-50-DHPT 2 cost each year?

At 18.16 cents/kWh (EIA August 2026), State HPVX-50-DHPT 2 draws 1550 kWh/yr, equating to $281.48/yr ($2,815 over 10 years) across all 1 finish trim, specifically HPVX-50-DHPT 2**.

### How efficient is State HPVX-50-DHPT 2 compared with federal ceilings?

Measured against 10 CFR 430 certified, State HPVX-50-DHPT 2 holds rank #564 out of 582 U.S. ENERGY STAR water heaters: +468 kWh/yr (+43.3%) vs median 1082.0 kWh/yr.

### Which minor parts are exceptions to replacing State HPVX-50-DHPT 2?

Routine wear items such as gaskets, lint filters, coin traps, or inlet mesh remain worthwhile past 5.0 years, whereas motor or board quotes above 50% net replacement favor replacement.

### When is State HPVX-50-DHPT 2 a poor match for a remodel?

Avoid State HPVX-50-DHPT 2 if 46.0 gal falls short of household demand, if hookups conflict with 15.0" W × 63.0" H, or if local electricity tariffs justify the lowest-kWh quartile.

### Do all variants in the State HPVX-50-DHPT 2 line use identical energy?

Yes; every listed finish — including HPVX-50-DHPT 2** — shares the identical 1550 kWh/yr ENERGY STAR test rating and 46.0 gal volume.

### What safety codes restrict State HPVX-50-DHPT 2 disassembly?

Always shut off the electrical breaker and water shutoff valve before opening HPVX-50-DHPT 2 service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

### How should owners confirm cutout clearance for State HPVX-50-DHPT 2?

Verify width, height, and depth against 15.0" W × 63.0" H, leaving extra rear space for cords, hoses, or condenser airflow.

### Where is the serial tag located on State HPVX-50-DHPT 2?

Inspect the inner liner wall, door rim, or tub flange via the State serial guide to decode build month and year before buying replacement assemblies.

## Related guides

-  [ All Brand Serial Guides  ](https://lamcoewp.com/serial-decoder/)
-  [ State Brand Profile  ](https://lamcoewp.com/brands/state/)
-  [ Compare Repair Quote vs HEAR Replacement Net Cost  ](https://lamcoewp.com/tools/repair-vs-replace/)
-  [ RELIANCE WATER 10-80-DHPTV 2 (1,654 kWh)  ](https://lamcoewp.com/models/water-heater/reliance-water-heaters/10-80-dhptv-2/)
-  [ Bradford White RTGR150X1 Specs  ](https://lamcoewp.com/models/water-heater/bradford-white/rtgr150x1/)
-  [ JUNSKY, RT*199IB Specs  ](https://lamcoewp.com/models/water-heater/junsky-camplux-gasland-thermomat/rt-199ib/)

## Sources

1. [ENERGY STAR Certified Residential Water Heaters Dataset (pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
2. [Study of Life Expectancy of Home Components](https://www.nahb.org/) — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
3. [Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)