Maytag Error Codes & Multimeter Reference (27 Codes)
Look up all 27 verified Maytag fault, blink, and warning codes across Dishwasher, Dryer, Oven / Range, Washer. Each code entry details plain-English meanings, isolated multimeter Ohm ranges, common failing components, typical U.S. out-of-warranty repair cost bands, and safe DIY vs licensed technician limits. All figures come directly from EPA ENERGY STAR, EIA utility records, CPSC and NHTSA safety recalls, federal safety standards, Bureau of Labor Statistics wages, and public state licensing boards for U.S. out-of-warranty home repairs.
- Maytag Error Codes
- 27
- Systems Covered
- Dishwasher, Dryer, Oven / Range, Washer
- Pro-Escalation Codes
- 3 of 27
- Catalog Reference
- 414 total US codes
Which manufacturer error code directories are indexed?
Jump straight to any of the 15 major residential appliance, garage door opener, and smart deadbolt brands below for complete fault definitions and component repair cost bands.
-
Amana 12 codes
Dryer, Oven / Range, Washer -
Bosch 32 codes
Dishwasher, Dryer, Washer -
Frigidaire 53 codes
Dishwasher, Dryer, Oven / Range, Refrigerator, Washer -
GE 41 codes
Dishwasher, Dryer, Oven / Range, Refrigerator, Washer -
Genie 8 codes
Garage Door Opener -
Kenmore 14 codes
Dishwasher (587. Frigidaire OEM), Oven / Range (790. Frigidaire OEM), Refrigerator (795. LG OEM), Washer (110. Whirlpool OEM), Washer (417. Frigidaire OEM) -
KitchenAid 20 codes
Dishwasher, Oven / Range, Refrigerator -
Kwikset 3 codes
SmartCode Deadbolt -
LG 56 codes
Dishwasher, Dryer, Oven / Range, Refrigerator, Washer -
LiftMaster / Chamberlain 16 codes
Garage Door Opener -
Maytag 27 codes
Dishwasher, Dryer, Oven / Range, Washer -
Samsung 57 codes
Dishwasher, Dryer, Oven / Range, Refrigerator, Washer -
Schlage 3 codes
Smart Deadbolt -
Speed Queen 13 codes
Dryer, Washer -
Whirlpool 59 codes
Dishwasher, Dryer, Oven / Range, Refrigerator, Washer
How do your multimeter Ohm readings compare against OEM tolerances?
Disconnect AC power and discharge high-voltage capacitors first, then select a component to test drain pumps (10-25 Ohms), inlet valves, thermal fuses, or NTC sensors.
Which appliance fault tiers are safe for DIY vs pro escalation?
CodeBench separates accessible filter and continuity checks from hazardous sealed-refrigerant lines, 240V relays, gas manifolds, and preloaded garage door torsion springs.
- Low Hazard
- Coin trap cleaning, inlet screens, sensor alignment, alkaline battery swaps.
- Moderate Hazard
- Unplugged thermistor / pump ohm tests, AquaStop sump pan checks.
- Pro Required
- 240V oven relays, gas valves, R-600a sealed cooling, garage torsion springs.
Which verified OEM error and blink codes are indexed?
27 codesFilter 27 documented error, blink, and keypad fault codes across major residential washer, dryer, dishwasher, opener, and lock platforms with multimeter specs.
| Brand & Code | System | Definition | Ohm / Test Spec | Hazard |
|---|---|---|---|---|
| Maytag F0 E1 | Washer | Load detected in drum during clean-washer cycle | No sensor coil (basket must be empty) | Low |
| Maytag F5 E1 | Washer | Lid/door switch fails to register closed position | 0 Ohms closed across lid switch contacts | Low |
| Maytag F5 E2 | Washer | Door lock solenoid timeout on Maxima/Bravos | Lock coil 60 - 110 Ohms | Moderate |
| Maytag F7 E1 | Washer | Basket speed sensor / tach fault | Tachometer & shift actuator ~2k Ohms | Moderate |
| Maytag F8 E1 | Washer | Long fill timeout or cold/hot supply blocked | Water inlet coils 800 - 1,400 Ohms | Low |
| Maytag F9 E1 | Washer | Drain timeout exceeding 6 minutes | Drain pump motor 10 - 20 Ohms | Low |
| Maytag oL | Washer | Overloaded basket / motor current limit tripped | Drive motor windings ~3 - 10 Ohms | Low |
| Maytag uL | Washer | Unbalanced load during spin extraction | Suspension rod & leveling check | Low |
| Maytag dL | Washer | Door lock failed to engage within 3 tries | Lock solenoid 60 - 110 Ohms | Moderate |
| Maytag nd | Washer | No drain: tub pressure remained high after drain phase | Drain pump 10 - 20 Ohms | Low |
| Maytag nF | Washer | No fill: insufficient water entered within 8 minutes | Inlet valve solenoids 800 - 1,400 Ohms | Low |
| Maytag LO | Washer | Door failed to unlock after cycle stop | Door lock PTC & solenoid check | Moderate |
