Disconnect AC power at the main breaker panel and discharge high-voltage capacitors before taking multimeter continuity or resistance readings. Select a residential component below to compare measured Ohms against verified OEM factory pass/fail tolerance windows across all 25 fault entries. All figures come directly from EPA ENERGY STAR, EIA utility records, CPSC and NHTSA safety recalls, federal safety standards, Bureau of Labor Statistics wages, and public state licensing boards for U.S. out-of-warranty home repairs.
- Drain Pump Spec
- 10-25 Ohms
- Water Inlet Solenoid
- 800-1,400 Ohms
- Dryer Thermal Fuse
- 0-1.5 Ohms (continuity)
- Oven RTD Sensor @ 70F
- 1,050-1,120 Ohms

How do your multimeter Ohm readings compare against OEM tolerances?
Disconnect AC power and discharge high-voltage capacitors first, then select a component to test drain pumps (10-25 Ohms), inlet valves, thermal fuses, or NTC sensors.
Which appliance fault tiers are safe for DIY vs pro escalation?
CodeBench separates accessible filter and continuity checks from hazardous sealed-refrigerant lines, 240V relays, gas manifolds, and preloaded garage door torsion springs.
- Low Hazard
- Coin trap cleaning, inlet screens, sensor alignment, alkaline battery swaps.
- Moderate Hazard
- Unplugged thermistor / pump ohm tests, AquaStop sump pan checks.
- Pro Required
- 240V oven relays, gas valves, R-600a sealed cooling, garage torsion springs.
Which verified OEM error and blink codes are indexed?
414 codesFilter 414 documented error, blink, and keypad fault codes across major residential washer, dryer, dishwasher, opener, and lock platforms with multimeter specs.
| Brand & Code | System | Definition | Ohm / Test Spec | Hazard |
|---|---|---|---|---|
| LG OE | Washer | Drain pump timeout: washer did not drain within 10 minutes | 10 - 25 Ohms at drain pump motor terminals | Low |
| LG IE | Washer | Water inlet timeout: drum did not reach fill level within 8 minutes | 800 - 1,200 Ohms at water inlet solenoid coils | Low |
| LG UE | Washer | Unbalanced drum load detected during spin ramp | Hall sensor tach & balance check (no static coil Ohm spec) | Low |
| LG dE | Washer | Door lock switch failed to latch within 15 seconds | Door lock PTC coil ~60 - 120 Ohms; latch switch 0 Ohms closed | Moderate |
| LG d80 | Dryer | 80% exhaust duct blockage detected by Flow Sense pressure/temp curve | Thermistor ~10k Ohms at 77 deg F (25 C) | Moderate |
| LG Er IF | Refrigerator | Ice fan (freezer ice maker blower) motor speed error or ice buildup | 12V DC fan motor continuity check (no open winding) | Moderate |
| Samsung 5E / SE | Washer | Drain error: water level sensor failed to drop within drain cycle window | 12 - 20 Ohms across drain pump motor terminals | Low |
| Samsung 4E / 4C | Washer | Water supply error: insufficient fill detected | 800 - 1,300 Ohms per inlet valve solenoid | Low |
| Samsung dC / dE | Washer | Door open or lock sensing failure during cycle start | 0 Ohms continuity across closed door switch contacts | Moderate |
| Samsung HC / HE | Dryer | Heater / overheating thermal cutoff error or shorted relay | Heating element 8 - 12 Ohms; thermal fuse 0 Ohms continuity | Moderate |
| Samsung LC / LE | Dishwasher | Leak sensor triggered in bottom sump drip pan | Float/leak sensor switch continuity open when dry | Moderate |
| Whirlpool F9 E1 | Washer | Long drain time exceeded (6+ minutes without pressure drop) | 10 - 20 Ohms on drain pump winding | Low |
| Whirlpool F5 E2 | Washer | Door lock fault: latch solenoid failed to lock or sense closed | Lock solenoid 60 - 110 Ohms; switch 0 Ohms locked | Moderate |
| Whirlpool F1 E0 | Oven / Range | EEPROM / main relay control board internal fault | Oven temp sensor ~1,080 Ohms at 70 deg F (separate verify) | Pro Required |
| GE C1 / H2O | Dishwasher | Water supply fault or turbidity/float pressure switch timeout | Inlet valve coil ~900 - 1,400 Ohms | Low |
| GE F2 | Oven / Range | Oven cavity over-temperature detected (>615 deg F unlocked / >930 deg F clean) | RTD sensor ~1,080 - 1,100 Ohms at 70 deg F | Pro Required |
| Frigidaire i20 | Dishwasher | Drain timeout fault (pressure sensor still detects standing water) | Drain pump ~15 - 25 Ohms; pressure sensor air trap clean | Low |
| Bosch E15 | Dishwasher | AquaStop basepan float switch triggered by internal water leak | Base float microswitch open circuit when dry | Moderate |
| Bosch E24 | Dishwasher | Drain hose blocked, kinked, or drain pump cover unlatched | 3-phase drain pump balanced windings ~75 - 105 Ohms per pair | Low |
| Speed Queen Er dL | Washer | Door lock timeout / latch sensing switch open | Door lock solenoid & switch continuity test at J-plug | Moderate |
| LiftMaster / Chamberlain 1 Up / 1 Down | Garage Door Opener | Safety reversing sensors wire open, disconnected, or misaligned | Low-voltage 2-wire DC loop (~6V DC pulse) | Low |
| LiftMaster / Chamberlain 4 Up / 1 Down | Garage Door Opener | Downward travel excess force sensed (door binds or spring broken) | RPM / travel module sensor pulse check | Pro Required |
| Genie Red Blink (Safe-T-Beam) | Garage Door Opener | Safe-T-Beam photo-eye misaligned, obstructed, or sunlight interference | Low-voltage Safe-T-Beam bus | Low |
| Schlage 2 Red Flashes (BE469/BE479) | Smart Deadbolt | Deadbolt throw obstructed or low battery voltage under motor load | 4x AA alkaline >= 5.6V resting | Low |
| Kwikset 10 Red Flashes | SmartCode Deadbolt | Low battery or door handing process incomplete | 4x AA alkaline >= 5.6V resting | Low |
| Whirlpool F0 E2 | Washer | Excessive suds detected during wash or spin phase | Pressure hose & drain pump 10 - 20 Ohms | Low |
| Whirlpool F0 E4 | Washer | High water temperature during spin cycle (>105 deg F) | Thermistor ~10k Ohms at 77 deg F | Low |
| Whirlpool F0 E5 | Washer | Off-balance load sensed during high-speed spin ramp | Suspension rod & tachometer speed check | Low |
| Whirlpool F1 E1 | Washer | Main control board (ACU) relay or internal memory fault | 120V AC supply verify at ACU J1 connector | Pro Required |
| Whirlpool F1 E2 | Washer | Motor control unit (MCU) voltage or thermal fault | Stator windings ~5 - 15 Ohms per phase pair | Pro Required |
| Whirlpool F2 E1 | Washer | Stuck keypad or capacitive touch button held >15 seconds | UI ribbon cable continuity check | Moderate |
| Whirlpool F3 E1 | Washer | Water level pressure sensor out of calibration range | Pressure switch frequency / air trap clear | Moderate |
| Whirlpool F3 E2 | Washer | Inlet water temperature thermistor open or shorted | NTC thermistor ~10k - 50k Ohms (temp dependent) | Moderate |
| Whirlpool F5 E1 | Washer | Lid/door switch open while attempting cycle start | 0 Ohms continuity across closed lid switch | Low |
