Skip to main content
GE Fault Chart

GE Error Codes & Multimeter Reference (41 Codes)

Look up all 41 verified GE fault, blink, and warning codes across Dishwasher, Dryer, Oven / Range, Refrigerator, Washer. Each code entry details plain-English meanings, isolated multimeter Ohm ranges, common failing components, typical U.S. out-of-warranty repair cost bands, and safe DIY vs licensed technician limits. All figures come directly from EPA ENERGY STAR, EIA utility records, CPSC and NHTSA safety recalls, federal safety standards, Bureau of Labor Statistics wages, and public state licensing boards for U.S. out-of-warranty home repairs.

GE Error Codes
41
Systems Covered
Dishwasher, Dryer, Oven / Range, Refrigerator, Washer
Pro-Escalation Codes
6 of 41
Catalog Reference
414 total US codes

Which manufacturer error code directories are indexed?

Jump straight to any of the 15 major residential appliance, garage door opener, and smart deadbolt brands below for complete fault definitions and component repair cost bands.

How do your multimeter Ohm readings compare against OEM tolerances?

Disconnect AC power and discharge high-voltage capacitors first, then select a component to test drain pumps (10-25 Ohms), inlet valves, thermal fuses, or NTC sensors.

  • LG / Samsung Drain Pump (10 - 25 Ohms)
  • Water Inlet Solenoid (800 - 1,400 Ohms)
  • Dryer Thermal Fuse (0 - 1.5 Ohms)
  • Dryer Heating Element (8 - 14 Ohms)
  • Oven RTD Sensor @ 70 F (1,050 - 1,120 Ohms)
  • NTC Thermistor @ 77 F (9,000 - 11,000 Ohms)

Which appliance fault tiers are safe for DIY vs pro escalation?

CodeBench separates accessible filter and continuity checks from hazardous sealed-refrigerant lines, 240V relays, gas manifolds, and preloaded garage door torsion springs.

Low Hazard
Coin trap cleaning, inlet screens, sensor alignment, alkaline battery swaps.
Moderate Hazard
Unplugged thermistor / pump ohm tests, AquaStop sump pan checks.
Pro Required
240V oven relays, gas valves, R-600a sealed cooling, garage torsion springs.

Which verified OEM error and blink codes are indexed?

41 codes

Filter 41 documented error, blink, and keypad fault codes across major residential washer, dryer, dishwasher, opener, and lock platforms with multimeter specs.

Verified OEM fault and blink codes with multimeter Ohm test specifications and hazard classification
Brand & CodeSystemDefinitionOhm / Test SpecHazard
GE C1 / H2O Dishwasher Water supply fault or turbidity/float pressure switch timeout Inlet valve coil ~900 - 1,400 Ohms Low
GE F2 Oven / Range Oven cavity over-temperature detected (>615 deg F unlocked / >930 deg F clean) RTD sensor ~1,080 - 1,100 Ohms at 70 deg F Pro Required
GE E22 Washer Fill timeout: cold water valve slow or blocked Inlet valve solenoid ~900 - 1,300 Ohms Low
GE E23 Washer Fill timeout: hot water valve slow or blocked Inlet valve solenoid ~900 - 1,300 Ohms Low
GE E31 Washer Drain pump failed to evacuate tub within 6 minutes Drain pump winding 10 - 25 Ohms Low
GE E38 Washer Severe unbalanced load during spin cycle Suspension / balance ring check Low
GE E39 Washer Dispenser diverter motor fault Dispenser motor resistance check Moderate
GE E46 Washer Inverter / drive motor over-temperature cutoff Motor phase windings ~5 - 15 Ohms Pro Required
GE E60 Washer Door lock switch failed to latch Lock solenoid ~60 - 120 Ohms; switch 0 Ohms Moderate
GE E61 Washer Door failed to unlock after spin stop Door lock release solenoid check Moderate
GE E60-DR Dryer Exhaust thermistor temperature reading error Thermistor ~10k Ohms at 77 deg F Moderate
GE E61-DR Dryer Dryer inlet thermistor or thermostat out of range High-limit thermostat 0 Ohms closed Moderate
GE E64 Dryer Heater relay stuck or element grounded to cabinet Heating element 8 - 14 Ohms; OL to ground Pro Required
GE E65 Dryer Moisture sensor bars open or shorted Sensor bars open when dry (infinite Ohms) Low
GE tO Dryer Timed dry or vent restriction timeout IRC M1502 <= 35 ft rigid duct Low
GE F96 Dishwasher Dishwasher circulation motor or turbidity timeout Circulation motor ~10 - 25 Ohms Moderate
GE F97 Dishwasher Water heating failed to rise during wash cycle Heating element 10 - 30 Ohms Moderate
GE F98 Dishwasher Drain motor failed to empty sump Drain pump 12 - 25 Ohms Low
GE LOC Dishwasher Control Lock (Child Lock) enabled on touchpad No fault coil (button lock active) Low
GE dE Dishwasher Door latch switch open during cycle start Door latch switch 0 Ohms closed Moderate
GE FF Refrigerator Freezer evaporator fan speed or frost blockage alert 12V DC fan motor continuity check Moderate
GE HRS Refrigerator Run time exceeded without reaching target cooling temp Thermistor ~10k Ohms @ 77 F; R-600a rules Pro Required
GE CC Refrigerator Check Controls / cooling loss (>15 deg F rise) Thermistor & defrost heater 15 - 35 Ohms Moderate
GE CI Refrigerator Check Ice Maker sensor or stalled ejector arm Ice maker heater & thermistor check Low
GE PF Refrigerator Power failure alert on refrigerator display 120V AC receptacle verify Low
GE F0 Oven / Range Stuck Cancel/Off key or UI touch short Keypad membrane continuity check Moderate
GE F3 Oven / Range Oven cavity temperature sensor open circuit RTD probe 1,050 - 1,120 Ohms at 70 deg F Moderate
GE F4 Oven / Range Oven temperature sensor shorted (<800 Ohms) RTD probe ~1,080 Ohms at 70 deg F Moderate
GE F5 Oven / Range Watchdog / internal control microprocessor fault 120V/240V terminal supply verify Pro Required
GE F7 Oven / Range Function key stuck on keypad Membrane ribbon open check Moderate
GE F9 Oven / Range Oven door lock failed to latch during self-clean Lock motor ~1,500 - 2,500 Ohms Moderate
GE E11 Washer Water fill timeout (slow or no water entry) Inlet solenoids ~900 - 1,300 Ohms Low
GE E21 Washer Main drain timeout (>6 minutes) Drain pump 10 - 25 Ohms Low
GE E26 Washer Water level pressure sensor out of range Pressure sensor hose clear Moderate
GE E33 Washer Drive motor thermal overload or locked rotor Motor phase windings ~5 - 15 Ohms Moderate
GE E45 Washer Inverter communication or tachometer signal fault Tach / Hall sensor check Pro Required
GE E1 Dryer Thermistor temperature sensor open circuit Thermistor ~10k Ohms at 77 deg F Moderate
GE E2 Dryer Thermistor temperature sensor shorted Thermistor ~10k Ohms at 77 deg F Moderate
GE E3 Dryer High-limit thermostat or exhaust over-temp trip High-limit thermostat 0 Ohms closed Moderate
GE dE Refrigerator Defrost cycle timeout (evaporator frost buildup) Defrost heater 20 - 40 Ohms; bimetal 0 Ohms Moderate
GE PF-FR Refrigerator Power failure warning on dispenser panel 120V AC supply verify Low

FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

How do multimeter Ohm specs isolate faulty appliance components?

With AC power unplugged and capacitors discharged, technicians compare terminal resistance against OEM windows: 10-25 Ohms for drain pumps, 800-1,400 Ohms for inlet valves, and 0-1.5 Ohms for thermal fuses.

What does a 0-1.5 Ohm reading mean on a dryer thermal fuse?

A reading between 0 and 1.5 Ohms indicates intact closed continuity; an infinite (OL) reading confirms a blown thermal cutoff caused by restricted rigid-metal dryer venting.

Why must garage door opener error codes avoid tension spring adjustments?

Opener flash codes often follow mechanical binding; if a wound torsion spring above the door has a gap, keep the door closed and call a trained technician.

How can homeowners verify if a fault code requires a licensed pro?

CodeBench separates low-hazard cleaning and continuity checks from Pro Required tiers involving 240V heating circuits, gas ignition manifolds, R-600a cooling lines, and torsion springs.

Can unplugging an appliance permanently fix an OEM error code?

A 60-second breaker reset clears transient logic lockups only; failing pumps, open thermal fuses, or misaligned 16 CFR 1211 photo-eyes will re-trigger the fault.

What thermistor resistance should an oven RTD sensor show at room temperature?

Standard residential oven RTD temperature probes read approximately 1,050 to 1,120 Ohms at 70 F, whereas refrigerator NTC thermistors typically test near 10,000 Ohms at 77 F.

When is repairing an error code NOT economical out of warranty?

Once an appliance exceeds half its NAHB median lifespan (13 yrs fridge/dryer, 10 yrs washer, 9 yrs dishwasher), board or motor quotes above 50% replacement cost favor upgrading.

Who should NOT use CodeBench error code tolerances for commercial units?

Resistance ranges and NAHB age guidelines apply exclusively to 120V/240V residential out-of-warranty appliances, residential openers, and residential smart deadbolts.

Related guides

Sources

  1. OEM Service & Owner Manuals (GE, Whirlpool, LG, Samsung, Frigidaire, Bosch, Speed Queen, LiftMaster, Chamberlain, Genie, Wayne Dalton, Schlage, Kwikset) — Respective Equipment Manufacturers, 2020-2026 OEM Technical Publications (retrieved 2026-11-23)
  2. 16 CFR Part 1211 - Safety Standard for Automatic Residential Garage Door Operators — U.S. Consumer Product Safety Commission / eCFR, 2026-11-18 (retrieved 2026-11-23)
  3. International Residential Code (IRC) Section M1502.4.5 - Dryer Exhaust Ducts — International Code Council (ICC), IRC 2021 / 2024 (retrieved 2026-11-23)