Bosch Error Codes & Multimeter Reference (32 Codes)
Look up all 32 verified Bosch fault, blink, and warning codes across Dishwasher, Dryer, Washer. Each code entry details plain-English meanings, isolated multimeter Ohm ranges, common failing components, typical U.S. out-of-warranty repair cost bands, and safe DIY vs licensed technician limits. All figures come directly from EPA ENERGY STAR, EIA utility records, CPSC and NHTSA safety recalls, federal safety standards, Bureau of Labor Statistics wages, and public state licensing boards for U.S. out-of-warranty home repairs.
- Bosch Error Codes
- 32
- Systems Covered
- Dishwasher, Dryer, Washer
- Pro-Escalation Codes
- 8 of 32
- Catalog Reference
- 414 total US codes
Which manufacturer error code directories are indexed?
Jump straight to any of the 15 major residential appliance, garage door opener, and smart deadbolt brands below for complete fault definitions and component repair cost bands.
-
Amana 12 codes
Dryer, Oven / Range, Washer -
Bosch 32 codes
Dishwasher, Dryer, Washer -
Frigidaire 53 codes
Dishwasher, Dryer, Oven / Range, Refrigerator, Washer -
GE 41 codes
Dishwasher, Dryer, Oven / Range, Refrigerator, Washer -
Genie 8 codes
Garage Door Opener -
Kenmore 14 codes
Dishwasher (587. Frigidaire OEM), Oven / Range (790. Frigidaire OEM), Refrigerator (795. LG OEM), Washer (110. Whirlpool OEM), Washer (417. Frigidaire OEM) -
KitchenAid 20 codes
Dishwasher, Oven / Range, Refrigerator -
Kwikset 3 codes
SmartCode Deadbolt -
LG 56 codes
Dishwasher, Dryer, Oven / Range, Refrigerator, Washer -
LiftMaster / Chamberlain 16 codes
Garage Door Opener -
Maytag 27 codes
Dishwasher, Dryer, Oven / Range, Washer -
Samsung 57 codes
Dishwasher, Dryer, Oven / Range, Refrigerator, Washer -
Schlage 3 codes
Smart Deadbolt -
Speed Queen 13 codes
Dryer, Washer -
Whirlpool 59 codes
Dishwasher, Dryer, Oven / Range, Refrigerator, Washer
How do your multimeter Ohm readings compare against OEM tolerances?
Disconnect AC power and discharge high-voltage capacitors first, then select a component to test drain pumps (10-25 Ohms), inlet valves, thermal fuses, or NTC sensors.
Which appliance fault tiers are safe for DIY vs pro escalation?
CodeBench separates accessible filter and continuity checks from hazardous sealed-refrigerant lines, 240V relays, gas manifolds, and preloaded garage door torsion springs.
- Low Hazard
- Coin trap cleaning, inlet screens, sensor alignment, alkaline battery swaps.
- Moderate Hazard
- Unplugged thermistor / pump ohm tests, AquaStop sump pan checks.
- Pro Required
- 240V oven relays, gas valves, R-600a sealed cooling, garage torsion springs.
Which verified OEM error and blink codes are indexed?
32 codesFilter 32 documented error, blink, and keypad fault codes across major residential washer, dryer, dishwasher, opener, and lock platforms with multimeter specs.
| Brand & Code | System | Definition | Ohm / Test Spec | Hazard |
|---|---|---|---|---|
| Bosch E15 | Dishwasher | AquaStop basepan float switch triggered by internal water leak | Base float microswitch open circuit when dry | Moderate |
| Bosch E24 | Dishwasher | Drain hose blocked, kinked, or drain pump cover unlatched | 3-phase drain pump balanced windings ~75 - 105 Ohms per pair | Low |
| Bosch E01 | Dishwasher | Power module relay fault (heating relay welded/open) | Main board relay & heater circuit | Pro Required |
| Bosch E02 | Dishwasher | Heating relay failure on main power module | Heat pump / heater ~10 - 25 Ohms | Pro Required |
| Bosch E04 | Dishwasher | Heater relay / diverter valve circuit fault | Heat pump & NTC check | Pro Required |
| Bosch E06 | Dishwasher | Door latch / Hall sensor state error | Door sensor switch continuity | Moderate |
| Bosch E09 | Dishwasher | Heating circuit open in circulation heat pump | Heat pump heater coil ~10 - 20 Ohms | Pro Required |
| Bosch E11 | Dishwasher | Sump NTC temperature sensor open or shorted | NTC thermistor ~10k Ohms at 77 deg F | Moderate |
| Bosch E14 | Dishwasher | Water inlet reed flowmeter not registering pulses | Flowmeter reed switch pulse check | Moderate |
| Bosch E18 | Dishwasher | Water supply fill level too low (inlet timeout) | Inlet AquaStop solenoid ~1,800 - 2,500 Ohms | Low |
| Bosch E19 | Dishwasher | Detergent dispenser / water-exchanger drain valve fault | Valve solenoid ~1,500 - 2,500 Ohms | Moderate |
| Bosch E22 | Dishwasher | Residual water left in sump / clogged micro-filter | 3-phase drain pump ~75 - 105 Ohms/pair | Low |
| Bosch E25 | Dishwasher | Drain pump impeller blocked or pump cover unlatched | 3-phase pump ~75 - 105 Ohms/pair | Low |
| Bosch E27 | Dishwasher | Low AC line voltage (<95V AC) detected | 120V AC supply voltage verify | Low |