| Whirlpool F5 E3 | Washer | Door lock failed to unlock after cycle completion | Lock solenoid 60 - 110 Ohms; PTC cool-down | Moderate |
| Whirlpool F6 E1 | Washer | Communication error between UI panel and ACU board | 5V DC / 12V DC harness continuity check | Pro Required |
| Whirlpool F6 E2 | Washer | Communication drop between UI and Motor Control Unit | Serial bus harness continuity (0 - 1 Ohm) | Pro Required |
| Whirlpool F6 E3 | Washer | ACU to MCU communication timeout | Harness continuity & 120V feed to MCU | Pro Required |
| Whirlpool F7 E1 | Washer | Basket speed tachometer fault (drum cannot track RPM) | Optical speed sensor / shift actuator ~2k Ohms | Moderate |
| Whirlpool F7 E5 | Washer | Shift actuator failed to engage agitate or spin spline | Shift actuator motor ~2,000 - 3,500 Ohms | Moderate |
| Whirlpool F7 E6 | Washer | Drive motor open winding or relay circuit fault | Motor start/run windings ~3 - 10 Ohms | Moderate |
| Whirlpool F7 E7 | Washer | Motor unable to reach target spin RPM | Drive belt tension & tach pulse check | Moderate |
| Whirlpool F8 E1 | Washer | No water fill or slow fill timeout (>8 minutes) | Water inlet solenoids 800 - 1,400 Ohms | Low |
| Whirlpool F8 E3 | Washer | Overflow / high water level sensed above safe threshold | Inlet valve seat seal & air tube check | Moderate |
| Whirlpool F9 E2 | Washer | Drain pump motor thermal overload or electrical open | Drain pump coil 10 - 20 Ohms | Low |
| Whirlpool Sd / Sud | Washer | Suds lock detected reducing spin extraction efficiency | No fault coil (detergent overuse lock) | Low |
| Whirlpool F1 | Dryer | Primary electronic control board relay failure | Relay board 120V/240V supply check | Pro Required |
| Whirlpool F2 | Dryer | Stuck keypad button on dryer user interface | Keypad ribbon matrix continuity check | Moderate |
| Whirlpool F3 E1 | Dryer | Outlet exhaust thermistor open circuit | Thermistor ~10k Ohms at 77 deg F (25 C) | Moderate |
| Whirlpool F3 E2 | Dryer | Outlet exhaust thermistor shorted (excess temp read) | Thermistor ~10k Ohms at 77 deg F (not <1k) | Moderate |
| Whirlpool F4 E3 | Dryer | Restricted airflow / thermal cutoff tripped | Thermal fuse 0 - 1.5 Ohms; heater 8 - 14 Ohms | Moderate |
| Whirlpool PF | Dryer | Power failure interrupted active drying cycle | 240V L1-L2 split-phase breaker check | Low |
| Whirlpool AF | Dryer | Airflow restriction warning (>75% duct blockage) | Rigid duct <= 35 ft (-5 ft per 90-deg elbow) | Low |
| Whirlpool F1 E1-DW | Dishwasher | Dishwasher main control board relay fault | Main board 120V AC feed check | Pro Required |
| Whirlpool F3 E1-DW | Dishwasher | OWI turbidity / water temperature sensor fault | Thermistor ~45k - 55k Ohms at 77 deg F | Moderate |
| Whirlpool F4 E3-DW | Dishwasher | Wash circulation motor not running or low current draw | Wash motor winding ~5 - 15 Ohms | Moderate |
| Whirlpool F6 E1-DW | Dishwasher | Control unable to communicate with UI console | UI ribbon continuity & 5V DC feed | Pro Required |
| Whirlpool F7 E1-DW | Dishwasher | Heating element circuit fault (water failed to heat) | Heating element 10 - 30 Ohms; hi-limit 0 Ohms | Moderate |
| Whirlpool F8 E4 | Dishwasher | Float switch / basepan overfill leak trip | Float microswitch 0 Ohms closed / OL open | Moderate |
| Whirlpool F9 E1-DW | Dishwasher | Dishwasher drain timeout or blocked disposal port | Drain pump 15 - 30 Ohms | Low |
| Whirlpool F9 E2-DW | Dishwasher | Drain pump electrical open or locked rotor | Drain pump coil 15 - 30 Ohms | Moderate |
| Whirlpool F1 E1-OV | Oven / Range | Range safety relay or oven control fault | RTD probe ~1,080 Ohms at 70 deg F | Pro Required |
| Whirlpool F2 E0 | Oven / Range | Keypad cable disconnected or shorted button | Keypad tail continuity test | Moderate |
| Whirlpool F2 E1-OV | Oven / Range | Cancel key or keypad matrix stuck >60 seconds | Keypad matrix open when unpressed | Moderate |
| Whirlpool F3 E0 | Oven / Range | Oven temperature sensor open or shorted | RTD sensor 1,050 - 1,120 Ohms at 70 deg F | Moderate |
| Whirlpool F3 E1-OV | Oven / Range | Oven cavity temperature sensor out of range | RTD sensor ~1,080 Ohms at 70 deg F | Moderate |
| Whirlpool F5 E0 | Oven / Range | Self-clean door latch switch open/closed conflict | Latch microswitch 0 Ohms closed | Moderate |
| Whirlpool F6 E0 | Oven / Range | Lost communication between UI and appliance manager | Harness continuity & 12V DC supply | Pro Required |
| Whirlpool F8 E0 | Oven / Range | Cooling fan speed too low during bake or clean | Cooling blower coil & Hall tach check | Pro Required |
| Whirlpool PO | Refrigerator | Power outage alert after AC supply interruption | 120V AC outlet voltage verify | Low |
| Maytag F0 E1 | Washer | Load detected in drum during clean-washer cycle | No sensor coil (basket must be empty) | Low |
| Maytag F5 E1 | Washer | Lid/door switch fails to register closed position | 0 Ohms closed across lid switch contacts | Low |
| Maytag F5 E2 | Washer | Door lock solenoid timeout on Maxima/Bravos | Lock coil 60 - 110 Ohms | Moderate |
| Maytag F7 E1 | Washer | Basket speed sensor / tach fault | Tachometer & shift actuator ~2k Ohms | Moderate |
| Maytag F8 E1 | Washer | Long fill timeout or cold/hot supply blocked | Water inlet coils 800 - 1,400 Ohms | Low |
| Maytag F9 E1 | Washer | Drain timeout exceeding 6 minutes | Drain pump motor 10 - 20 Ohms | Low |
| Maytag oL | Washer | Overloaded basket / motor current limit tripped | Drive motor windings ~3 - 10 Ohms | Low |
| Maytag uL | Washer | Unbalanced load during spin extraction | Suspension rod & leveling check | Low |
| Maytag dL | Washer | Door lock failed to engage within 3 tries | Lock solenoid 60 - 110 Ohms | Moderate |
| Maytag nd | Washer | No drain: tub pressure remained high after drain phase | Drain pump 10 - 20 Ohms | Low |
| Maytag nF | Washer | No fill: insufficient water entered within 8 minutes | Inlet valve solenoids 800 - 1,400 Ohms | Low |
| Maytag LO | Washer | Door failed to unlock after cycle stop | Door lock PTC & solenoid check | Moderate |
| Maytag Sd | Washer | Excessive suds preventing drain/spin transition | No part fault (excess detergent) | Low |
| Maytag PF | Washer | Power failure mid-cycle | 120V AC GFCI / breaker verify | Low |
| Maytag AF | Dryer | Restricted airflow detected on Bravos/Maxima dryer | IRC M1502 <= 35 ft rigid 4-in duct | Low |
| Maytag F1 | Dryer | Dryer control board heater relay fault | Main board relay test | Pro Required |
| Maytag F3 E1 | Dryer | Exhaust thermistor open circuit | Thermistor ~10k Ohms at 77 deg F | Moderate |
| Maytag F4 E3 | Dryer | Dryer thermal cutoff / restricted vent overheat | Thermal fuse 0 - 1.5 Ohms | Moderate |
