Skip to main content
OEM Fault & Ohm Reference

OEM Error Codes, Blink Charts & Multimeter Tolerances

Diagnose out-of-warranty residential washers, dryers, dishwashers, refrigerators, ovens, garage door openers, and smart deadbolts across 414 documented OEM error codes and 15 major brands. Each code lists exact factory meanings, isolated multimeter continuity or Ohm tolerance ranges, typical replacement part cost bands, and 50% replacement age checkpoints. All figures come directly from EPA ENERGY STAR, EIA utility records, CPSC and NHTSA safety recalls, federal safety standards, Bureau of Labor Statistics wages, and public state licensing boards for U.S. out-of-warranty home repairs.

Documented Error Codes
414
Brands Covered
15
Thermal Fuse Spec
0-1.5 Ohms
Photo-Eye Height Max
6 inches (16 CFR 1211)
Technician touching digital multimeter probes to copper terminals on a residential appliance drain pump motor.
Technician touching digital multimeter probes to copper terminals on a residential appliance drain pump motor.

Which manufacturer error code directories are indexed?

Jump straight to any of the 15 major residential appliance, garage door opener, and smart deadbolt brands below for complete fault definitions and component repair cost bands.

How do your multimeter Ohm readings compare against OEM tolerances?

Disconnect AC power and discharge high-voltage capacitors first, then select a component to test drain pumps (10-25 Ohms), inlet valves, thermal fuses, or NTC sensors.

  • LG / Samsung Drain Pump (10 - 25 Ohms)
  • Water Inlet Solenoid (800 - 1,400 Ohms)
  • Dryer Thermal Fuse (0 - 1.5 Ohms)
  • Dryer Heating Element (8 - 14 Ohms)
  • Oven RTD Sensor @ 70 F (1,050 - 1,120 Ohms)
  • NTC Thermistor @ 77 F (9,000 - 11,000 Ohms)

Which appliance fault tiers are safe for DIY vs pro escalation?

CodeBench separates accessible filter and continuity checks from hazardous sealed-refrigerant lines, 240V relays, gas manifolds, and preloaded garage door torsion springs.

Low Hazard
Coin trap cleaning, inlet screens, sensor alignment, alkaline battery swaps.
Moderate Hazard
Unplugged thermistor / pump ohm tests, AquaStop sump pan checks.
Pro Required
240V oven relays, gas valves, R-600a sealed cooling, garage torsion springs.

Which verified OEM error and blink codes are indexed?

414 codes

Filter 414 documented error, blink, and keypad fault codes across major residential washer, dryer, dishwasher, opener, and lock platforms with multimeter specs.

