LG Error Codes & Multimeter Reference (56 Codes)
Look up all 56 verified LG fault, blink, and warning codes across Dishwasher, Dryer, Oven / Range, Refrigerator, Washer. Each code entry details plain-English meanings, isolated multimeter Ohm ranges, common failing components, typical U.S. out-of-warranty repair cost bands, and safe DIY vs licensed technician limits. All figures come directly from EPA ENERGY STAR, EIA utility records, CPSC and NHTSA safety recalls, federal safety standards, Bureau of Labor Statistics wages, and public state licensing boards for U.S. out-of-warranty home repairs.
- LG Error Codes
- 56
- Systems Covered
- Dishwasher, Dryer, Oven / Range, Refrigerator, Washer
- Pro-Escalation Codes
- 5 of 56
- Catalog Reference
- 414 total US codes
Which manufacturer error code directories are indexed?
Jump straight to any of the 15 major residential appliance, garage door opener, and smart deadbolt brands below for complete fault definitions and component repair cost bands.
-
Amana 12 codes
Dryer, Oven / Range, Washer -
Bosch 32 codes
Dishwasher, Dryer, Washer -
Frigidaire 53 codes
Dishwasher, Dryer, Oven / Range, Refrigerator, Washer -
GE 41 codes
Dishwasher, Dryer, Oven / Range, Refrigerator, Washer -
Genie 8 codes
Garage Door Opener -
Kenmore 14 codes
Dishwasher (587. Frigidaire OEM), Oven / Range (790. Frigidaire OEM), Refrigerator (795. LG OEM), Washer (110. Whirlpool OEM), Washer (417. Frigidaire OEM) -
KitchenAid 20 codes
Dishwasher, Oven / Range, Refrigerator -
Kwikset 3 codes
SmartCode Deadbolt -
LG 56 codes
Dishwasher, Dryer, Oven / Range, Refrigerator, Washer -
LiftMaster / Chamberlain 16 codes
Garage Door Opener -
Maytag 27 codes
Dishwasher, Dryer, Oven / Range, Washer -
Samsung 57 codes
Dishwasher, Dryer, Oven / Range, Refrigerator, Washer -
Schlage 3 codes
Smart Deadbolt -
Speed Queen 13 codes
Dryer, Washer -
Whirlpool 59 codes
Dishwasher, Dryer, Oven / Range, Refrigerator, Washer
How do your multimeter Ohm readings compare against OEM tolerances?
Disconnect AC power and discharge high-voltage capacitors first, then select a component to test drain pumps (10-25 Ohms), inlet valves, thermal fuses, or NTC sensors.
Which appliance fault tiers are safe for DIY vs pro escalation?
CodeBench separates accessible filter and continuity checks from hazardous sealed-refrigerant lines, 240V relays, gas manifolds, and preloaded garage door torsion springs.
- Low Hazard
- Coin trap cleaning, inlet screens, sensor alignment, alkaline battery swaps.
- Moderate Hazard
- Unplugged thermistor / pump ohm tests, AquaStop sump pan checks.
- Pro Required
- 240V oven relays, gas valves, R-600a sealed cooling, garage torsion springs.
Which verified OEM error and blink codes are indexed?
56 codesFilter 56 documented error, blink, and keypad fault codes across major residential washer, dryer, dishwasher, opener, and lock platforms with multimeter specs.