| Maytag F8 E4 | Dishwasher | Overfill float / basepan water sensor tripped | Float switch 0 Ohms closed | Moderate |
| Maytag F9 E1 | Dishwasher | Long drain fault in dishwasher sump | Drain pump 15 - 30 Ohms | Low |
| Maytag F2 | Oven / Range | Oven cavity over-temperature fault | RTD probe ~1,080 Ohms at 70 deg F | Pro Required |
| Maytag F3 E0 | Oven / Range | Oven RTD sensor open or shorted | RTD probe 1,050 - 1,120 Ohms at 70 deg F | Moderate |
| KitchenAid 6-4 | Dishwasher | Float switch open / overfill water detected | Float switch 0 Ohms closed when resting | Moderate |
| KitchenAid 7-1 | Dishwasher | Heating element failed to raise wash water temperature | Heater coil 10 - 30 Ohms; hi-limit 0 Ohms | Moderate |
| KitchenAid 8-1 | Dishwasher | Slow drain / sump standing water at end of cycle | Drain pump 15 - 30 Ohms | Low |
| KitchenAid 8-2 | Dishwasher | Drain pump electrical open or stalled rotor | Drain pump winding 15 - 30 Ohms | Moderate |
| KitchenAid 9-1 | Dishwasher | Diverter motor failed to index spray arm position | Diverter motor ~1,200 - 2,000 Ohms | Moderate |
| KitchenAid F1 E1 | Dishwasher | Dishwasher main control board internal relay fault | 120V AC supply & board fuse check | Pro Required |
| KitchenAid F3 E1 | Dishwasher | OWI turbidity / temperature sensor out of calibration | Thermistor ~45k - 55k Ohms at 77 deg F | Moderate |
| KitchenAid F6 E1 | Dishwasher | UI touchpad to control communication lost | UI ribbon continuity check | Pro Required |
| KitchenAid F7 E1 | Dishwasher | Heater circuit open or stuck open relay | Heating element 10 - 30 Ohms | Moderate |
| KitchenAid F8 E4 | Dishwasher | Overfill / drip tray leak switch triggered | Drip tray switch continuity | Moderate |
| KitchenAid F9 E1 | Dishwasher | Drain cycle exceeded maximum timeout | Drain pump 15 - 30 Ohms | Low |
| KitchenAid F1 E0 | Oven / Range | EOC control board EEPROM or keypad relay fault | RTD check ~1,080 Ohms at 70 deg F | Pro Required |
| KitchenAid F2 E1 | Oven / Range | Stuck key detected on touch panel >60s | Keypad matrix open when idle | Moderate |
| KitchenAid F3 E0 | Oven / Range | Oven RTD sensor open or shorted | RTD probe 1,050 - 1,120 Ohms at 70 deg F | Moderate |
| KitchenAid F3 E1 | Oven / Range | Oven cavity temperature sensor fault | RTD probe ~1,080 Ohms at 70 deg F | Moderate |
| KitchenAid F5 E0 | Oven / Range | Door lock switch state mismatch during self-clean | Latch microswitch 0 Ohms closed | Moderate |
| KitchenAid F6 E0 | Oven / Range | Serial communication failure between UI and power board | Low-voltage comms harness continuity | Pro Required |
| KitchenAid PO | Refrigerator | Power outage alert indicator | 120V AC supply verify | Low |
| GE E22 | Washer | Fill timeout: cold water valve slow or blocked | Inlet valve solenoid ~900 - 1,300 Ohms | Low |
| GE E23 | Washer | Fill timeout: hot water valve slow or blocked | Inlet valve solenoid ~900 - 1,300 Ohms | Low |
| GE E31 | Washer | Drain pump failed to evacuate tub within 6 minutes | Drain pump winding 10 - 25 Ohms | Low |
| GE E38 | Washer | Severe unbalanced load during spin cycle | Suspension / balance ring check | Low |
| GE E39 | Washer | Dispenser diverter motor fault | Dispenser motor resistance check | Moderate |
| GE E46 | Washer | Inverter / drive motor over-temperature cutoff | Motor phase windings ~5 - 15 Ohms | Pro Required |
| GE E60 | Washer | Door lock switch failed to latch | Lock solenoid ~60 - 120 Ohms; switch 0 Ohms | Moderate |
| GE E61 | Washer | Door failed to unlock after spin stop | Door lock release solenoid check | Moderate |
| GE E60-DR | Dryer | Exhaust thermistor temperature reading error | Thermistor ~10k Ohms at 77 deg F | Moderate |
| GE E61-DR | Dryer | Dryer inlet thermistor or thermostat out of range | High-limit thermostat 0 Ohms closed | Moderate |
| GE E64 | Dryer | Heater relay stuck or element grounded to cabinet | Heating element 8 - 14 Ohms; OL to ground | Pro Required |
| GE E65 | Dryer | Moisture sensor bars open or shorted | Sensor bars open when dry (infinite Ohms) | Low |
| GE tO | Dryer | Timed dry or vent restriction timeout | IRC M1502 <= 35 ft rigid duct | Low |
| GE F96 | Dishwasher | Dishwasher circulation motor or turbidity timeout | Circulation motor ~10 - 25 Ohms | Moderate |
| GE F97 | Dishwasher | Water heating failed to rise during wash cycle | Heating element 10 - 30 Ohms | Moderate |
| GE F98 | Dishwasher | Drain motor failed to empty sump | Drain pump 12 - 25 Ohms | Low |
| GE LOC | Dishwasher | Control Lock (Child Lock) enabled on touchpad | No fault coil (button lock active) | Low |
| GE dE | Dishwasher | Door latch switch open during cycle start | Door latch switch 0 Ohms closed | Moderate |
| GE FF | Refrigerator | Freezer evaporator fan speed or frost blockage alert | 12V DC fan motor continuity check | Moderate |
| GE HRS | Refrigerator | Run time exceeded without reaching target cooling temp | Thermistor ~10k Ohms @ 77 F; R-600a rules | Pro Required |
| GE CC | Refrigerator | Check Controls / cooling loss (>15 deg F rise) | Thermistor & defrost heater 15 - 35 Ohms | Moderate |
| GE CI | Refrigerator | Check Ice Maker sensor or stalled ejector arm | Ice maker heater & thermistor check | Low |
| GE PF | Refrigerator | Power failure alert on refrigerator display | 120V AC receptacle verify | Low |
| GE F0 | Oven / Range | Stuck Cancel/Off key or UI touch short | Keypad membrane continuity check | Moderate |
| GE F3 | Oven / Range | Oven cavity temperature sensor open circuit | RTD probe 1,050 - 1,120 Ohms at 70 deg F | Moderate |
| GE F4 | Oven / Range | Oven temperature sensor shorted (<800 Ohms) | RTD probe ~1,080 Ohms at 70 deg F | Moderate |
| GE F5 | Oven / Range | Watchdog / internal control microprocessor fault | 120V/240V terminal supply verify | Pro Required |
| GE F7 | Oven / Range | Function key stuck on keypad | Membrane ribbon open check | Moderate |
| GE F9 | Oven / Range | Oven door lock failed to latch during self-clean | Lock motor ~1,500 - 2,500 Ohms | Moderate |
| LG dE1 | Washer | Door switch open or failed to sense closed | Latch switch 0 Ohms closed | Moderate |
| LG dE2 | Washer | Door lock motor failed to lock after closing | Lock PTC coil ~60 - 120 Ohms | Moderate |
| LG LE | Washer | Locked motor error: drum rotor overloaded or Hall sensor open | Stator ~5 - 15 Ohms/phase; Hall sensor ~10k | Moderate |
| LG FE | Washer | Water overfill error: inlet valve failed to shut off | Water inlet coils 800 - 1,200 Ohms | Moderate |
| LG PE | Washer | Water level pressure switch out of range | Pressure switch pin voltage / air hose clear | Moderate |
| LG tE | Washer | Wash water thermistor open or shorted | Thermistor ~48k Ohms at 68 deg F | Moderate |