Verified OEM fault and blink codes with multimeter Ohm test specifications and hazard classification
Brand & CodeSystemDefinitionOhm / Test SpecHazard
LG OE Washer Drain pump timeout: washer did not drain within 10 minutes 10 - 25 Ohms at drain pump motor terminals Low
LG IE Washer Water inlet timeout: drum did not reach fill level within 8 minutes 800 - 1,200 Ohms at water inlet solenoid coils Low
LG UE Washer Unbalanced drum load detected during spin ramp Hall sensor tach & balance check (no static coil Ohm spec) Low
LG dE Washer Door lock switch failed to latch within 15 seconds Door lock PTC coil ~60 - 120 Ohms; latch switch 0 Ohms closed Moderate
LG d80 Dryer 80% exhaust duct blockage detected by Flow Sense pressure/temp curve Thermistor ~10k Ohms at 77 deg F (25 C) Moderate
LG Er IF Refrigerator Ice fan (freezer ice maker blower) motor speed error or ice buildup 12V DC fan motor continuity check (no open winding) Moderate
Samsung 5E / SE Washer Drain error: water level sensor failed to drop within drain cycle window 12 - 20 Ohms across drain pump motor terminals Low
Samsung 4E / 4C Washer Water supply error: insufficient fill detected 800 - 1,300 Ohms per inlet valve solenoid Low
Samsung dC / dE Washer Door open or lock sensing failure during cycle start 0 Ohms continuity across closed door switch contacts Moderate
Samsung HC / HE Dryer Heater / overheating thermal cutoff error or shorted relay Heating element 8 - 12 Ohms; thermal fuse 0 Ohms continuity Moderate
Samsung LC / LE Dishwasher Leak sensor triggered in bottom sump drip pan Float/leak sensor switch continuity open when dry Moderate
Whirlpool F9 E1 Washer Long drain time exceeded (6+ minutes without pressure drop) 10 - 20 Ohms on drain pump winding Low
Whirlpool F5 E2 Washer Door lock fault: latch solenoid failed to lock or sense closed Lock solenoid 60 - 110 Ohms; switch 0 Ohms locked Moderate
Whirlpool F1 E0 Oven / Range EEPROM / main relay control board internal fault Oven temp sensor ~1,080 Ohms at 70 deg F (separate verify) Pro Required
GE C1 / H2O Dishwasher Water supply fault or turbidity/float pressure switch timeout Inlet valve coil ~900 - 1,400 Ohms Low
GE F2 Oven / Range Oven cavity over-temperature detected (>615 deg F unlocked / >930 deg F clean) RTD sensor ~1,080 - 1,100 Ohms at 70 deg F Pro Required
Frigidaire i20 Dishwasher Drain timeout fault (pressure sensor still detects standing water) Drain pump ~15 - 25 Ohms; pressure sensor air trap clean Low
Bosch E15 Dishwasher AquaStop basepan float switch triggered by internal water leak Base float microswitch open circuit when dry Moderate
Bosch E24 Dishwasher Drain hose blocked, kinked, or drain pump cover unlatched 3-phase drain pump balanced windings ~75 - 105 Ohms per pair Low
Speed Queen Er dL Washer Door lock timeout / latch sensing switch open Door lock solenoid & switch continuity test at J-plug Moderate
LiftMaster / Chamberlain 1 Up / 1 Down Garage Door Opener Safety reversing sensors wire open, disconnected, or misaligned Low-voltage 2-wire DC loop (~6V DC pulse) Low
LiftMaster / Chamberlain 4 Up / 1 Down Garage Door Opener Downward travel excess force sensed (door binds or spring broken) RPM / travel module sensor pulse check Pro Required
Genie Red Blink (Safe-T-Beam) Garage Door Opener Safe-T-Beam photo-eye misaligned, obstructed, or sunlight interference Low-voltage Safe-T-Beam bus Low
Schlage 2 Red Flashes (BE469/BE479) Smart Deadbolt Deadbolt throw obstructed or low battery voltage under motor load 4x AA alkaline >= 5.6V resting Low
Kwikset 10 Red Flashes SmartCode Deadbolt Low battery or door handing process incomplete 4x AA alkaline >= 5.6V resting Low
Whirlpool F0 E2 Washer Excessive suds detected during wash or spin phase Pressure hose & drain pump 10 - 20 Ohms Low
Whirlpool F0 E4 Washer High water temperature during spin cycle (>105 deg F) Thermistor ~10k Ohms at 77 deg F Low
Whirlpool F0 E5 Washer Off-balance load sensed during high-speed spin ramp Suspension rod & tachometer speed check Low
Whirlpool F1 E1 Washer Main control board (ACU) relay or internal memory fault 120V AC supply verify at ACU J1 connector Pro Required
Whirlpool F1 E2 Washer Motor control unit (MCU) voltage or thermal fault Stator windings ~5 - 15 Ohms per phase pair Pro Required
Whirlpool F2 E1 Washer Stuck keypad or capacitive touch button held >15 seconds UI ribbon cable continuity check Moderate
Whirlpool F3 E1 Washer Water level pressure sensor out of calibration range Pressure switch frequency / air trap clear Moderate
Whirlpool F3 E2 Washer Inlet water temperature thermistor open or shorted NTC thermistor ~10k - 50k Ohms (temp dependent) Moderate
Whirlpool F5 E1 Washer Lid/door switch open while attempting cycle start 0 Ohms continuity across closed lid switch Low
Whirlpool F5 E3 Washer Door lock failed to unlock after cycle completion Lock solenoid 60 - 110 Ohms; PTC cool-down Moderate
Whirlpool F6 E1 Washer Communication error between UI panel and ACU board 5V DC / 12V DC harness continuity check Pro Required
Whirlpool F6 E2 Washer Communication drop between UI and Motor Control Unit Serial bus harness continuity (0 - 1 Ohm) Pro Required
Whirlpool F6 E3 Washer ACU to MCU communication timeout Harness continuity & 120V feed to MCU Pro Required
Whirlpool F7 E1 Washer Basket speed tachometer fault (drum cannot track RPM) Optical speed sensor / shift actuator ~2k Ohms Moderate
Whirlpool F7 E5 Washer Shift actuator failed to engage agitate or spin spline Shift actuator motor ~2,000 - 3,500 Ohms Moderate
Whirlpool F7 E6 Washer Drive motor open winding or relay circuit fault Motor start/run windings ~3 - 10 Ohms Moderate
Whirlpool F7 E7 Washer Motor unable to reach target spin RPM Drive belt tension & tach pulse check Moderate
Whirlpool F8 E1 Washer No water fill or slow fill timeout (>8 minutes) Water inlet solenoids 800 - 1,400 Ohms Low
Whirlpool F8 E3 Washer Overflow / high water level sensed above safe threshold Inlet valve seat seal & air tube check Moderate
Whirlpool F9 E2 Washer Drain pump motor thermal overload or electrical open Drain pump coil 10 - 20 Ohms Low
Whirlpool Sd / Sud Washer Suds lock detected reducing spin extraction efficiency No fault coil (detergent overuse lock) Low
Whirlpool F1 Dryer Primary electronic control board relay failure Relay board 120V/240V supply check Pro Required
Whirlpool F2 Dryer Stuck keypad button on dryer user interface Keypad ribbon matrix continuity check Moderate
Whirlpool F3 E1 Dryer Outlet exhaust thermistor open circuit Thermistor ~10k Ohms at 77 deg F (25 C) Moderate
Whirlpool F3 E2 Dryer Outlet exhaust thermistor shorted (excess temp read) Thermistor ~10k Ohms at 77 deg F (not <1k) Moderate
Whirlpool F4 E3 Dryer Restricted airflow / thermal cutoff tripped Thermal fuse 0 - 1.5 Ohms; heater 8 - 14 Ohms Moderate
Whirlpool PF Dryer Power failure interrupted active drying cycle 240V L1-L2 split-phase breaker check Low
Whirlpool AF Dryer Airflow restriction warning (>75% duct blockage) Rigid duct <= 35 ft (-5 ft per 90-deg elbow) Low
Whirlpool F1 E1-DW Dishwasher Dishwasher main control board relay fault Main board 120V AC feed check Pro Required
Whirlpool F3 E1-DW Dishwasher OWI turbidity / water temperature sensor fault Thermistor ~45k - 55k Ohms at 77 deg F Moderate
Whirlpool F4 E3-DW Dishwasher Wash circulation motor not running or low current draw Wash motor winding ~5 - 15 Ohms Moderate
Whirlpool F6 E1-DW Dishwasher Control unable to communicate with UI console UI ribbon continuity & 5V DC feed Pro Required