| Bosch E16 | Washer | Door open when wash cycle started | Door lock switch 0 Ohms closed | Low |
| Bosch E17 | Washer | Water inlet timeout (>6 minutes) | Inlet solenoid 800 - 1,300 Ohms | Low |
| Bosch E18 | Washer | Drain pump timeout (>6 minutes) | Drain pump 10 - 25 Ohms | Low |
| Bosch E23 | Washer | AquaStop basepan float leak triggered | Base float microswitch continuity | Moderate |
| Bosch E29 | Washer | No water pressure / closed tap detected | Inlet valve solenoid check | Low |
| Bosch E36 | Washer | Door lock failed to lock/unlock cleanly | Lock solenoid ~60 - 120 Ohms | Moderate |
| Bosch E01 | Dryer | Fluff / lint filter & condenser airflow alert (heat pump) | No ohm fault (condenser clean needed) | Low |
| Bosch E06 | Dryer | Dryer door switch sensing error | Door switch 0 Ohms closed | Low |
| Bosch E10 | Dryer | Heat pump / heater NTC temperature sensor error | Thermistor ~10k Ohms at 77 deg F | Moderate |
| Bosch E50 | Dryer | Drive motor overload or control inverter fault | Motor windings ~5 - 15 Ohms | Pro Required |
| Bosch E03 | Dishwasher | Auxiliary / water-softener or heat relay fault | Main board & valve check | Pro Required |
| Bosch E07 | Dishwasher | Zeolite drying fan / heater circuit fault | Zeolite blower motor check | Pro Required |
| Bosch E10 | Dishwasher | Heat pump scaling or heating element slow rise | Heat pump heater ~10 - 20 Ohms | Moderate |
| Bosch E12 | Dishwasher | Calcified heat pump / mineral scale buildup | Heat pump heater ~10 - 20 Ohms | Moderate |
| Bosch E16 | Dishwasher | Water inlet valve failed to close (continuous fill) | Inlet valve solenoid check | Moderate |
| Bosch E20 | Dishwasher | Circulation pump winding resistance out of spec | 3-phase wash motor ~30 - 60 Ohms/pair | Pro Required |
| Bosch E21 | Dishwasher | Circulation pump rotor mechanically jammed | 3-phase motor ~30 - 60 Ohms/pair | Moderate |
| Bosch E23 | Dishwasher | Drain pump electrical open or phase imbalance | 3-phase drain pump ~75 - 105 Ohms/pair | Moderate |
FAQ
Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.
How do multimeter Ohm specs isolate faulty appliance components?
With AC power unplugged and capacitors discharged, technicians compare terminal resistance against OEM windows: 10-25 Ohms for drain pumps, 800-1,400 Ohms for inlet valves, and 0-1.5 Ohms for thermal fuses.
What does a 0-1.5 Ohm reading mean on a dryer thermal fuse?
A reading between 0 and 1.5 Ohms indicates intact closed continuity; an infinite (OL) reading confirms a blown thermal cutoff caused by restricted rigid-metal dryer venting.
Why must garage door opener error codes avoid tension spring adjustments?
Opener flash codes often follow mechanical binding; if a wound torsion spring above the door has a gap, keep the door closed and call a trained technician.
How can homeowners verify if a fault code requires a licensed pro?
CodeBench separates low-hazard cleaning and continuity checks from Pro Required tiers involving 240V heating circuits, gas ignition manifolds, R-600a cooling lines, and torsion springs.
Can unplugging an appliance permanently fix an OEM error code?
A 60-second breaker reset clears transient logic lockups only; failing pumps, open thermal fuses, or misaligned 16 CFR 1211 photo-eyes will re-trigger the fault.
What thermistor resistance should an oven RTD sensor show at room temperature?
Standard residential oven RTD temperature probes read approximately 1,050 to 1,120 Ohms at 70 F, whereas refrigerator NTC thermistors typically test near 10,000 Ohms at 77 F.
When is repairing an error code NOT economical out of warranty?
Once an appliance exceeds half its NAHB median lifespan (13 yrs fridge/dryer, 10 yrs washer, 9 yrs dishwasher), board or motor quotes above 50% replacement cost favor upgrading.
Who should NOT use CodeBench error code tolerances for commercial units?
Resistance ranges and NAHB age guidelines apply exclusively to 120V/240V residential out-of-warranty appliances, residential openers, and residential smart deadbolts.
Related guides
Sources
- OEM Service & Owner Manuals (GE, Whirlpool, LG, Samsung, Frigidaire, Bosch, Speed Queen, LiftMaster, Chamberlain, Genie, Wayne Dalton, Schlage, Kwikset) — Respective Equipment Manufacturers, 2020-2026 OEM Technical Publications (retrieved 2026-11-23)
- 16 CFR Part 1211 - Safety Standard for Automatic Residential Garage Door Operators — U.S. Consumer Product Safety Commission / eCFR, 2026-11-18 (retrieved 2026-11-23)
- International Residential Code (IRC) Section M1502.4.5 - Dryer Exhaust Ducts — International Code Council (ICC), IRC 2021 / 2024 (retrieved 2026-11-23)