| LG CE | Washer | Over-current fault on Direct Drive motor inverter | Stator windings ~5 - 15 Ohms balanced | Pro Required |
| LG PF | Washer | Power failure interrupted active wash cycle | 120V AC outlet verify | Low |
| LG CL | Washer | Child Lock active (controls locked) | No fault coil (button lock active) | Low |
| LG Sud | Washer | Excessive suds detected in tub | No fault coil | Low |
| LG CD | Washer | Cool Down phase running (high-temp cycle end) | Normal operation indicator | Low |
| LG E6 | Washer | Clutch / hall sensor engagement fault on top-loader | Clutch coil & Hall sensor check | Moderate |
| LG d90 | Dryer | 90% exhaust duct blockage detected by Flow Sense | Thermistor ~10k Ohms @ 77 F | Moderate |
| LG d95 | Dryer | 95% severe exhaust airflow restriction (heater shuts off) | Thermal cutoff 0 - 1.5 Ohms | Moderate |
| LG tE1 | Dryer | Dryer outlet thermistor open or out of range | Thermistor ~10k Ohms at 77 deg F | Moderate |
| LG tE2 | Dryer | Dryer thermistor shorted (<500 Ohms) | Thermistor ~10k Ohms at 77 deg F | Moderate |
| LG tE3 | Dryer | Secondary / steam thermistor fault | Thermistor ~10k Ohms at 77 deg F | Moderate |
| LG nP | Dryer | No Power on L2 heater leg (240V supply fault) | 240V L1-L2 across terminal block | Pro Required |
| LG E1 | Dryer | Gas ignition or thermostat cutoff timeout | Gas valve coils ~1,200 - 1,400 Ohms | Pro Required |
| LG Er FF | Refrigerator | Freezer fan motor feedback error | 12V DC fan motor continuity | Moderate |
| LG Er rF | Refrigerator | Fresh food refrigerator fan motor error | 12V DC fan motor continuity | Moderate |
| LG Er CF | Refrigerator | Condenser fan motor error behind lower rear cover | 12V DC condenser fan check | Moderate |
| LG Er dH | Refrigerator | Defrost heater timeout (evaporator did not reach 45 F) | Defrost heater 20 - 40 Ohms; fuse 0 Ohms | Moderate |
| LG Er FS | Refrigerator | Freezer thermistor open or shorted | Thermistor ~10k - 30k Ohms (temp dependent) | Moderate |
| LG Er rS | Refrigerator | Fresh food compartment thermistor error | Thermistor ~10k Ohms at 77 deg F | Moderate |
| LG Er IS | Refrigerator | Ice maker sensor / ice fan assembly error | Ice thermistor & motor check | Moderate |
| LG Er gF | Refrigerator | Water flowmeter sensor failed to detect pulses | Flowmeter Hall pulse check | Moderate |
| LG Er CO | Refrigerator | Communication error between main PCB and display PCB | Door hinge wire harness continuity | Pro Required |
| LG OE | Dishwasher | Dishwasher drain timeout (>5 minutes) | Drain pump 15 - 30 Ohms | Low |
| LG IE | Dishwasher | Water inlet timeout in dishwasher | Inlet valve solenoid 800 - 1,300 Ohms | Low |
| LG AE | Dishwasher | Aqua-Stop basepan leak sensor triggered | Float microswitch continuity | Moderate |
| LG LE | Dishwasher | Wash motor locked rotor or inverter fault | Direct Drive wash motor ~5 - 15 Ohms | Moderate |
| LG HE | Dishwasher | Water heating element or relay fault | Heater coil 10 - 25 Ohms | Moderate |
| LG tE | Dishwasher | Wash water thermistor error | Thermistor ~10k - 50k Ohms | Moderate |
| LG FE | Dishwasher | Overfill detected in dishwasher tub | Inlet valve seat & flowmeter check | Moderate |
| LG nE | Dishwasher | Vario spray-arm diverter motor position error | Diverter microswitch & motor check | Moderate |
| LG F-1 | Oven / Range | Oven cavity temperature sensor open circuit | RTD probe ~1,080 Ohms at 70 deg F | Moderate |
| LG F-2 | Oven / Range | Oven RTD sensor shorted | RTD probe ~1,080 Ohms at 70 deg F | Moderate |
| LG F-3 | Oven / Range | Touchpad / control key shorted >60 seconds | Keypad matrix continuity check | Moderate |
| LG F-6 | Oven / Range | Oven cavity over-temperature fault | RTD probe ~1,080 Ohms at 70 deg F | Pro Required |
| LG F-9 | Oven / Range | Oven failed to heat within 5 minutes of bake start | Bake element 15 - 35 Ohms (electric) | Moderate |
| LG F-11 | Oven / Range | No temperature rise in upper/lower oven cavity | Bake/Broil element 15 - 35 Ohms | Moderate |
| Samsung 5C | Washer | Drain timeout (modern Samsung code replacing 5E) | Drain pump 12 - 20 Ohms | Low |
| Samsung 4C2 | Washer | Cold supply hose connected to hot water >122 deg F | No part fault (hose swap) | Low |
| Samsung dC1 | Washer | Door lock latch failed to engage/release | Lock solenoid ~60 - 120 Ohms | Moderate |
| Samsung UB / UE | Washer | Unbalanced drum load during spin ramp | Suspension dampers & Hall sensor | Low |
| Samsung UR | Washer | Unbalanced spin retry active | Suspension dampers check | Low |
| Samsung LC | Washer | Water leak detected in washer basepan | Leak sensor switch continuity | Moderate |
| Samsung 1E / 1C | Washer | Water level pressure sensor fault | Pressure switch frequency check | Moderate |
| Samsung 3E / 3C | Washer | Drive motor Hall / tach speed fault | Stator ~5 - 15 Ohms/phase; Hall check | Moderate |
| Samsung tE | Washer | Water temperature thermistor error | Thermistor ~10k - 50k Ohms | Moderate |
| Samsung Sud | Washer | Excessive foam/suds detected during cycle | No part fault | Low |
| Samsung tE | Dryer | Dryer thermistor open or shorted | Thermistor ~10k Ohms at 77 deg F | Moderate |
| Samsung tO | Dryer | Dryer time-out / airflow restriction warning | IRC M1502 <= 35 ft rigid duct | Low |
| Samsung dE / dC | Dryer | Dryer door switch open during cycle start | Door switch 0 Ohms closed | Low |
| Samsung 9E1 / 9C1 | Dryer | Abnormal power voltage (<100V or >260V) detected | 240V L1-L2 at terminal block | Pro Required |
| Samsung bE | Dryer | Stuck control button (>30s pressed) | UI button membrane check | Moderate |
| Samsung FC | Dryer | Invalid power line frequency sensed | Main PCB & 60 Hz supply check | Pro Required |
| Samsung CL | Dryer | Vent / lint check reminder or Child Lock | No fault coil | Low |
| Samsung 1E | Refrigerator | Freezer / ice maker sensor open or shorted | Thermistor ~10k - 30k Ohms | Moderate |
| Samsung 5E | Refrigerator | Fresh-food defrost sensor open or shorted | Defrost thermistor ~5k - 15k Ohms | Moderate |
| Samsung 8E | Refrigerator | Ice maker sensor / auger error | Ice room thermistor check | Moderate |
| Samsung 21E | Refrigerator | Freezer evaporator fan motor error | 12V DC fan motor continuity | Moderate |
| Samsung 22E | Refrigerator | Fresh-food evaporator fan motor error (twin cooling) | 12V DC fan motor continuity | Moderate |
| Samsung 23E | Refrigerator | Condenser fan motor error at lower rear bay | 12V DC fan check | Moderate |
| Samsung 24E | Refrigerator | Freezer defrost failure (excess frost accumulation) | Defrost heater 20 - 45 Ohms; bimetal 0 Ohms | Moderate |
| Samsung 25E | Refrigerator | Fresh-food evaporator defrost failure | Defrost heater 25 - 50 Ohms; fuse 0 Ohms | Moderate |