Whirlpool F7 E1-DW Dishwasher Heating element circuit fault (water failed to heat) Heating element 10 - 30 Ohms; hi-limit 0 Ohms Moderate
Whirlpool F8 E4 Dishwasher Float switch / basepan overfill leak trip Float microswitch 0 Ohms closed / OL open Moderate
Whirlpool F9 E1-DW Dishwasher Dishwasher drain timeout or blocked disposal port Drain pump 15 - 30 Ohms Low
Whirlpool F9 E2-DW Dishwasher Drain pump electrical open or locked rotor Drain pump coil 15 - 30 Ohms Moderate
Whirlpool F1 E1-OV Oven / Range Range safety relay or oven control fault RTD probe ~1,080 Ohms at 70 deg F Pro Required
Whirlpool F2 E0 Oven / Range Keypad cable disconnected or shorted button Keypad tail continuity test Moderate
Whirlpool F2 E1-OV Oven / Range Cancel key or keypad matrix stuck >60 seconds Keypad matrix open when unpressed Moderate
Whirlpool F3 E0 Oven / Range Oven temperature sensor open or shorted RTD sensor 1,050 - 1,120 Ohms at 70 deg F Moderate
Whirlpool F3 E1-OV Oven / Range Oven cavity temperature sensor out of range RTD sensor ~1,080 Ohms at 70 deg F Moderate
Whirlpool F5 E0 Oven / Range Self-clean door latch switch open/closed conflict Latch microswitch 0 Ohms closed Moderate
Whirlpool F6 E0 Oven / Range Lost communication between UI and appliance manager Harness continuity & 12V DC supply Pro Required
Whirlpool F8 E0 Oven / Range Cooling fan speed too low during bake or clean Cooling blower coil & Hall tach check Pro Required
Whirlpool PO Refrigerator Power outage alert after AC supply interruption 120V AC outlet voltage verify Low
Maytag F0 E1 Washer Load detected in drum during clean-washer cycle No sensor coil (basket must be empty) Low
Maytag F5 E1 Washer Lid/door switch fails to register closed position 0 Ohms closed across lid switch contacts Low
Maytag F5 E2 Washer Door lock solenoid timeout on Maxima/Bravos Lock coil 60 - 110 Ohms Moderate
Maytag F7 E1 Washer Basket speed sensor / tach fault Tachometer & shift actuator ~2k Ohms Moderate
Maytag F8 E1 Washer Long fill timeout or cold/hot supply blocked Water inlet coils 800 - 1,400 Ohms Low
Maytag F9 E1 Washer Drain timeout exceeding 6 minutes Drain pump motor 10 - 20 Ohms Low
Maytag oL Washer Overloaded basket / motor current limit tripped Drive motor windings ~3 - 10 Ohms Low
Maytag uL Washer Unbalanced load during spin extraction Suspension rod & leveling check Low
Maytag dL Washer Door lock failed to engage within 3 tries Lock solenoid 60 - 110 Ohms Moderate
Maytag nd Washer No drain: tub pressure remained high after drain phase Drain pump 10 - 20 Ohms Low
Maytag nF Washer No fill: insufficient water entered within 8 minutes Inlet valve solenoids 800 - 1,400 Ohms Low
Maytag LO Washer Door failed to unlock after cycle stop Door lock PTC & solenoid check Moderate
Maytag Sd Washer Excessive suds preventing drain/spin transition No part fault (excess detergent) Low
Maytag PF Washer Power failure mid-cycle 120V AC GFCI / breaker verify Low
Maytag AF Dryer Restricted airflow detected on Bravos/Maxima dryer IRC M1502 <= 35 ft rigid 4-in duct Low
Maytag F1 Dryer Dryer control board heater relay fault Main board relay test Pro Required
Maytag F3 E1 Dryer Exhaust thermistor open circuit Thermistor ~10k Ohms at 77 deg F Moderate
Maytag F4 E3 Dryer Dryer thermal cutoff / restricted vent overheat Thermal fuse 0 - 1.5 Ohms Moderate
Maytag F8 E4 Dishwasher Overfill float / basepan water sensor tripped Float switch 0 Ohms closed Moderate
Maytag F9 E1 Dishwasher Long drain fault in dishwasher sump Drain pump 15 - 30 Ohms Low
Maytag F2 Oven / Range Oven cavity over-temperature fault RTD probe ~1,080 Ohms at 70 deg F Pro Required
Maytag F3 E0 Oven / Range Oven RTD sensor open or shorted RTD probe 1,050 - 1,120 Ohms at 70 deg F Moderate
KitchenAid 6-4 Dishwasher Float switch open / overfill water detected Float switch 0 Ohms closed when resting Moderate
KitchenAid 7-1 Dishwasher Heating element failed to raise wash water temperature Heater coil 10 - 30 Ohms; hi-limit 0 Ohms Moderate
KitchenAid 8-1 Dishwasher Slow drain / sump standing water at end of cycle Drain pump 15 - 30 Ohms Low
KitchenAid 8-2 Dishwasher Drain pump electrical open or stalled rotor Drain pump winding 15 - 30 Ohms Moderate
KitchenAid 9-1 Dishwasher Diverter motor failed to index spray arm position Diverter motor ~1,200 - 2,000 Ohms Moderate
KitchenAid F1 E1 Dishwasher Dishwasher main control board internal relay fault 120V AC supply & board fuse check Pro Required
KitchenAid F3 E1 Dishwasher OWI turbidity / temperature sensor out of calibration Thermistor ~45k - 55k Ohms at 77 deg F Moderate
KitchenAid F6 E1 Dishwasher UI touchpad to control communication lost UI ribbon continuity check Pro Required
KitchenAid F7 E1 Dishwasher Heater circuit open or stuck open relay Heating element 10 - 30 Ohms Moderate
KitchenAid F8 E4 Dishwasher Overfill / drip tray leak switch triggered Drip tray switch continuity Moderate
KitchenAid F9 E1 Dishwasher Drain cycle exceeded maximum timeout Drain pump 15 - 30 Ohms Low
KitchenAid F1 E0 Oven / Range EOC control board EEPROM or keypad relay fault RTD check ~1,080 Ohms at 70 deg F Pro Required
KitchenAid F2 E1 Oven / Range Stuck key detected on touch panel >60s Keypad matrix open when idle Moderate
KitchenAid F3 E0 Oven / Range Oven RTD sensor open or shorted RTD probe 1,050 - 1,120 Ohms at 70 deg F Moderate
KitchenAid F3 E1 Oven / Range Oven cavity temperature sensor fault RTD probe ~1,080 Ohms at 70 deg F Moderate
KitchenAid F5 E0 Oven / Range Door lock switch state mismatch during self-clean Latch microswitch 0 Ohms closed Moderate
KitchenAid F6 E0 Oven / Range Serial communication failure between UI and power board Low-voltage comms harness continuity Pro Required
KitchenAid PO Refrigerator Power outage alert indicator 120V AC supply verify Low
GE E22 Washer Fill timeout: cold water valve slow or blocked Inlet valve solenoid ~900 - 1,300 Ohms Low
GE E23 Washer Fill timeout: hot water valve slow or blocked Inlet valve solenoid ~900 - 1,300 Ohms Low
GE E31 Washer Drain pump failed to evacuate tub within 6 minutes Drain pump winding 10 - 25 Ohms Low
GE E38 Washer Severe unbalanced load during spin cycle Suspension / balance ring check Low
GE E39 Washer Dispenser diverter motor fault Dispenser motor resistance check Moderate
GE E46 Washer Inverter / drive motor over-temperature cutoff Motor phase windings ~5 - 15 Ohms Pro Required
GE E60 Washer Door lock switch failed to latch Lock solenoid ~60 - 120 Ohms; switch 0 Ohms Moderate
GE E61 Washer Door failed to unlock after spin stop Door lock release solenoid check Moderate
GE E60-DR Dryer Exhaust thermistor temperature reading error Thermistor ~10k Ohms at 77 deg F Moderate
GE E61-DR Dryer Dryer inlet thermistor or thermostat out of range High-limit thermostat 0 Ohms closed Moderate
GE E64 Dryer Heater relay stuck or element grounded to cabinet Heating element 8 - 14 Ohms; OL to ground Pro Required
GE E65 Dryer Moisture sensor bars open or shorted Sensor bars open when dry (infinite Ohms) Low
GE tO Dryer Timed dry or vent restriction timeout IRC M1502 <= 35 ft rigid duct Low
GE F96 Dishwasher Dishwasher circulation motor or turbidity timeout Circulation motor ~10 - 25 Ohms Moderate
GE F97 Dishwasher Water heating failed to rise during wash cycle Heating element 10 - 30 Ohms Moderate
GE F98 Dishwasher Drain motor failed to empty sump Drain pump 12 - 25 Ohms Low
GE LOC Dishwasher Control Lock (Child Lock) enabled on touchpad No fault coil (button lock active) Low
