CEME CES525BL Ceiling Fan Specs
Verified EPA ENERGY STAR test logs for CEME CES525BL list Airflow Efficiency 150.8 CFM/W and 52.0 in span, giving this higher-draw Standard Fan with Light Kit unit clear cost separation at -59.1 CFM/W (-28.2%) relative to the 209.9 CFM/W median. Built into a standard residential footprint, the assembly covers single SKU CES525BL. Cumulative power cost runs rated service expectations across a 15-year NAHB lifespan while holding ENERGY STAR certified vs 10 CFR 430.
- Rated Energy
- Ceiling Fans
- EIA Annual Cost
- Not listed
- Category Rank
- #1,029 of 1,241
- Capacity
- 52.0 in span
- NAHB Lifespan
- 15 years
What are the official specs and computed benchmarks for CEME CES525BL?
Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.
| Specification / Metric | CES525BL Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| Capacity | 52.0 in span [U.S. Environmental Protection Agency (ENERGY STAR)] | Standard in span rating | Density unavailable |
| Listing & Release | Released 2022 | 1 SKU | Single model listing (1 SKU) |
| NAHB Service Life | 15 years [National Association of Home Builders (NAHB)] | 50% age gate: 7.5 yrs | Evaluate repair vs net replacement once age passes 9.8 yrs |
| Airflow Efficiency | 150.8 CFM/W | Standard Fan with Light Kit | Certified efficiency metric |
Which ceiling fans match CES525BL in cutout width and energy draw?
Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.
| Peer Model | Subtype | kWh/yr | Delta vs CES525BL | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| CARRO CES525BL | Standard Fan with Light Kit | Not listed | Not listed | 52.0 in span | Not listed | 1 |
| Generation Lighting 3TNSM52***D | Standard Fan Only | Not listed | Not listed | 52.0 in span | Not listed | 1 |
| Generation Lighting 3TNSM52XXX | Standard Fan Only | Not listed | Not listed | 52.0 in span | Not listed | 1 |
| Monte Carlo 3TNSM52***D | Standard Fan Only | Not listed | Not listed | 52.0 in span | Not listed | 1 |
| Monte Carlo 3TNSM52XXX | Standard Fan Only | Not listed | Not listed | 52.0 in span | Not listed | 1 |
Does CES525BL carry R-600a, duct, or installation boundaries?
CES525BL (Standard Fan with Light Kit, 150.8 CFM/W) mounts to a UL-listed fan-rated ceiling electrical box with >= 7 ft blade clearance above floor.
Shut off wall switch and circuit breaker before servicing canopy wiring or balancing downrod blades.
- CES525BL
Should you repair CES525BL or replace it under the 50% rule?
Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.
FAQ
Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.
How much does running CEME CES525BL cost each year?
At 18.16 cents/kWh (EIA August 2026), CEME CES525BL draws certified ENERGY STAR status, equating to scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) across all 1 finish trim, specifically CES525BL.
How efficient is CEME CES525BL compared with federal ceilings?
Measured against 10 CFR 430 certified, CEME CES525BL holds rank #1,029 out of 1,241 U.S. ENERGY STAR ceiling fans: -59.1 CFM/W (-28.2%) vs median 0.0 kWh/yr.
Which minor parts are exceptions to replacing CEME CES525BL?
Routine wear items such as gaskets, lint filters, coin traps, or inlet mesh remain worthwhile past 7.5 years, whereas motor or board quotes above 50% net replacement favor replacement.
When is CEME CES525BL a poor match for a remodel?
Avoid CEME CES525BL if 52.0 in span falls short of household demand, if hookups conflict with OEM cutout blueprint, or if local electricity tariffs justify the lowest-kWh quartile.
Do all variants in the CEME CES525BL line use identical energy?
Yes; every listed finish — including CES525BL — shares the identical certified ENERGY STAR status ENERGY STAR test rating and 52.0 in span volume.
What safety codes restrict CEME CES525BL disassembly?
Always shut off the electrical breaker and water shutoff valve before opening CES525BL service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.
How should owners confirm cutout clearance for CEME CES525BL?
Verify width, height, and depth against OEM cutout blueprint, leaving extra rear space for cords, hoses, or condenser airflow.
Where is the serial tag located on CEME CES525BL?
Inspect the inner liner wall, door rim, or tub flange via the CEME serial guide to decode build month and year before buying replacement assemblies.
Related guides
Sources
- ENERGY STAR Certified Ceiling Fans Dataset (2te3-nmxp) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
- Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)