| Samsung 26E | Refrigerator | Water valve or ice maker fill feedback error | Water inlet solenoid ~300 - 500 Ohms | Moderate |
| Samsung 33E | Refrigerator | Ice room water fill pipe heater open | Fill tube heater continuity check | Moderate |
| Samsung 39E | Refrigerator | Ice maker motor / test switch fault | Ice maker test switch check | Moderate |
| Samsung 40E | Refrigerator | Ice room cooling fan motor error | 12V DC ice fan check | Moderate |
| Samsung 84C | Refrigerator | Inverter compressor locked rotor / overload | Compressor windings balanced ~5 - 15 Ohms | Pro Required |
| Samsung PC Er | Refrigerator | Door-hinge communication error (display to main PCB) | Hinge harness continuity check | Pro Required |
| Samsung 4C | Dishwasher | Water supply timeout in dishwasher | Inlet solenoid 800 - 1,300 Ohms | Low |
| Samsung 5C | Dishwasher | Drain timeout in dishwasher | Drain pump 12 - 25 Ohms | Low |
| Samsung OC / oE | Dishwasher | Overfill water level error | Case brake / flowmeter & valve check | Moderate |
| Samsung HE | Dishwasher | Water heating element / relay error | Heater element 10 - 25 Ohms | Moderate |
| Samsung tE | Dishwasher | Sump temperature thermistor fault | Thermistor ~10k - 50k Ohms | Moderate |
| Samsung AP | Dishwasher | Wi-Fi Access Point pairing mode active | No fault coil | Low |
| Samsung SE | Oven / Range | Stuck key or shorted membrane touchpad | Keypad ribbon continuity | Moderate |
| Samsung C-20 | Oven / Range | Oven temperature sensor open or shorted | RTD probe ~1,080 Ohms at 70 deg F | Moderate |
| Samsung C-21 | Oven / Range | Oven cavity over-temperature fault | RTD probe ~1,080 Ohms at 70 deg F | Pro Required |
| Samsung C-30 | Oven / Range | Main PCB ambient temperature sensor fault | PCB cooling & ambient thermistor check | Pro Required |
| Samsung C-d0 | Oven / Range | Keypad button shorted >30 seconds | Keypad matrix open check | Moderate |
| Samsung C-d1 | Oven / Range | Self-clean door lock switch error | Door lock motor & switch continuity | Moderate |
| Samsung C-F0 | Oven / Range | Communication error between display and main PCB | Serial harness continuity check | Pro Required |
| Frigidaire E11 | Washer | Fill time exceeded (insufficient water intake) | Inlet solenoids 800 - 1,300 Ohms | Low |
| Frigidaire E13 | Washer | Water leak detected in basepan or pressure drift | Pressure sensor & hose seal check | Moderate |
| Frigidaire E21 | Washer | Water not pumping out fast enough (drain timeout) | Drain pump 12 - 22 Ohms | Low |
| Frigidaire E23 | Washer | Drain pump triac failure on main control board | Drain pump 12 - 22 Ohms (verify first) | Pro Required |
| Frigidaire E24 | Washer | Drain pump triac sensing circuit fault | Drain pump & harness continuity | Pro Required |
| Frigidaire E31 | Washer | Electronic pressure switch frequency fault | Pressure switch air tube clear | Moderate |
| Frigidaire E41 | Washer | Door open or door lock switch not sensing closed | Door lock switch 0 Ohms closed | Moderate |
| Frigidaire E42 | Washer | Door lock device failure (wax motor/solenoid) | Lock PTC/solenoid ~60 - 120 Ohms | Moderate |
| Frigidaire E43 | Washer | Main control board door-lock triac fault | Door lock coil verify before board swap | Pro Required |
| Frigidaire E56 | Washer | High motor current / bound drum bearing or spider | Drive motor windings ~5 - 15 Ohms | Pro Required |
| Frigidaire E57 | Washer | Inverter board over-current >15 Amps | Motor phase windings balanced ~5 - 15 Ohms | Pro Required |
| Frigidaire E59 | Washer | No tachometer signal from motor for 3 seconds | Tach coil ~115 - 170 Ohms | Moderate |
| Frigidaire E5A | Washer | High temperature on motor speed control heatsink | Inverter heatsink cooling check | Pro Required |
| Frigidaire E61 | Washer | Wash water heater heating too slowly | Heater element 20 - 35 Ohms | Moderate |
| Frigidaire E91 | Washer | Communication error between UI and main control | UI-to-main comms harness continuity | Pro Required |
| Frigidaire EF0 | Washer | Excess suds or blocked drain filter screen | Drain pump 12 - 22 Ohms | Low |
| Frigidaire E4A | Dryer | Dryer heating cycle time exceeded (>150 minutes) | IRC M1502 <= 35 ft rigid 4-in duct | Low |
| Frigidaire E64 | Dryer | Open heating element circuit | Heating coil 8 - 14 Ohms; high-limit 0 Ohms | Moderate |
| Frigidaire E68 | Dryer | Stuck control button (>30s) | Keypad continuity check | Moderate |
| Frigidaire EF1 | Dryer | Restricted exhaust vent airflow alert | 4-in rigid duct <= 35 ft | Low |
| Frigidaire i10 | Dishwasher | Low water fill detected in dishwasher | Inlet valve solenoid ~900 - 1,400 Ohms | Low |
| Frigidaire i30 | Dishwasher | Leak protection float triggered in bottom pan | Basepan float switch 0 Ohms tripped | Moderate |
| Frigidaire i40 | Dishwasher | Turbidity / pressure sensor calibration error | Pressure trap clean check | Moderate |
| Frigidaire i50 | Dishwasher | Drain or wash motor triac control fault | Pump coils ~15 - 25 Ohms | Pro Required |
| Frigidaire i60 | Dishwasher | Water heating timeout or open heater circuit | Heating element 10 - 30 Ohms | Moderate |
| Frigidaire uo | Dishwasher | Active vent open or jammed during dry cycle | Vent wax motor / switch continuity | Moderate |
| Frigidaire SY EF | Refrigerator | Evaporator fan circuit fault | 12V DC fan motor check | Moderate |
| Frigidaire SY CF | Refrigerator | Communication error between UI display and main board | Door harness continuity check | Pro Required |
| Frigidaire SY CE | Refrigerator | Control communication timeout | Harness continuity check | Pro Required |
| Frigidaire OP | Refrigerator | Open thermistor circuit (freezer or fresh food) | Thermistor ~10k Ohms at 77 deg F | Moderate |
| Frigidaire SH | Refrigerator | Shorted thermistor circuit | Thermistor ~10k Ohms at 77 deg F (not <500) | Moderate |
| Frigidaire H1 | Refrigerator | High-temperature alarm (>23 F freezer / >46 F fridge) | Door gasket & condenser fan check | Low |
| Frigidaire F10 | Oven / Range | Runaway oven temperature (>650 deg F) | RTD probe ~1,080 Ohms at 70 deg F | Pro Required |
| Frigidaire F11 | Oven / Range | Shorted keypad or touchpad membrane | Touchpad ribbon open check | Moderate |
| Frigidaire F13 | Oven / Range | EEPROM / internal EOC control board fault | 120V/240V supply verify | Pro Required |
| Frigidaire F30 | Oven / Range | Open oven temperature sensor probe | RTD probe 1,050 - 1,120 Ohms at 70 deg F | Moderate |
| Frigidaire F31 | Oven / Range | Shorted oven temperature sensor probe | RTD probe ~1,080 Ohms at 70 deg F | Moderate |
| Frigidaire F90 | Oven / Range | Maximum door unlock time exceeded on self-clean | Door lock motor ~1,500 - 2,500 Ohms | Moderate |