GE dE Dishwasher Door latch switch open during cycle start Door latch switch 0 Ohms closed Moderate
GE FF Refrigerator Freezer evaporator fan speed or frost blockage alert 12V DC fan motor continuity check Moderate
GE HRS Refrigerator Run time exceeded without reaching target cooling temp Thermistor ~10k Ohms @ 77 F; R-600a rules Pro Required
GE CC Refrigerator Check Controls / cooling loss (>15 deg F rise) Thermistor & defrost heater 15 - 35 Ohms Moderate
GE CI Refrigerator Check Ice Maker sensor or stalled ejector arm Ice maker heater & thermistor check Low
GE PF Refrigerator Power failure alert on refrigerator display 120V AC receptacle verify Low
GE F0 Oven / Range Stuck Cancel/Off key or UI touch short Keypad membrane continuity check Moderate
GE F3 Oven / Range Oven cavity temperature sensor open circuit RTD probe 1,050 - 1,120 Ohms at 70 deg F Moderate
GE F4 Oven / Range Oven temperature sensor shorted (<800 Ohms) RTD probe ~1,080 Ohms at 70 deg F Moderate
GE F5 Oven / Range Watchdog / internal control microprocessor fault 120V/240V terminal supply verify Pro Required
GE F7 Oven / Range Function key stuck on keypad Membrane ribbon open check Moderate
GE F9 Oven / Range Oven door lock failed to latch during self-clean Lock motor ~1,500 - 2,500 Ohms Moderate
LG dE1 Washer Door switch open or failed to sense closed Latch switch 0 Ohms closed Moderate
LG dE2 Washer Door lock motor failed to lock after closing Lock PTC coil ~60 - 120 Ohms Moderate
LG LE Washer Locked motor error: drum rotor overloaded or Hall sensor open Stator ~5 - 15 Ohms/phase; Hall sensor ~10k Moderate
LG FE Washer Water overfill error: inlet valve failed to shut off Water inlet coils 800 - 1,200 Ohms Moderate
LG PE Washer Water level pressure switch out of range Pressure switch pin voltage / air hose clear Moderate
LG tE Washer Wash water thermistor open or shorted Thermistor ~48k Ohms at 68 deg F Moderate
LG CE Washer Over-current fault on Direct Drive motor inverter Stator windings ~5 - 15 Ohms balanced Pro Required
LG PF Washer Power failure interrupted active wash cycle 120V AC outlet verify Low
LG CL Washer Child Lock active (controls locked) No fault coil (button lock active) Low
LG Sud Washer Excessive suds detected in tub No fault coil Low
LG CD Washer Cool Down phase running (high-temp cycle end) Normal operation indicator Low
LG E6 Washer Clutch / hall sensor engagement fault on top-loader Clutch coil & Hall sensor check Moderate
LG d90 Dryer 90% exhaust duct blockage detected by Flow Sense Thermistor ~10k Ohms @ 77 F Moderate
LG d95 Dryer 95% severe exhaust airflow restriction (heater shuts off) Thermal cutoff 0 - 1.5 Ohms Moderate
LG tE1 Dryer Dryer outlet thermistor open or out of range Thermistor ~10k Ohms at 77 deg F Moderate
LG tE2 Dryer Dryer thermistor shorted (<500 Ohms) Thermistor ~10k Ohms at 77 deg F Moderate
LG tE3 Dryer Secondary / steam thermistor fault Thermistor ~10k Ohms at 77 deg F Moderate
LG nP Dryer No Power on L2 heater leg (240V supply fault) 240V L1-L2 across terminal block Pro Required
LG E1 Dryer Gas ignition or thermostat cutoff timeout Gas valve coils ~1,200 - 1,400 Ohms Pro Required
LG Er FF Refrigerator Freezer fan motor feedback error 12V DC fan motor continuity Moderate
LG Er rF Refrigerator Fresh food refrigerator fan motor error 12V DC fan motor continuity Moderate
LG Er CF Refrigerator Condenser fan motor error behind lower rear cover 12V DC condenser fan check Moderate
LG Er dH Refrigerator Defrost heater timeout (evaporator did not reach 45 F) Defrost heater 20 - 40 Ohms; fuse 0 Ohms Moderate
LG Er FS Refrigerator Freezer thermistor open or shorted Thermistor ~10k - 30k Ohms (temp dependent) Moderate
LG Er rS Refrigerator Fresh food compartment thermistor error Thermistor ~10k Ohms at 77 deg F Moderate
LG Er IS Refrigerator Ice maker sensor / ice fan assembly error Ice thermistor & motor check Moderate
LG Er gF Refrigerator Water flowmeter sensor failed to detect pulses Flowmeter Hall pulse check Moderate
LG Er CO Refrigerator Communication error between main PCB and display PCB Door hinge wire harness continuity Pro Required
LG OE Dishwasher Dishwasher drain timeout (>5 minutes) Drain pump 15 - 30 Ohms Low
LG IE Dishwasher Water inlet timeout in dishwasher Inlet valve solenoid 800 - 1,300 Ohms Low
LG AE Dishwasher Aqua-Stop basepan leak sensor triggered Float microswitch continuity Moderate
LG LE Dishwasher Wash motor locked rotor or inverter fault Direct Drive wash motor ~5 - 15 Ohms Moderate
LG HE Dishwasher Water heating element or relay fault Heater coil 10 - 25 Ohms Moderate
LG tE Dishwasher Wash water thermistor error Thermistor ~10k - 50k Ohms Moderate
LG FE Dishwasher Overfill detected in dishwasher tub Inlet valve seat & flowmeter check Moderate
LG nE Dishwasher Vario spray-arm diverter motor position error Diverter microswitch & motor check Moderate
LG F-1 Oven / Range Oven cavity temperature sensor open circuit RTD probe ~1,080 Ohms at 70 deg F Moderate
LG F-2 Oven / Range Oven RTD sensor shorted RTD probe ~1,080 Ohms at 70 deg F Moderate
LG F-3 Oven / Range Touchpad / control key shorted >60 seconds Keypad matrix continuity check Moderate
LG F-6 Oven / Range Oven cavity over-temperature fault RTD probe ~1,080 Ohms at 70 deg F Pro Required
LG F-9 Oven / Range Oven failed to heat within 5 minutes of bake start Bake element 15 - 35 Ohms (electric) Moderate
LG F-11 Oven / Range No temperature rise in upper/lower oven cavity Bake/Broil element 15 - 35 Ohms Moderate
Samsung 5C Washer Drain timeout (modern Samsung code replacing 5E) Drain pump 12 - 20 Ohms Low
Samsung 4C2 Washer Cold supply hose connected to hot water >122 deg F No part fault (hose swap) Low
Samsung dC1 Washer Door lock latch failed to engage/release Lock solenoid ~60 - 120 Ohms Moderate
Samsung UB / UE Washer Unbalanced drum load during spin ramp Suspension dampers & Hall sensor Low
Samsung UR Washer Unbalanced spin retry active Suspension dampers check Low
Samsung LC Washer Water leak detected in washer basepan Leak sensor switch continuity Moderate
Samsung 1E / 1C Washer Water level pressure sensor fault Pressure switch frequency check Moderate
Samsung 3E / 3C Washer Drive motor Hall / tach speed fault Stator ~5 - 15 Ohms/phase; Hall check Moderate
Samsung tE Washer Water temperature thermistor error Thermistor ~10k - 50k Ohms Moderate
Samsung Sud Washer Excessive foam/suds detected during cycle No part fault Low
Samsung tE Dryer Dryer thermistor open or shorted Thermistor ~10k Ohms at 77 deg F Moderate
Samsung tO Dryer Dryer time-out / airflow restriction warning IRC M1502 <= 35 ft rigid duct Low
Samsung dE / dC Dryer Dryer door switch open during cycle start Door switch 0 Ohms closed Low
Samsung 9E1 / 9C1 Dryer Abnormal power voltage (<100V or >260V) detected 240V L1-L2 at terminal block Pro Required
Samsung bE Dryer Stuck control button (>30s pressed) UI button membrane check Moderate
Samsung FC Dryer Invalid power line frequency sensed Main PCB & 60 Hz supply check Pro Required
Samsung CL Dryer Vent / lint check reminder or Child Lock No fault coil Low
Samsung 1E Refrigerator Freezer / ice maker sensor open or shorted Thermistor ~10k - 30k Ohms Moderate
Samsung 5E Refrigerator Fresh-food defrost sensor open or shorted Defrost thermistor ~5k - 15k Ohms Moderate
Samsung 8E Refrigerator Ice maker sensor / auger error Ice room thermistor check Moderate
Samsung 21E Refrigerator Freezer evaporator fan motor error 12V DC fan motor continuity Moderate
Samsung 22E Refrigerator Fresh-food evaporator fan motor error (twin cooling) 12V DC fan motor continuity Moderate
