Skip to main content
Bosch Fault Chart

Bosch Error Codes & Multimeter Reference (32 Codes)

Look up all 32 verified Bosch fault, blink, and warning codes across Dishwasher, Dryer, Washer. Each code entry details plain-English meanings, isolated multimeter Ohm ranges, common failing components, typical U.S. out-of-warranty repair cost bands, and safe DIY vs licensed technician limits. All figures come directly from EPA ENERGY STAR, EIA utility records, CPSC and NHTSA safety recalls, federal safety standards, Bureau of Labor Statistics wages, and public state licensing boards for U.S. out-of-warranty home repairs.

Bosch Error Codes
32
Systems Covered
Dishwasher, Dryer, Washer
Pro-Escalation Codes
8 of 32
Catalog Reference
414 total US codes

Which manufacturer error code directories are indexed?

Jump straight to any of the 15 major residential appliance, garage door opener, and smart deadbolt brands below for complete fault definitions and component repair cost bands.

How do your multimeter Ohm readings compare against OEM tolerances?

Disconnect AC power and discharge high-voltage capacitors first, then select a component to test drain pumps (10-25 Ohms), inlet valves, thermal fuses, or NTC sensors.

  • LG / Samsung Drain Pump (10 - 25 Ohms)
  • Water Inlet Solenoid (800 - 1,400 Ohms)
  • Dryer Thermal Fuse (0 - 1.5 Ohms)
  • Dryer Heating Element (8 - 14 Ohms)
  • Oven RTD Sensor @ 70 F (1,050 - 1,120 Ohms)
  • NTC Thermistor @ 77 F (9,000 - 11,000 Ohms)

Which appliance fault tiers are safe for DIY vs pro escalation?

CodeBench separates accessible filter and continuity checks from hazardous sealed-refrigerant lines, 240V relays, gas manifolds, and preloaded garage door torsion springs.

Low Hazard
Coin trap cleaning, inlet screens, sensor alignment, alkaline battery swaps.
Moderate Hazard
Unplugged thermistor / pump ohm tests, AquaStop sump pan checks.
Pro Required
240V oven relays, gas valves, R-600a sealed cooling, garage torsion springs.

Which verified OEM error and blink codes are indexed?

32 codes

Filter 32 documented error, blink, and keypad fault codes across major residential washer, dryer, dishwasher, opener, and lock platforms with multimeter specs.

Verified OEM fault and blink codes with multimeter Ohm test specifications and hazard classification
Brand & CodeSystemDefinitionOhm / Test SpecHazard
Bosch E15 Dishwasher AquaStop basepan float switch triggered by internal water leak Base float microswitch open circuit when dry Moderate
Bosch E24 Dishwasher Drain hose blocked, kinked, or drain pump cover unlatched 3-phase drain pump balanced windings ~75 - 105 Ohms per pair Low
Bosch E01 Dishwasher Power module relay fault (heating relay welded/open) Main board relay & heater circuit Pro Required
Bosch E02 Dishwasher Heating relay failure on main power module Heat pump / heater ~10 - 25 Ohms Pro Required
Bosch E04 Dishwasher Heater relay / diverter valve circuit fault Heat pump & NTC check Pro Required
Bosch E06 Dishwasher Door latch / Hall sensor state error Door sensor switch continuity Moderate
Bosch E09 Dishwasher Heating circuit open in circulation heat pump Heat pump heater coil ~10 - 20 Ohms Pro Required
Bosch E11 Dishwasher Sump NTC temperature sensor open or shorted NTC thermistor ~10k Ohms at 77 deg F Moderate
Bosch E14 Dishwasher Water inlet reed flowmeter not registering pulses Flowmeter reed switch pulse check Moderate
Bosch E18 Dishwasher Water supply fill level too low (inlet timeout) Inlet AquaStop solenoid ~1,800 - 2,500 Ohms Low
Bosch E19 Dishwasher Detergent dispenser / water-exchanger drain valve fault Valve solenoid ~1,500 - 2,500 Ohms Moderate
Bosch E22 Dishwasher Residual water left in sump / clogged micro-filter 3-phase drain pump ~75 - 105 Ohms/pair Low
Bosch E25 Dishwasher Drain pump impeller blocked or pump cover unlatched 3-phase pump ~75 - 105 Ohms/pair Low
Bosch E27 Dishwasher Low AC line voltage (<95V AC) detected 120V AC supply voltage verify Low
Bosch E16 Washer Door open when wash cycle started Door lock switch 0 Ohms closed Low
Bosch E17 Washer Water inlet timeout (>6 minutes) Inlet solenoid 800 - 1,300 Ohms Low
Bosch E18 Washer Drain pump timeout (>6 minutes) Drain pump 10 - 25 Ohms Low
Bosch E23 Washer AquaStop basepan float leak triggered Base float microswitch continuity Moderate
Bosch E29 Washer No water pressure / closed tap detected Inlet valve solenoid check Low
Bosch E36 Washer Door lock failed to lock/unlock cleanly Lock solenoid ~60 - 120 Ohms Moderate
Bosch E01 Dryer Fluff / lint filter & condenser airflow alert (heat pump) No ohm fault (condenser clean needed) Low
Bosch E06 Dryer Dryer door switch sensing error Door switch 0 Ohms closed Low
Bosch E10 Dryer Heat pump / heater NTC temperature sensor error Thermistor ~10k Ohms at 77 deg F Moderate
Bosch E50 Dryer Drive motor overload or control inverter fault Motor windings ~5 - 15 Ohms Pro Required
Bosch E03 Dishwasher Auxiliary / water-softener or heat relay fault Main board & valve check Pro Required
Bosch E07 Dishwasher Zeolite drying fan / heater circuit fault Zeolite blower motor check Pro Required
Bosch E10 Dishwasher Heat pump scaling or heating element slow rise Heat pump heater ~10 - 20 Ohms Moderate
Bosch E12 Dishwasher Calcified heat pump / mineral scale buildup Heat pump heater ~10 - 20 Ohms Moderate
Bosch E16 Dishwasher Water inlet valve failed to close (continuous fill) Inlet valve solenoid check Moderate
Bosch E20 Dishwasher Circulation pump winding resistance out of spec 3-phase wash motor ~30 - 60 Ohms/pair Pro Required
Bosch E21 Dishwasher Circulation pump rotor mechanically jammed 3-phase motor ~30 - 60 Ohms/pair Moderate
Bosch E23 Dishwasher Drain pump electrical open or phase imbalance 3-phase drain pump ~75 - 105 Ohms/pair Moderate

FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

How do multimeter Ohm specs isolate faulty appliance components?

With AC power unplugged and capacitors discharged, technicians compare terminal resistance against OEM windows: 10-25 Ohms for drain pumps, 800-1,400 Ohms for inlet valves, and 0-1.5 Ohms for thermal fuses.

What does a 0-1.5 Ohm reading mean on a dryer thermal fuse?

A reading between 0 and 1.5 Ohms indicates intact closed continuity; an infinite (OL) reading confirms a blown thermal cutoff caused by restricted rigid-metal dryer venting.

Why must garage door opener error codes avoid tension spring adjustments?

Opener flash codes often follow mechanical binding; if a wound torsion spring above the door has a gap, keep the door closed and call a trained technician.

How can homeowners verify if a fault code requires a licensed pro?

CodeBench separates low-hazard cleaning and continuity checks from Pro Required tiers involving 240V heating circuits, gas ignition manifolds, R-600a cooling lines, and torsion springs.

Can unplugging an appliance permanently fix an OEM error code?

A 60-second breaker reset clears transient logic lockups only; failing pumps, open thermal fuses, or misaligned 16 CFR 1211 photo-eyes will re-trigger the fault.

What thermistor resistance should an oven RTD sensor show at room temperature?

Standard residential oven RTD temperature probes read approximately 1,050 to 1,120 Ohms at 70 F, whereas refrigerator NTC thermistors typically test near 10,000 Ohms at 77 F.

When is repairing an error code NOT economical out of warranty?

Once an appliance exceeds half its NAHB median lifespan (13 yrs fridge/dryer, 10 yrs washer, 9 yrs dishwasher), board or motor quotes above 50% replacement cost favor upgrading.

Who should NOT use CodeBench error code tolerances for commercial units?

Resistance ranges and NAHB age guidelines apply exclusively to 120V/240V residential out-of-warranty appliances, residential openers, and residential smart deadbolts.

Related guides

Sources

  1. OEM Service & Owner Manuals (GE, Whirlpool, LG, Samsung, Frigidaire, Bosch, Speed Queen, LiftMaster, Chamberlain, Genie, Wayne Dalton, Schlage, Kwikset) — Respective Equipment Manufacturers, 2020-2026 OEM Technical Publications (retrieved 2026-11-23)
  2. 16 CFR Part 1211 - Safety Standard for Automatic Residential Garage Door Operators — U.S. Consumer Product Safety Commission / eCFR, 2026-11-18 (retrieved 2026-11-23)
  3. International Residential Code (IRC) Section M1502.4.5 - Dryer Exhaust Ducts — International Code Council (ICC), IRC 2021 / 2024 (retrieved 2026-11-23)