| Bosch E01 | Dishwasher | Power module relay fault (heating relay welded/open) | Main board relay & heater circuit | Pro Required |
| Bosch E02 | Dishwasher | Heating relay failure on main power module | Heat pump / heater ~10 - 25 Ohms | Pro Required |
| Bosch E04 | Dishwasher | Heater relay / diverter valve circuit fault | Heat pump & NTC check | Pro Required |
| Bosch E06 | Dishwasher | Door latch / Hall sensor state error | Door sensor switch continuity | Moderate |
| Bosch E09 | Dishwasher | Heating circuit open in circulation heat pump | Heat pump heater coil ~10 - 20 Ohms | Pro Required |
| Bosch E11 | Dishwasher | Sump NTC temperature sensor open or shorted | NTC thermistor ~10k Ohms at 77 deg F | Moderate |
| Bosch E14 | Dishwasher | Water inlet reed flowmeter not registering pulses | Flowmeter reed switch pulse check | Moderate |
| Bosch E18 | Dishwasher | Water supply fill level too low (inlet timeout) | Inlet AquaStop solenoid ~1,800 - 2,500 Ohms | Low |
| Bosch E19 | Dishwasher | Detergent dispenser / water-exchanger drain valve fault | Valve solenoid ~1,500 - 2,500 Ohms | Moderate |
| Bosch E22 | Dishwasher | Residual water left in sump / clogged micro-filter | 3-phase drain pump ~75 - 105 Ohms/pair | Low |
| Bosch E25 | Dishwasher | Drain pump impeller blocked or pump cover unlatched | 3-phase pump ~75 - 105 Ohms/pair | Low |
| Bosch E27 | Dishwasher | Low AC line voltage (<95V AC) detected | 120V AC supply voltage verify | Low |
| Bosch E16 | Washer | Door open when wash cycle started | Door lock switch 0 Ohms closed | Low |
| Bosch E17 | Washer | Water inlet timeout (>6 minutes) | Inlet solenoid 800 - 1,300 Ohms | Low |
| Bosch E18 | Washer | Drain pump timeout (>6 minutes) | Drain pump 10 - 25 Ohms | Low |
| Bosch E23 | Washer | AquaStop basepan float leak triggered | Base float microswitch continuity | Moderate |
| Bosch E29 | Washer | No water pressure / closed tap detected | Inlet valve solenoid check | Low |
| Bosch E36 | Washer | Door lock failed to lock/unlock cleanly | Lock solenoid ~60 - 120 Ohms | Moderate |
| Bosch E01 | Dryer | Fluff / lint filter & condenser airflow alert (heat pump) | No ohm fault (condenser clean needed) | Low |
| Bosch E06 | Dryer | Dryer door switch sensing error | Door switch 0 Ohms closed | Low |
| Bosch E10 | Dryer | Heat pump / heater NTC temperature sensor error | Thermistor ~10k Ohms at 77 deg F | Moderate |
| Bosch E50 | Dryer | Drive motor overload or control inverter fault | Motor windings ~5 - 15 Ohms | Pro Required |
| Speed Queen Er dO | Washer | Door open when Start pressed | Door switch 0 Ohms closed | Low |
| Speed Queen Er dU | Washer | Door unlock timeout at end of cycle | Lock solenoid & wax motor continuity | Moderate |
| Speed Queen Er FL | Washer | Fill time limit exceeded (10+ minutes) | Inlet solenoids 800 - 1,300 Ohms | Low |
| Speed Queen Er nF | Washer | No fill water flow sensed | Inlet solenoids & pressure hose check | Low |
| Speed Queen Er dr | Washer | Drain timeout (water still detected in outer tub) | Drain pump 10 - 22 Ohms | Low |
| Speed Queen Er ub | Washer | Out-of-balance condition aborted high-speed spin | Out-of-balance switch 0 Ohms closed | Low |
| Speed Queen Er SL | Washer | Suds lock or slow drain during spin ramp | Drain pump 10 - 22 Ohms | Low |
| Speed Queen PF | Washer | Power failure interrupted wash cycle | 120V AC supply verify | Low |
| Speed Queen Er Ht | Dryer | Heater / over-temperature limit fault | High-limit thermostat 0 Ohms closed | Moderate |
| Speed Queen Er do | Dryer | Dryer door open during start | Door switch 0 Ohms closed | Low |
| Speed Queen Er op | Dryer | Open outlet thermistor circuit | Thermistor ~10k Ohms at 77 deg F | Moderate |
| Speed Queen Er SH | Dryer | Shorted outlet thermistor circuit | Thermistor ~10k Ohms at 77 deg F | Moderate |
| Amana F1 E1 | Washer | Main control board internal fault | 120V AC supply check | Pro Required |
| Amana F5 E2 | Washer | Lid/door lock failed to engage | Lock coil 60 - 110 Ohms | Moderate |
| Amana F7 E1 | Washer | Basket speed tachometer fault | Shift actuator ~2k - 3.5k Ohms | Moderate |
| Amana F8 E1 | Washer | No fill / slow water fill timeout | Inlet valve coils 800 - 1,400 Ohms | Low |
| Amana F9 E1 | Washer | Long drain time (>6 minutes) | Drain pump 10 - 20 Ohms | Low |
| Amana PF | Dryer | Power outage interrupted drying | 240V breaker verify | Low |
| Amana F2 | Oven / Range | Oven cavity over-temperature fault | RTD sensor ~1,080 Ohms at 70 deg F | Pro Required |
| Amana F3 | Oven / Range | Oven RTD sensor open or shorted | RTD probe 1,050 - 1,120 Ohms at 70 deg F | Moderate |
| Kenmore F20 | Washer (110. Whirlpool OEM) | No water detected entering tub or flowmeter fault | Inlet coils 800 - 1,400 Ohms | Low |
| Kenmore F21 | Washer (110. Whirlpool OEM) | Long drain timeout (>8 minutes) | Drain pump 10 - 20 Ohms | Low |
| Kenmore F22 | Washer (110. Whirlpool OEM) | Door lock sensing failure | Lock solenoid 60 - 110 Ohms | Moderate |
| Kenmore F24 | Washer (110. Whirlpool OEM) | Water temperature sensor out of range | Thermistor ~10k - 50k Ohms | Moderate |
| Kenmore F28 | Washer (110. Whirlpool OEM) | Communication error between CCU and MCU | Comms harness continuity check | Pro Required |
| Kenmore F30 | Washer (110. Whirlpool OEM) | Dispenser motor cannot locate cam position | Dispenser motor ~1,200 - 2,000 Ohms | Moderate |
| Kenmore OE | Washer (796. LG OEM) | Drain timeout on LG-built Kenmore Elite washer | Drain pump 10 - 25 Ohms | Low |
| Kenmore UE | Washer (796. LG OEM) | Unbalanced drum load on LG-built Kenmore Elite | Hall tach & shock dampers check | Low |
| Kenmore LE | Washer (796. LG OEM) | Locked motor / Hall sensor on 796. Direct Drive | Stator ~5 - 15 Ohms/phase | Moderate |
| Kenmore Er IF | Refrigerator (795. LG OEM) | Ice fan speed fault on LG-built Kenmore 795. | 12V DC ice fan continuity | Moderate |
| Kenmore i20 | Dishwasher (587. Frigidaire OEM) | Drain timeout on Frigidaire-built Kenmore 587. | Drain pump 15 - 25 Ohms | Low |
| Kenmore E11 | Washer (417. Frigidaire OEM) | Fill timeout on Frigidaire-built Kenmore 417. | Inlet coils 800 - 1,300 Ohms | Low |
| Kenmore F10 | Oven / Range (790. Frigidaire OEM) | Runaway oven temperature on Frigidaire-built Kenmore 790. | RTD probe ~1,080 Ohms at 70 deg F | Pro Required |
| Kenmore F31 | Oven / Range (790. Frigidaire OEM) | Shorted oven RTD sensor on Kenmore 790. | RTD probe ~1,080 Ohms at 70 deg F | Moderate |
| LiftMaster / Chamberlain 1 Up / 2 Down | Garage Door Opener | Safety reversing sensors wire shorted or reversed polarity | Low-voltage 2-wire DC loop (~6V DC) | Low |
| LiftMaster / Chamberlain 1 Up / 3 Down | Garage Door Opener | Door control / wall button wire shorted | Wall console 2-wire DC loop | Low |