Samsung 23E Refrigerator Condenser fan motor error at lower rear bay 12V DC fan check Moderate
Samsung 24E Refrigerator Freezer defrost failure (excess frost accumulation) Defrost heater 20 - 45 Ohms; bimetal 0 Ohms Moderate
Samsung 25E Refrigerator Fresh-food evaporator defrost failure Defrost heater 25 - 50 Ohms; fuse 0 Ohms Moderate
Samsung 26E Refrigerator Water valve or ice maker fill feedback error Water inlet solenoid ~300 - 500 Ohms Moderate
Samsung 33E Refrigerator Ice room water fill pipe heater open Fill tube heater continuity check Moderate
Samsung 39E Refrigerator Ice maker motor / test switch fault Ice maker test switch check Moderate
Samsung 40E Refrigerator Ice room cooling fan motor error 12V DC ice fan check Moderate
Samsung 84C Refrigerator Inverter compressor locked rotor / overload Compressor windings balanced ~5 - 15 Ohms Pro Required
Samsung PC Er Refrigerator Door-hinge communication error (display to main PCB) Hinge harness continuity check Pro Required
Samsung 4C Dishwasher Water supply timeout in dishwasher Inlet solenoid 800 - 1,300 Ohms Low
Samsung 5C Dishwasher Drain timeout in dishwasher Drain pump 12 - 25 Ohms Low
Samsung OC / oE Dishwasher Overfill water level error Case brake / flowmeter & valve check Moderate
Samsung HE Dishwasher Water heating element / relay error Heater element 10 - 25 Ohms Moderate
Samsung tE Dishwasher Sump temperature thermistor fault Thermistor ~10k - 50k Ohms Moderate
Samsung AP Dishwasher Wi-Fi Access Point pairing mode active No fault coil Low
Samsung SE Oven / Range Stuck key or shorted membrane touchpad Keypad ribbon continuity Moderate
Samsung C-20 Oven / Range Oven temperature sensor open or shorted RTD probe ~1,080 Ohms at 70 deg F Moderate
Samsung C-21 Oven / Range Oven cavity over-temperature fault RTD probe ~1,080 Ohms at 70 deg F Pro Required
Samsung C-30 Oven / Range Main PCB ambient temperature sensor fault PCB cooling & ambient thermistor check Pro Required
Samsung C-d0 Oven / Range Keypad button shorted >30 seconds Keypad matrix open check Moderate
Samsung C-d1 Oven / Range Self-clean door lock switch error Door lock motor & switch continuity Moderate
Samsung C-F0 Oven / Range Communication error between display and main PCB Serial harness continuity check Pro Required
Frigidaire E11 Washer Fill time exceeded (insufficient water intake) Inlet solenoids 800 - 1,300 Ohms Low
Frigidaire E13 Washer Water leak detected in basepan or pressure drift Pressure sensor & hose seal check Moderate
Frigidaire E21 Washer Water not pumping out fast enough (drain timeout) Drain pump 12 - 22 Ohms Low
Frigidaire E23 Washer Drain pump triac failure on main control board Drain pump 12 - 22 Ohms (verify first) Pro Required
Frigidaire E24 Washer Drain pump triac sensing circuit fault Drain pump & harness continuity Pro Required
Frigidaire E31 Washer Electronic pressure switch frequency fault Pressure switch air tube clear Moderate
Frigidaire E41 Washer Door open or door lock switch not sensing closed Door lock switch 0 Ohms closed Moderate
Frigidaire E42 Washer Door lock device failure (wax motor/solenoid) Lock PTC/solenoid ~60 - 120 Ohms Moderate
Frigidaire E43 Washer Main control board door-lock triac fault Door lock coil verify before board swap Pro Required
Frigidaire E56 Washer High motor current / bound drum bearing or spider Drive motor windings ~5 - 15 Ohms Pro Required
Frigidaire E57 Washer Inverter board over-current >15 Amps Motor phase windings balanced ~5 - 15 Ohms Pro Required
Frigidaire E59 Washer No tachometer signal from motor for 3 seconds Tach coil ~115 - 170 Ohms Moderate
Frigidaire E5A Washer High temperature on motor speed control heatsink Inverter heatsink cooling check Pro Required
Frigidaire E61 Washer Wash water heater heating too slowly Heater element 20 - 35 Ohms Moderate
Frigidaire E91 Washer Communication error between UI and main control UI-to-main comms harness continuity Pro Required
Frigidaire EF0 Washer Excess suds or blocked drain filter screen Drain pump 12 - 22 Ohms Low
Frigidaire E4A Dryer Dryer heating cycle time exceeded (>150 minutes) IRC M1502 <= 35 ft rigid 4-in duct Low
Frigidaire E64 Dryer Open heating element circuit Heating coil 8 - 14 Ohms; high-limit 0 Ohms Moderate
Frigidaire E68 Dryer Stuck control button (>30s) Keypad continuity check Moderate
Frigidaire EF1 Dryer Restricted exhaust vent airflow alert 4-in rigid duct <= 35 ft Low
Frigidaire i10 Dishwasher Low water fill detected in dishwasher Inlet valve solenoid ~900 - 1,400 Ohms Low
Frigidaire i30 Dishwasher Leak protection float triggered in bottom pan Basepan float switch 0 Ohms tripped Moderate
Frigidaire i40 Dishwasher Turbidity / pressure sensor calibration error Pressure trap clean check Moderate
Frigidaire i50 Dishwasher Drain or wash motor triac control fault Pump coils ~15 - 25 Ohms Pro Required
Frigidaire i60 Dishwasher Water heating timeout or open heater circuit Heating element 10 - 30 Ohms Moderate
Frigidaire uo Dishwasher Active vent open or jammed during dry cycle Vent wax motor / switch continuity Moderate
Frigidaire SY EF Refrigerator Evaporator fan circuit fault 12V DC fan motor check Moderate
Frigidaire SY CF Refrigerator Communication error between UI display and main board Door harness continuity check Pro Required
Frigidaire SY CE Refrigerator Control communication timeout Harness continuity check Pro Required
Frigidaire OP Refrigerator Open thermistor circuit (freezer or fresh food) Thermistor ~10k Ohms at 77 deg F Moderate
Frigidaire SH Refrigerator Shorted thermistor circuit Thermistor ~10k Ohms at 77 deg F (not <500) Moderate
Frigidaire H1 Refrigerator High-temperature alarm (>23 F freezer / >46 F fridge) Door gasket & condenser fan check Low
Frigidaire F10 Oven / Range Runaway oven temperature (>650 deg F) RTD probe ~1,080 Ohms at 70 deg F Pro Required
Frigidaire F11 Oven / Range Shorted keypad or touchpad membrane Touchpad ribbon open check Moderate
Frigidaire F13 Oven / Range EEPROM / internal EOC control board fault 120V/240V supply verify Pro Required
Frigidaire F30 Oven / Range Open oven temperature sensor probe RTD probe 1,050 - 1,120 Ohms at 70 deg F Moderate
Frigidaire F31 Oven / Range Shorted oven temperature sensor probe RTD probe ~1,080 Ohms at 70 deg F Moderate
Frigidaire F90 Oven / Range Maximum door unlock time exceeded on self-clean Door lock motor ~1,500 - 2,500 Ohms Moderate
Bosch E01 Dishwasher Power module relay fault (heating relay welded/open) Main board relay & heater circuit Pro Required
Bosch E02 Dishwasher Heating relay failure on main power module Heat pump / heater ~10 - 25 Ohms Pro Required
Bosch E04 Dishwasher Heater relay / diverter valve circuit fault Heat pump & NTC check Pro Required
Bosch E06 Dishwasher Door latch / Hall sensor state error Door sensor switch continuity Moderate
Bosch E09 Dishwasher Heating circuit open in circulation heat pump Heat pump heater coil ~10 - 20 Ohms Pro Required
Bosch E11 Dishwasher Sump NTC temperature sensor open or shorted NTC thermistor ~10k Ohms at 77 deg F Moderate
Bosch E14 Dishwasher Water inlet reed flowmeter not registering pulses Flowmeter reed switch pulse check Moderate
Bosch E18 Dishwasher Water supply fill level too low (inlet timeout) Inlet AquaStop solenoid ~1,800 - 2,500 Ohms Low
Bosch E19 Dishwasher Detergent dispenser / water-exchanger drain valve fault Valve solenoid ~1,500 - 2,500 Ohms Moderate
Bosch E22 Dishwasher Residual water left in sump / clogged micro-filter 3-phase drain pump ~75 - 105 Ohms/pair Low