| Maytag Sd | Washer | Excessive suds preventing drain/spin transition | No part fault (excess detergent) | Low |
| Maytag PF | Washer | Power failure mid-cycle | 120V AC GFCI / breaker verify | Low |
| Maytag AF | Dryer | Restricted airflow detected on Bravos/Maxima dryer | IRC M1502 <= 35 ft rigid 4-in duct | Low |
| Maytag F1 | Dryer | Dryer control board heater relay fault | Main board relay test | Pro Required |
| Maytag F3 E1 | Dryer | Exhaust thermistor open circuit | Thermistor ~10k Ohms at 77 deg F | Moderate |
| Maytag F4 E3 | Dryer | Dryer thermal cutoff / restricted vent overheat | Thermal fuse 0 - 1.5 Ohms | Moderate |
| Maytag F8 E4 | Dishwasher | Overfill float / basepan water sensor tripped | Float switch 0 Ohms closed | Moderate |
| Maytag F9 E1 | Dishwasher | Long drain fault in dishwasher sump | Drain pump 15 - 30 Ohms | Low |
| Maytag F2 | Oven / Range | Oven cavity over-temperature fault | RTD probe ~1,080 Ohms at 70 deg F | Pro Required |
| Maytag F3 E0 | Oven / Range | Oven RTD sensor open or shorted | RTD probe 1,050 - 1,120 Ohms at 70 deg F | Moderate |
| Maytag E1 | Washer | Inlet / pressure sensor error on Maxima/Neptune | Pressure switch air tube clear | Moderate |
| Maytag E2 | Washer | Drain pump timeout on legacy Maytag washer | Drain pump 10 - 22 Ohms | Low |
| Maytag HE | Dryer | Heating / thermal cutoff fault on Bravos/Maxima | Heater 8 - 14 Ohms; fuse 0 - 1.5 Ohms | Moderate |
| Maytag F3 E0 | Dishwasher | OWI turbidity / water temp sensor fault | Thermistor ~45k - 55k Ohms | Moderate |
| Maytag F1 E1 | Dishwasher | Main dishwasher control board relay fault | 120V AC feed verify | Pro Required |
FAQ
Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.
How do multimeter Ohm specs isolate faulty appliance components?
With AC power unplugged and capacitors discharged, technicians compare terminal resistance against OEM windows: 10-25 Ohms for drain pumps, 800-1,400 Ohms for inlet valves, and 0-1.5 Ohms for thermal fuses.
What does a 0-1.5 Ohm reading mean on a dryer thermal fuse?
A reading between 0 and 1.5 Ohms indicates intact closed continuity; an infinite (OL) reading confirms a blown thermal cutoff caused by restricted rigid-metal dryer venting.
Why must garage door opener error codes avoid tension spring adjustments?
Opener flash codes often follow mechanical binding; if a wound torsion spring above the door has a gap, keep the door closed and call a trained technician.
How can homeowners verify if a fault code requires a licensed pro?
CodeBench separates low-hazard cleaning and continuity checks from Pro Required tiers involving 240V heating circuits, gas ignition manifolds, R-600a cooling lines, and torsion springs.
Can unplugging an appliance permanently fix an OEM error code?
A 60-second breaker reset clears transient logic lockups only; failing pumps, open thermal fuses, or misaligned 16 CFR 1211 photo-eyes will re-trigger the fault.
What thermistor resistance should an oven RTD sensor show at room temperature?
Standard residential oven RTD temperature probes read approximately 1,050 to 1,120 Ohms at 70 F, whereas refrigerator NTC thermistors typically test near 10,000 Ohms at 77 F.
When is repairing an error code NOT economical out of warranty?
Once an appliance exceeds half its NAHB median lifespan (13 yrs fridge/dryer, 10 yrs washer, 9 yrs dishwasher), board or motor quotes above 50% replacement cost favor upgrading.
Who should NOT use CodeBench error code tolerances for commercial units?
Resistance ranges and NAHB age guidelines apply exclusively to 120V/240V residential out-of-warranty appliances, residential openers, and residential smart deadbolts.
Related guides
Sources
- OEM Service & Owner Manuals (GE, Whirlpool, LG, Samsung, Frigidaire, Bosch, Speed Queen, LiftMaster, Chamberlain, Genie, Wayne Dalton, Schlage, Kwikset) — Respective Equipment Manufacturers, 2020-2026 OEM Technical Publications (retrieved 2026-11-23)
- 16 CFR Part 1211 - Safety Standard for Automatic Residential Garage Door Operators — U.S. Consumer Product Safety Commission / eCFR, 2026-11-18 (retrieved 2026-11-23)
- International Residential Code (IRC) Section M1502.4.5 - Dryer Exhaust Ducts — International Code Council (ICC), IRC 2021 / 2024 (retrieved 2026-11-23)