| LiftMaster / Chamberlain 1 Up / 4 Down | Garage Door Opener | Safety reversing sensors slightly misaligned (momentary beam break) | 6V DC modulated sensor pulse | Low |
| LiftMaster / Chamberlain 1 Up / 5 Down | Garage Door Opener | Motor overheated or RPM sensor failed to register motion | RPM optical sensor 5V pulse check | Moderate |
| LiftMaster / Chamberlain 2 Up / 1 Down | Garage Door Opener | Logic board memory or EEPROM fault | Logic board 120V AC / DC supply | Pro Required |
| LiftMaster / Chamberlain 2 Up / 2 Down | Garage Door Opener | Logic board internal relay or safety circuit fault | Logic board diagnostic check | Pro Required |
| LiftMaster / Chamberlain 2 Up / 3 Down | Garage Door Opener | Logic board motor relay stuck or travel limit lost | Travel module & logic board | Pro Required |
| LiftMaster / Chamberlain 3 Up / 2 Down | Garage Door Opener | Unable to set travel or position limits | Travel module encoder pulse | Moderate |
| LiftMaster / Chamberlain 3 Up / 3 Down | Garage Door Opener | Battery backup charging circuit fault (CA SB-969 units) | 12V SLA battery >= 12.4V resting | Low |
| LiftMaster / Chamberlain 4 Up / 2 Down | Garage Door Opener | Upward travel excessive force sensed (door heavy / broken spring) | Door balance check (door CLOSED) | Pro Required |
| LiftMaster / Chamberlain 4 Up / 3 Down | Garage Door Opener | Upward travel stopped by physical obstruction or binding track | Track roller & lock latch check | Low |
| LiftMaster / Chamberlain 4 Up / 5 Down | Garage Door Opener | Opener moved 6-8 inches and stopped (RPM or travel failure) | Travel module / capacitor check | Moderate |
| LiftMaster / Chamberlain 4 Up / 6 Down | Garage Door Opener | Safety sensor interrupted during downward travel (door reversed) | Photo-eyes <= 6 in off floor (16 CFR 1211) | Low |
| LiftMaster / Chamberlain 10 Work Light Flashes | Garage Door Opener | 16 CFR 1211 safety sensor tripped while closing | Photo-eye alignment & 2s reversal | Low |
| Genie 1 Red Blink | Garage Door Opener | Safe-T-Beam sensor obstruction or wire open | Safe-T-Beam low-voltage bus | Low |
| Genie 2 Red Blinks | Garage Door Opener | Safe-T-Beam wire shorted or reversed | Safe-T-Beam 2-wire continuity | Low |
| Genie 3 Red Blinks | Garage Door Opener | Safe-T-Beam hardware fault or sunlight overload | Safe-T-Beam voltage verify | Low |
| Genie 4 Red Blinks | Garage Door Opener | Safe-T-Beam source emitter failure | Safe-T-Beam bus | Low |
| Genie 5 Red Blinks | Garage Door Opener | Travel limit switch or opto-wheel fault | Opto-interrupter / limit check | Moderate |
| Genie 6 Red Blinks | Garage Door Opener | Excess motor force / broken door spring detected | Manual balance check (door CLOSED) | Pro Required |
| Genie Orange Battery LED | Garage Door Opener | Genie Integrated Battery Backup low or disconnected | 24V / 12V battery voltage test | Low |
| Schlage 3 Red Flashes | Smart Deadbolt | Incorrect User Code or Programming Code entered | 4x AA alkaline >= 5.6V resting | Low |
| Schlage 4 Red Flashes | Smart Deadbolt | Keypad temporarily locked out after 4 wrong codes | No fault coil | Low |
| Kwikset 3 Red Blinks | SmartCode Deadbolt | Low battery warning (bolt speed slowing) | 4x AA alkaline >= 5.6V resting | Low |
| Kwikset Alternating Red/Green | SmartCode Deadbolt | SmartCode programming error or failed user code delete | 4x AA alkaline >= 5.6V | Low |
| Whirlpool F0 E3 | Washer | Overload condition detected during wash or spin sensing | Drive motor windings ~3 - 10 Ohms | Low |
| Whirlpool F0 E7 | Washer | Load detected in drum during clean-washer cycle | No sensor coil | Low |
| Whirlpool F1 E3 | Washer | ACU mismatch or EEPROM configuration error | 120V AC supply verify | Pro Required |
| Whirlpool F2 E3 | Washer | UI and ACU software / button mismatch fault | UI ribbon continuity check | Pro Required |
| Whirlpool F3 E3 | Washer | Wash water temperature thermistor out of calibration | NTC thermistor ~10k - 50k Ohms | Moderate |
| Whirlpool F4 E1 | Washer | Wash water heater relay failure on ACU | Heater element 15 - 30 Ohms | Pro Required |
| Whirlpool F4 E2 | Washer | Water heating timeout (temp failed to rise) | Heater element 15 - 30 Ohms | Moderate |
| Whirlpool F8 E2 | Washer | Dispenser motor failed to reach target cam position | Dispenser actuator motor check | Moderate |
| Whirlpool F8 E5 | Washer | Hot and cold supply hoses reversed | Inlet thermistor temp check | Low |
| Whirlpool F9 E3 | Washer | Drain pump circuit open or control relay dropped | Drain pump 10 - 20 Ohms | Moderate |
| Whirlpool rL | Washer | Drum rotation / item detected during Clean Washer | No part fault | Low |
| GE E11 | Washer | Water fill timeout (slow or no water entry) | Inlet solenoids ~900 - 1,300 Ohms | Low |
| GE E21 | Washer | Main drain timeout (>6 minutes) | Drain pump 10 - 25 Ohms | Low |
| GE E26 | Washer | Water level pressure sensor out of range | Pressure sensor hose clear | Moderate |
| GE E33 | Washer | Drive motor thermal overload or locked rotor | Motor phase windings ~5 - 15 Ohms | Moderate |
| GE E45 | Washer | Inverter communication or tachometer signal fault | Tach / Hall sensor check | Pro Required |
| GE E1 | Dryer | Thermistor temperature sensor open circuit | Thermistor ~10k Ohms at 77 deg F | Moderate |
| GE E2 | Dryer | Thermistor temperature sensor shorted | Thermistor ~10k Ohms at 77 deg F | Moderate |
| GE E3 | Dryer | High-limit thermostat or exhaust over-temp trip | High-limit thermostat 0 Ohms closed | Moderate |
| GE dE | Refrigerator | Defrost cycle timeout (evaporator frost buildup) | Defrost heater 20 - 40 Ohms; bimetal 0 Ohms | Moderate |
| GE PF-FR | Refrigerator | Power failure warning on dispenser panel | 120V AC supply verify | Low |
| LG E1 | Washer | Water leak detected in basepan (FloodSafe / AquaStop) | Base float switch continuity | Moderate |
| LG E3 | Washer | Load sensing error on older LG top/front loaders | Hall sensor / tach check | Moderate |
| LG tE4 | Dryer | Dryer moisture or condenser thermistor fault | Thermistor ~10k Ohms at 77 deg F | Moderate |
| LG PF | Dryer | Power failure interrupted drying | 240V L1-L2 panel breaker verify | Low |
| LG CL | Dryer | Child Lock enabled on dryer display | No fault coil | Low |
| LG 1E | Refrigerator | Freezer / defrost thermistor failure | Thermistor ~10k - 30k Ohms | Moderate |
| LG CL | Dishwasher | Child Lock active on dishwasher panel | No fault coil | Low |
| LG F-7 | Oven / Range | Self-clean door lock switch fault | Door lock motor & microswitch check | Moderate |
| Samsung PF | Washer | Power failure during active wash cycle | 120V AC outlet verify | Low |