| Brand & Code | System | Definition | Ohm / Test Spec | Hazard |
|---|---|---|---|---|
| LG OE | Washer | Drain pump timeout: washer did not drain within 10 minutes | 10 - 25 Ohms at drain pump motor terminals | Low |
| LG IE | Washer | Water inlet timeout: drum did not reach fill level within 8 minutes | 800 - 1,200 Ohms at water inlet solenoid coils | Low |
| LG UE | Washer | Unbalanced drum load detected during spin ramp | Hall sensor tach & balance check (no static coil Ohm spec) | Low |
| LG dE | Washer | Door lock switch failed to latch within 15 seconds | Door lock PTC coil ~60 - 120 Ohms; latch switch 0 Ohms closed | Moderate |
| LG d80 | Dryer | 80% exhaust duct blockage detected by Flow Sense pressure/temp curve | Thermistor ~10k Ohms at 77 deg F (25 C) | Moderate |
| LG Er IF | Refrigerator | Ice fan (freezer ice maker blower) motor speed error or ice buildup | 12V DC fan motor continuity check (no open winding) | Moderate |
| LG dE1 | Washer | Door switch open or failed to sense closed | Latch switch 0 Ohms closed | Moderate |
| LG dE2 | Washer | Door lock motor failed to lock after closing | Lock PTC coil ~60 - 120 Ohms | Moderate |
| LG LE | Washer | Locked motor error: drum rotor overloaded or Hall sensor open | Stator ~5 - 15 Ohms/phase; Hall sensor ~10k | Moderate |
| LG FE | Washer | Water overfill error: inlet valve failed to shut off | Water inlet coils 800 - 1,200 Ohms | Moderate |
| LG PE | Washer | Water level pressure switch out of range | Pressure switch pin voltage / air hose clear | Moderate |
| LG tE | Washer | Wash water thermistor open or shorted | Thermistor ~48k Ohms at 68 deg F | Moderate |
| LG CE | Washer | Over-current fault on Direct Drive motor inverter | Stator windings ~5 - 15 Ohms balanced | Pro Required |
| LG PF | Washer | Power failure interrupted active wash cycle | 120V AC outlet verify | Low |
| LG CL | Washer | Child Lock active (controls locked) | No fault coil (button lock active) | Low |
| LG Sud | Washer | Excessive suds detected in tub | No fault coil | Low |
| LG CD | Washer | Cool Down phase running (high-temp cycle end) | Normal operation indicator | Low |
| LG E6 | Washer | Clutch / hall sensor engagement fault on top-loader | Clutch coil & Hall sensor check | Moderate |
| LG d90 | Dryer | 90% exhaust duct blockage detected by Flow Sense | Thermistor ~10k Ohms @ 77 F | Moderate |
| LG d95 | Dryer | 95% severe exhaust airflow restriction (heater shuts off) | Thermal cutoff 0 - 1.5 Ohms | Moderate |
| LG tE1 | Dryer | Dryer outlet thermistor open or out of range | Thermistor ~10k Ohms at 77 deg F | Moderate |
| LG tE2 | Dryer | Dryer thermistor shorted (<500 Ohms) | Thermistor ~10k Ohms at 77 deg F | Moderate |
| LG tE3 | Dryer | Secondary / steam thermistor fault | Thermistor ~10k Ohms at 77 deg F | Moderate |
| LG nP | Dryer | No Power on L2 heater leg (240V supply fault) | 240V L1-L2 across terminal block | Pro Required |
| LG E1 | Dryer | Gas ignition or thermostat cutoff timeout | Gas valve coils ~1,200 - 1,400 Ohms | Pro Required |
| LG Er FF | Refrigerator | Freezer fan motor feedback error | 12V DC fan motor continuity | Moderate |
| LG Er rF | Refrigerator | Fresh food refrigerator fan motor error | 12V DC fan motor continuity | Moderate |
| LG Er CF | Refrigerator | Condenser fan motor error behind lower rear cover | 12V DC condenser fan check | Moderate |
| LG Er dH | Refrigerator | Defrost heater timeout (evaporator did not reach 45 F) | Defrost heater 20 - 40 Ohms; fuse 0 Ohms | Moderate |
| LG Er FS | Refrigerator | Freezer thermistor open or shorted | Thermistor ~10k - 30k Ohms (temp dependent) | Moderate |
| LG Er rS | Refrigerator | Fresh food compartment thermistor error | Thermistor ~10k Ohms at 77 deg F | Moderate |
| LG Er IS | Refrigerator | Ice maker sensor / ice fan assembly error | Ice thermistor & motor check | Moderate |
| LG Er gF | Refrigerator | Water flowmeter sensor failed to detect pulses | Flowmeter Hall pulse check | Moderate |
| LG Er CO | Refrigerator | Communication error between main PCB and display PCB | Door hinge wire harness continuity | Pro Required |
| LG OE | Dishwasher | Dishwasher drain timeout (>5 minutes) | Drain pump 15 - 30 Ohms | Low |
| LG IE | Dishwasher | Water inlet timeout in dishwasher | Inlet valve solenoid 800 - 1,300 Ohms | Low |
| LG AE | Dishwasher | Aqua-Stop basepan leak sensor triggered | Float microswitch continuity | Moderate |
| LG LE | Dishwasher | Wash motor locked rotor or inverter fault | Direct Drive wash motor ~5 - 15 Ohms | Moderate |