Bosch E25 Dishwasher Drain pump impeller blocked or pump cover unlatched 3-phase pump ~75 - 105 Ohms/pair Low
Bosch E27 Dishwasher Low AC line voltage (<95V AC) detected 120V AC supply voltage verify Low
Bosch E16 Washer Door open when wash cycle started Door lock switch 0 Ohms closed Low
Bosch E17 Washer Water inlet timeout (>6 minutes) Inlet solenoid 800 - 1,300 Ohms Low
Bosch E18 Washer Drain pump timeout (>6 minutes) Drain pump 10 - 25 Ohms Low
Bosch E23 Washer AquaStop basepan float leak triggered Base float microswitch continuity Moderate
Bosch E29 Washer No water pressure / closed tap detected Inlet valve solenoid check Low
Bosch E36 Washer Door lock failed to lock/unlock cleanly Lock solenoid ~60 - 120 Ohms Moderate
Bosch E01 Dryer Fluff / lint filter & condenser airflow alert (heat pump) No ohm fault (condenser clean needed) Low
Bosch E06 Dryer Dryer door switch sensing error Door switch 0 Ohms closed Low
Bosch E10 Dryer Heat pump / heater NTC temperature sensor error Thermistor ~10k Ohms at 77 deg F Moderate
Bosch E50 Dryer Drive motor overload or control inverter fault Motor windings ~5 - 15 Ohms Pro Required
Speed Queen Er dO Washer Door open when Start pressed Door switch 0 Ohms closed Low
Speed Queen Er dU Washer Door unlock timeout at end of cycle Lock solenoid & wax motor continuity Moderate
Speed Queen Er FL Washer Fill time limit exceeded (10+ minutes) Inlet solenoids 800 - 1,300 Ohms Low
Speed Queen Er nF Washer No fill water flow sensed Inlet solenoids & pressure hose check Low
Speed Queen Er dr Washer Drain timeout (water still detected in outer tub) Drain pump 10 - 22 Ohms Low
Speed Queen Er ub Washer Out-of-balance condition aborted high-speed spin Out-of-balance switch 0 Ohms closed Low
Speed Queen Er SL Washer Suds lock or slow drain during spin ramp Drain pump 10 - 22 Ohms Low
Speed Queen PF Washer Power failure interrupted wash cycle 120V AC supply verify Low
Speed Queen Er Ht Dryer Heater / over-temperature limit fault High-limit thermostat 0 Ohms closed Moderate
Speed Queen Er do Dryer Dryer door open during start Door switch 0 Ohms closed Low
Speed Queen Er op Dryer Open outlet thermistor circuit Thermistor ~10k Ohms at 77 deg F Moderate
Speed Queen Er SH Dryer Shorted outlet thermistor circuit Thermistor ~10k Ohms at 77 deg F Moderate
Amana F1 E1 Washer Main control board internal fault 120V AC supply check Pro Required
Amana F5 E2 Washer Lid/door lock failed to engage Lock coil 60 - 110 Ohms Moderate
Amana F7 E1 Washer Basket speed tachometer fault Shift actuator ~2k - 3.5k Ohms Moderate
Amana F8 E1 Washer No fill / slow water fill timeout Inlet valve coils 800 - 1,400 Ohms Low
Amana F9 E1 Washer Long drain time (>6 minutes) Drain pump 10 - 20 Ohms Low
Amana PF Dryer Power outage interrupted drying 240V breaker verify Low
Amana F2 Oven / Range Oven cavity over-temperature fault RTD sensor ~1,080 Ohms at 70 deg F Pro Required
Amana F3 Oven / Range Oven RTD sensor open or shorted RTD probe 1,050 - 1,120 Ohms at 70 deg F Moderate
Kenmore F20 Washer (110. Whirlpool OEM) No water detected entering tub or flowmeter fault Inlet coils 800 - 1,400 Ohms Low
Kenmore F21 Washer (110. Whirlpool OEM) Long drain timeout (>8 minutes) Drain pump 10 - 20 Ohms Low
Kenmore F22 Washer (110. Whirlpool OEM) Door lock sensing failure Lock solenoid 60 - 110 Ohms Moderate
Kenmore F24 Washer (110. Whirlpool OEM) Water temperature sensor out of range Thermistor ~10k - 50k Ohms Moderate
Kenmore F28 Washer (110. Whirlpool OEM) Communication error between CCU and MCU Comms harness continuity check Pro Required
Kenmore F30 Washer (110. Whirlpool OEM) Dispenser motor cannot locate cam position Dispenser motor ~1,200 - 2,000 Ohms Moderate
Kenmore OE Washer (796. LG OEM) Drain timeout on LG-built Kenmore Elite washer Drain pump 10 - 25 Ohms Low
Kenmore UE Washer (796. LG OEM) Unbalanced drum load on LG-built Kenmore Elite Hall tach & shock dampers check Low
Kenmore LE Washer (796. LG OEM) Locked motor / Hall sensor on 796. Direct Drive Stator ~5 - 15 Ohms/phase Moderate
Kenmore Er IF Refrigerator (795. LG OEM) Ice fan speed fault on LG-built Kenmore 795. 12V DC ice fan continuity Moderate
Kenmore i20 Dishwasher (587. Frigidaire OEM) Drain timeout on Frigidaire-built Kenmore 587. Drain pump 15 - 25 Ohms Low
Kenmore E11 Washer (417. Frigidaire OEM) Fill timeout on Frigidaire-built Kenmore 417. Inlet coils 800 - 1,300 Ohms Low
Kenmore F10 Oven / Range (790. Frigidaire OEM) Runaway oven temperature on Frigidaire-built Kenmore 790. RTD probe ~1,080 Ohms at 70 deg F Pro Required
Kenmore F31 Oven / Range (790. Frigidaire OEM) Shorted oven RTD sensor on Kenmore 790. RTD probe ~1,080 Ohms at 70 deg F Moderate
LiftMaster / Chamberlain 1 Up / 2 Down Garage Door Opener Safety reversing sensors wire shorted or reversed polarity Low-voltage 2-wire DC loop (~6V DC) Low
LiftMaster / Chamberlain 1 Up / 3 Down Garage Door Opener Door control / wall button wire shorted Wall console 2-wire DC loop Low
LiftMaster / Chamberlain 1 Up / 4 Down Garage Door Opener Safety reversing sensors slightly misaligned (momentary beam break) 6V DC modulated sensor pulse Low
LiftMaster / Chamberlain 1 Up / 5 Down Garage Door Opener Motor overheated or RPM sensor failed to register motion RPM optical sensor 5V pulse check Moderate
LiftMaster / Chamberlain 2 Up / 1 Down Garage Door Opener Logic board memory or EEPROM fault Logic board 120V AC / DC supply Pro Required
LiftMaster / Chamberlain 2 Up / 2 Down Garage Door Opener Logic board internal relay or safety circuit fault Logic board diagnostic check Pro Required
LiftMaster / Chamberlain 2 Up / 3 Down Garage Door Opener Logic board motor relay stuck or travel limit lost Travel module & logic board Pro Required
LiftMaster / Chamberlain 3 Up / 2 Down Garage Door Opener Unable to set travel or position limits Travel module encoder pulse Moderate
LiftMaster / Chamberlain 3 Up / 3 Down Garage Door Opener Battery backup charging circuit fault (CA SB-969 units) 12V SLA battery >= 12.4V resting Low
LiftMaster / Chamberlain 4 Up / 2 Down Garage Door Opener Upward travel excessive force sensed (door heavy / broken spring) Door balance check (door CLOSED) Pro Required
LiftMaster / Chamberlain 4 Up / 3 Down Garage Door Opener Upward travel stopped by physical obstruction or binding track Track roller & lock latch check Low
LiftMaster / Chamberlain 4 Up / 5 Down Garage Door Opener Opener moved 6-8 inches and stopped (RPM or travel failure) Travel module / capacitor check Moderate
LiftMaster / Chamberlain 4 Up / 6 Down Garage Door Opener Safety sensor interrupted during downward travel (door reversed) Photo-eyes <= 6 in off floor (16 CFR 1211) Low
LiftMaster / Chamberlain 10 Work Light Flashes Garage Door Opener 16 CFR 1211 safety sensor tripped while closing Photo-eye alignment & 2s reversal Low
Genie 1 Red Blink Garage Door Opener Safe-T-Beam sensor obstruction or wire open Safe-T-Beam low-voltage bus Low
Genie 2 Red Blinks Garage Door Opener Safe-T-Beam wire shorted or reversed Safe-T-Beam 2-wire continuity Low
Genie 3 Red Blinks Garage Door Opener Safe-T-Beam hardware fault or sunlight overload Safe-T-Beam voltage verify Low
Genie 4 Red Blinks Garage Door Opener Safe-T-Beam source emitter failure Safe-T-Beam bus Low
Genie 5 Red Blinks Garage Door Opener Travel limit switch or opto-wheel fault Opto-interrupter / limit check Moderate
Genie 6 Red Blinks Garage Door Opener Excess motor force / broken door spring detected Manual balance check (door CLOSED) Pro Required