| Samsung SF | Washer | System / main PCB internal relay fault | 120V AC feed verify | Pro Required |
| Samsung 4E2 | Washer | Hot water supply connected to cold port (>122 F) | No part fault | Low |
| Samsung 8E / 8C | Washer | MEMS vibration sensor error on VRT drum | MEMS sensor 5V DC feed & harness | Moderate |
| Samsung AC / AC6 | Washer | Inverter to main PCB communication error | Serial comms harness continuity | Pro Required |
| Samsung bE2 | Washer | Stuck button on control panel (>30s) | Keypad continuity check | Moderate |
| Samsung PC | Dishwasher | Zone-wash diverter / distribution motor error | Zone motor & optical switch check | Moderate |
| Samsung C-31 | Oven / Range | Main PCB over-temperature alert (>185 F ambient) | Cooling blower & rear vent check | Pro Required |
| Frigidaire E10 | Washer | Water supply fill timeout (slow fill) | Inlet solenoids 800 - 1,300 Ohms | Low |
| Frigidaire E22 | Washer | Slow drain / partial sump blockage | Drain pump 12 - 22 Ohms | Low |
| Frigidaire E32 | Washer | Pressure sensor calibration drift during spin | Air trap tube clear | Moderate |
| Frigidaire E35 | Washer | Water overfill detected above safe limit | Inlet valve seat & pressure switch | Moderate |
| Frigidaire E44 | Washer | Door lock sensing circuit failure on board | Door lock switch 0 Ohms closed | Pro Required |
| Frigidaire E51 | Washer | Motor power triac shorted on speed control | Motor windings ~5 - 15 Ohms | Pro Required |
| Frigidaire E52 | Washer | No tachometer signal from motor | Tach coil ~115 - 170 Ohms | Moderate |
| Frigidaire E66 | Washer | Wash water heater relay fault | Heater coil 20 - 35 Ohms | Pro Required |
| Frigidaire E71 | Washer | Wash NTC thermistor open or shorted | Thermistor ~10k - 50k Ohms | Moderate |
| Frigidaire E61 | Dryer | Heater relay failure on dryer main control | Heater coil 8 - 14 Ohms | Pro Required |
| Frigidaire E91 | Dryer | UI to main control communication error | UI harness continuity | Pro Required |
| Frigidaire Er | Dishwasher | Membrane keypad / communication error | UI ribbon continuity check | Moderate |
| Frigidaire 5Y | Refrigerator | Display communication/SY code variant | Door hinge harness continuity | Pro Required |
| Frigidaire F14 | Oven / Range | Shorted keypad or touchpad cable fault | Keypad matrix open check | Moderate |
| Bosch E03 | Dishwasher | Auxiliary / water-softener or heat relay fault | Main board & valve check | Pro Required |
| Bosch E07 | Dishwasher | Zeolite drying fan / heater circuit fault | Zeolite blower motor check | Pro Required |
| Bosch E10 | Dishwasher | Heat pump scaling or heating element slow rise | Heat pump heater ~10 - 20 Ohms | Moderate |
| Bosch E12 | Dishwasher | Calcified heat pump / mineral scale buildup | Heat pump heater ~10 - 20 Ohms | Moderate |
| Bosch E16 | Dishwasher | Water inlet valve failed to close (continuous fill) | Inlet valve solenoid check | Moderate |
| Bosch E20 | Dishwasher | Circulation pump winding resistance out of spec | 3-phase wash motor ~30 - 60 Ohms/pair | Pro Required |
| Bosch E21 | Dishwasher | Circulation pump rotor mechanically jammed | 3-phase motor ~30 - 60 Ohms/pair | Moderate |
| Bosch E23 | Dishwasher | Drain pump electrical open or phase imbalance | 3-phase drain pump ~75 - 105 Ohms/pair | Moderate |
| Maytag E1 | Washer | Inlet / pressure sensor error on Maxima/Neptune | Pressure switch air tube clear | Moderate |
| Maytag E2 | Washer | Drain pump timeout on legacy Maytag washer | Drain pump 10 - 22 Ohms | Low |
| Maytag HE | Dryer | Heating / thermal cutoff fault on Bravos/Maxima | Heater 8 - 14 Ohms; fuse 0 - 1.5 Ohms | Moderate |
| Maytag F3 E0 | Dishwasher | OWI turbidity / water temp sensor fault | Thermistor ~45k - 55k Ohms | Moderate |
| Maytag F1 E1 | Dishwasher | Main dishwasher control board relay fault | 120V AC feed verify | Pro Required |
| KitchenAid Er | Refrigerator | Communication or sensor fault on KitchenAid display | Thermistor & hinge harness check | Moderate |
| KitchenAid CF | Refrigerator | Cooling / condenser fan airflow alert | 12V DC condenser fan check | Moderate |
| Amana F2 E1 | Washer | Stuck key on washer control console | UI ribbon continuity check | Moderate |
| Amana F3 E1 | Washer | Water level pressure sensor out of range | Pressure hose clear | Moderate |
| Amana Sd | Washer | Excessive suds detected during wash | No part fault | Low |
| Amana AF | Dryer | Airflow restriction warning in exhaust vent | IRC M1502 <= 35 ft rigid duct | Low |
FAQ
Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.
How do multimeter Ohm specs isolate faulty appliance components?
With AC power unplugged and capacitors discharged, technicians compare terminal resistance against OEM windows: 10-25 Ohms for drain pumps, 800-1,400 Ohms for inlet valves, and 0-1.5 Ohms for thermal fuses.
What does a 0-1.5 Ohm reading mean on a dryer thermal fuse?
A reading between 0 and 1.5 Ohms indicates intact closed continuity; an infinite (OL) reading confirms a blown thermal cutoff caused by restricted rigid-metal dryer venting.
Why must garage door opener error codes avoid tension spring adjustments?
Opener flash codes often follow mechanical binding; if a wound torsion spring above the door has a gap, keep the door closed and call a trained technician.
How can homeowners verify if a fault code requires a licensed pro?
CodeBench separates low-hazard cleaning and continuity checks from Pro Required tiers involving 240V heating circuits, gas ignition manifolds, R-600a cooling lines, and torsion springs.
Can unplugging an appliance permanently fix an OEM error code?
A 60-second breaker reset clears transient logic lockups only; failing pumps, open thermal fuses, or misaligned 16 CFR 1211 photo-eyes will re-trigger the fault.
What thermistor resistance should an oven RTD sensor show at room temperature?
Standard residential oven RTD temperature probes read approximately 1,050 to 1,120 Ohms at 70 F, whereas refrigerator NTC thermistors typically test near 10,000 Ohms at 77 F.
When is repairing an error code NOT economical out of warranty?
Once an appliance exceeds half its NAHB median lifespan (13 yrs fridge/dryer, 10 yrs washer, 9 yrs dishwasher), board or motor quotes above 50% replacement cost favor upgrading.
Who should NOT use CodeBench error code tolerances for commercial units?
Resistance ranges and NAHB age guidelines apply exclusively to 120V/240V residential out-of-warranty appliances, residential openers, and residential smart deadbolts.
Related guides
Sources
- OEM Service & Owner Manuals (GE, Whirlpool, LG, Samsung, Frigidaire, Bosch, Speed Queen, LiftMaster, Chamberlain, Genie, Wayne Dalton, Schlage, Kwikset) — Respective Equipment Manufacturers, 2020-2026 OEM Technical Publications (retrieved 2026-11-23)