| LG HE | Dishwasher | Water heating element or relay fault | Heater coil 10 - 25 Ohms | Moderate |
| LG tE | Dishwasher | Wash water thermistor error | Thermistor ~10k - 50k Ohms | Moderate |
| LG FE | Dishwasher | Overfill detected in dishwasher tub | Inlet valve seat & flowmeter check | Moderate |
| LG nE | Dishwasher | Vario spray-arm diverter motor position error | Diverter microswitch & motor check | Moderate |
| LG F-1 | Oven / Range | Oven cavity temperature sensor open circuit | RTD probe ~1,080 Ohms at 70 deg F | Moderate |
| LG F-2 | Oven / Range | Oven RTD sensor shorted | RTD probe ~1,080 Ohms at 70 deg F | Moderate |
| LG F-3 | Oven / Range | Touchpad / control key shorted >60 seconds | Keypad matrix continuity check | Moderate |
| LG F-6 | Oven / Range | Oven cavity over-temperature fault | RTD probe ~1,080 Ohms at 70 deg F | Pro Required |
| LG F-9 | Oven / Range | Oven failed to heat within 5 minutes of bake start | Bake element 15 - 35 Ohms (electric) | Moderate |
| LG F-11 | Oven / Range | No temperature rise in upper/lower oven cavity | Bake/Broil element 15 - 35 Ohms | Moderate |
| LG E1 | Washer | Water leak detected in basepan (FloodSafe / AquaStop) | Base float switch continuity | Moderate |
| LG E3 | Washer | Load sensing error on older LG top/front loaders | Hall sensor / tach check | Moderate |
| LG tE4 | Dryer | Dryer moisture or condenser thermistor fault | Thermistor ~10k Ohms at 77 deg F | Moderate |
| LG PF | Dryer | Power failure interrupted drying | 240V L1-L2 panel breaker verify | Low |
| LG CL | Dryer | Child Lock enabled on dryer display | No fault coil | Low |
| LG 1E | Refrigerator | Freezer / defrost thermistor failure | Thermistor ~10k - 30k Ohms | Moderate |
| LG CL | Dishwasher | Child Lock active on dishwasher panel | No fault coil | Low |
| LG F-7 | Oven / Range | Self-clean door lock switch fault | Door lock motor & microswitch check | Moderate |
FAQ
Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.
How do multimeter Ohm specs isolate faulty appliance components?
With AC power unplugged and capacitors discharged, technicians compare terminal resistance against OEM windows: 10-25 Ohms for drain pumps, 800-1,400 Ohms for inlet valves, and 0-1.5 Ohms for thermal fuses.
What does a 0-1.5 Ohm reading mean on a dryer thermal fuse?
A reading between 0 and 1.5 Ohms indicates intact closed continuity; an infinite (OL) reading confirms a blown thermal cutoff caused by restricted rigid-metal dryer venting.
Why must garage door opener error codes avoid tension spring adjustments?
Opener flash codes often follow mechanical binding; if a wound torsion spring above the door has a gap, keep the door closed and call a trained technician.
How can homeowners verify if a fault code requires a licensed pro?
CodeBench separates low-hazard cleaning and continuity checks from Pro Required tiers involving 240V heating circuits, gas ignition manifolds, R-600a cooling lines, and torsion springs.
Can unplugging an appliance permanently fix an OEM error code?
A 60-second breaker reset clears transient logic lockups only; failing pumps, open thermal fuses, or misaligned 16 CFR 1211 photo-eyes will re-trigger the fault.
What thermistor resistance should an oven RTD sensor show at room temperature?
Standard residential oven RTD temperature probes read approximately 1,050 to 1,120 Ohms at 70 F, whereas refrigerator NTC thermistors typically test near 10,000 Ohms at 77 F.
When is repairing an error code NOT economical out of warranty?
Once an appliance exceeds half its NAHB median lifespan (13 yrs fridge/dryer, 10 yrs washer, 9 yrs dishwasher), board or motor quotes above 50% replacement cost favor upgrading.
Who should NOT use CodeBench error code tolerances for commercial units?
Resistance ranges and NAHB age guidelines apply exclusively to 120V/240V residential out-of-warranty appliances, residential openers, and residential smart deadbolts.
Related guides
Sources
- OEM Service & Owner Manuals (GE, Whirlpool, LG, Samsung, Frigidaire, Bosch, Speed Queen, LiftMaster, Chamberlain, Genie, Wayne Dalton, Schlage, Kwikset) — Respective Equipment Manufacturers, 2020-2026 OEM Technical Publications (retrieved 2026-11-23)
- 16 CFR Part 1211 - Safety Standard for Automatic Residential Garage Door Operators — U.S. Consumer Product Safety Commission / eCFR, 2026-11-18 (retrieved 2026-11-23)
- International Residential Code (IRC) Section M1502.4.5 - Dryer Exhaust Ducts — International Code Council (ICC), IRC 2021 / 2024 (retrieved 2026-11-23)