Genie Orange Battery LED Garage Door Opener Genie Integrated Battery Backup low or disconnected 24V / 12V battery voltage test Low
Schlage 3 Red Flashes Smart Deadbolt Incorrect User Code or Programming Code entered 4x AA alkaline >= 5.6V resting Low
Schlage 4 Red Flashes Smart Deadbolt Keypad temporarily locked out after 4 wrong codes No fault coil Low
Kwikset 3 Red Blinks SmartCode Deadbolt Low battery warning (bolt speed slowing) 4x AA alkaline >= 5.6V resting Low
Kwikset Alternating Red/Green SmartCode Deadbolt SmartCode programming error or failed user code delete 4x AA alkaline >= 5.6V Low
Whirlpool F0 E3 Washer Overload condition detected during wash or spin sensing Drive motor windings ~3 - 10 Ohms Low
Whirlpool F0 E7 Washer Load detected in drum during clean-washer cycle No sensor coil Low
Whirlpool F1 E3 Washer ACU mismatch or EEPROM configuration error 120V AC supply verify Pro Required
Whirlpool F2 E3 Washer UI and ACU software / button mismatch fault UI ribbon continuity check Pro Required
Whirlpool F3 E3 Washer Wash water temperature thermistor out of calibration NTC thermistor ~10k - 50k Ohms Moderate
Whirlpool F4 E1 Washer Wash water heater relay failure on ACU Heater element 15 - 30 Ohms Pro Required
Whirlpool F4 E2 Washer Water heating timeout (temp failed to rise) Heater element 15 - 30 Ohms Moderate
Whirlpool F8 E2 Washer Dispenser motor failed to reach target cam position Dispenser actuator motor check Moderate
Whirlpool F8 E5 Washer Hot and cold supply hoses reversed Inlet thermistor temp check Low
Whirlpool F9 E3 Washer Drain pump circuit open or control relay dropped Drain pump 10 - 20 Ohms Moderate
Whirlpool rL Washer Drum rotation / item detected during Clean Washer No part fault Low
GE E11 Washer Water fill timeout (slow or no water entry) Inlet solenoids ~900 - 1,300 Ohms Low
GE E21 Washer Main drain timeout (>6 minutes) Drain pump 10 - 25 Ohms Low
GE E26 Washer Water level pressure sensor out of range Pressure sensor hose clear Moderate
GE E33 Washer Drive motor thermal overload or locked rotor Motor phase windings ~5 - 15 Ohms Moderate
GE E45 Washer Inverter communication or tachometer signal fault Tach / Hall sensor check Pro Required
GE E1 Dryer Thermistor temperature sensor open circuit Thermistor ~10k Ohms at 77 deg F Moderate
GE E2 Dryer Thermistor temperature sensor shorted Thermistor ~10k Ohms at 77 deg F Moderate
GE E3 Dryer High-limit thermostat or exhaust over-temp trip High-limit thermostat 0 Ohms closed Moderate
GE dE Refrigerator Defrost cycle timeout (evaporator frost buildup) Defrost heater 20 - 40 Ohms; bimetal 0 Ohms Moderate
GE PF-FR Refrigerator Power failure warning on dispenser panel 120V AC supply verify Low
LG E1 Washer Water leak detected in basepan (FloodSafe / AquaStop) Base float switch continuity Moderate
LG E3 Washer Load sensing error on older LG top/front loaders Hall sensor / tach check Moderate
LG tE4 Dryer Dryer moisture or condenser thermistor fault Thermistor ~10k Ohms at 77 deg F Moderate
LG PF Dryer Power failure interrupted drying 240V L1-L2 panel breaker verify Low
LG CL Dryer Child Lock enabled on dryer display No fault coil Low
LG 1E Refrigerator Freezer / defrost thermistor failure Thermistor ~10k - 30k Ohms Moderate
LG CL Dishwasher Child Lock active on dishwasher panel No fault coil Low
LG F-7 Oven / Range Self-clean door lock switch fault Door lock motor & microswitch check Moderate
Samsung PF Washer Power failure during active wash cycle 120V AC outlet verify Low
Samsung SF Washer System / main PCB internal relay fault 120V AC feed verify Pro Required
Samsung 4E2 Washer Hot water supply connected to cold port (>122 F) No part fault Low
Samsung 8E / 8C Washer MEMS vibration sensor error on VRT drum MEMS sensor 5V DC feed & harness Moderate
Samsung AC / AC6 Washer Inverter to main PCB communication error Serial comms harness continuity Pro Required
Samsung bE2 Washer Stuck button on control panel (>30s) Keypad continuity check Moderate
Samsung PC Dishwasher Zone-wash diverter / distribution motor error Zone motor & optical switch check Moderate
Samsung C-31 Oven / Range Main PCB over-temperature alert (>185 F ambient) Cooling blower & rear vent check Pro Required
Frigidaire E10 Washer Water supply fill timeout (slow fill) Inlet solenoids 800 - 1,300 Ohms Low
Frigidaire E22 Washer Slow drain / partial sump blockage Drain pump 12 - 22 Ohms Low
Frigidaire E32 Washer Pressure sensor calibration drift during spin Air trap tube clear Moderate
Frigidaire E35 Washer Water overfill detected above safe limit Inlet valve seat & pressure switch Moderate
Frigidaire E44 Washer Door lock sensing circuit failure on board Door lock switch 0 Ohms closed Pro Required
Frigidaire E51 Washer Motor power triac shorted on speed control Motor windings ~5 - 15 Ohms Pro Required
Frigidaire E52 Washer No tachometer signal from motor Tach coil ~115 - 170 Ohms Moderate
Frigidaire E66 Washer Wash water heater relay fault Heater coil 20 - 35 Ohms Pro Required
Frigidaire E71 Washer Wash NTC thermistor open or shorted Thermistor ~10k - 50k Ohms Moderate
Frigidaire E61 Dryer Heater relay failure on dryer main control Heater coil 8 - 14 Ohms Pro Required
Frigidaire E91 Dryer UI to main control communication error UI harness continuity Pro Required
Frigidaire Er Dishwasher Membrane keypad / communication error UI ribbon continuity check Moderate
Frigidaire 5Y Refrigerator Display communication/SY code variant Door hinge harness continuity Pro Required
Frigidaire F14 Oven / Range Shorted keypad or touchpad cable fault Keypad matrix open check Moderate
Bosch E03 Dishwasher Auxiliary / water-softener or heat relay fault Main board & valve check Pro Required
Bosch E07 Dishwasher Zeolite drying fan / heater circuit fault Zeolite blower motor check Pro Required
Bosch E10 Dishwasher Heat pump scaling or heating element slow rise Heat pump heater ~10 - 20 Ohms Moderate
Bosch E12 Dishwasher Calcified heat pump / mineral scale buildup Heat pump heater ~10 - 20 Ohms Moderate
Bosch E16 Dishwasher Water inlet valve failed to close (continuous fill) Inlet valve solenoid check Moderate
Bosch E20 Dishwasher Circulation pump winding resistance out of spec 3-phase wash motor ~30 - 60 Ohms/pair Pro Required
Bosch E21 Dishwasher Circulation pump rotor mechanically jammed 3-phase motor ~30 - 60 Ohms/pair Moderate
Bosch E23 Dishwasher Drain pump electrical open or phase imbalance 3-phase drain pump ~75 - 105 Ohms/pair Moderate
Maytag E1 Washer Inlet / pressure sensor error on Maxima/Neptune Pressure switch air tube clear Moderate
Maytag E2 Washer Drain pump timeout on legacy Maytag washer Drain pump 10 - 22 Ohms Low
Maytag HE Dryer Heating / thermal cutoff fault on Bravos/Maxima Heater 8 - 14 Ohms; fuse 0 - 1.5 Ohms Moderate
Maytag F3 E0 Dishwasher OWI turbidity / water temp sensor fault Thermistor ~45k - 55k Ohms Moderate
Maytag F1 E1 Dishwasher Main dishwasher control board relay fault 120V AC feed verify Pro Required
KitchenAid Er Refrigerator Communication or sensor fault on KitchenAid display Thermistor & hinge harness check Moderate
KitchenAid CF Refrigerator Cooling / condenser fan airflow alert 12V DC condenser fan check Moderate
Amana F2 E1 Washer Stuck key on washer control console UI ribbon continuity check Moderate
Amana F3 E1 Washer Water level pressure sensor out of range Pressure hose clear Moderate
Amana Sd Washer Excessive suds detected during wash No part fault Low
Amana AF Dryer Airflow restriction warning in exhaust vent IRC M1502 <= 35 ft rigid duct Low

FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

How do multimeter Ohm specs isolate faulty appliance components?

With AC power unplugged and capacitors discharged, technicians compare terminal resistance against OEM windows: 10-25 Ohms for drain pumps, 800-1,400 Ohms for inlet valves, and 0-1.5 Ohms for thermal fuses.

What does a 0-1.5 Ohm reading mean on a dryer thermal fuse?

A reading between 0 and 1.5 Ohms indicates intact closed continuity; an infinite (OL) reading confirms a blown thermal cutoff caused by restricted rigid-metal dryer venting.

Why must garage door opener error codes avoid tension spring adjustments?

Opener flash codes often follow mechanical binding; if a wound torsion spring above the door has a gap, keep the door closed and call a trained technician.

How can homeowners verify if a fault code requires a licensed pro?

CodeBench separates low-hazard cleaning and continuity checks from Pro Required tiers involving 240V heating circuits, gas ignition manifolds, R-600a cooling lines, and torsion springs.

Can unplugging an appliance permanently fix an OEM error code?

A 60-second breaker reset clears transient logic lockups only; failing pumps, open thermal fuses, or misaligned 16 CFR 1211 photo-eyes will re-trigger the fault.

What thermistor resistance should an oven RTD sensor show at room temperature?

Standard residential oven RTD temperature probes read approximately 1,050 to 1,120 Ohms at 70 F, whereas refrigerator NTC thermistors typically test near 10,000 Ohms at 77 F.

When is repairing an error code NOT economical out of warranty?

Once an appliance exceeds half its NAHB median lifespan (13 yrs fridge/dryer, 10 yrs washer, 9 yrs dishwasher), board or motor quotes above 50% replacement cost favor upgrading.

Who should NOT use CodeBench error code tolerances for commercial units?

Resistance ranges and NAHB age guidelines apply exclusively to 120V/240V residential out-of-warranty appliances, residential openers, and residential smart deadbolts.

Related guides

Sources

  1. OEM Service & Owner Manuals (GE, Whirlpool, LG, Samsung, Frigidaire, Bosch, Speed Queen, LiftMaster, Chamberlain, Genie, Wayne Dalton, Schlage, Kwikset) — Respective Equipment Manufacturers, 2020-2026 OEM Technical Publications (retrieved 2026-11-23)
  2. 16 CFR Part 1211 - Safety Standard for Automatic Residential Garage Door Operators — U.S. Consumer Product Safety Commission / eCFR, 2026-11-18 (retrieved 2026-11-23)
  3. International Residential Code (IRC) Section M1502.4.5 - Dryer Exhaust Ducts — International Code Council (ICC), IRC 2021 / 2024 (retrieved 2026-11-23)