Linari FOR-52 Ceiling Fan Specs
Specified at 52.0 in span and Airflow Efficiency 179 CFM/W, Linari FOR-52 scores higher efficiency than 29.4% of 1,241 ceiling fans in the U.S. ENERGY STAR directory. Shared internal engineering unites 2 finish SKUs including FOR-52, FOR-52-**** within a standard residential footprint. Evaluated over a 15-year NAHB benchmark service window, operating power equals rated service expectations across a 15-year NAHB lifespan with ENERGY STAR certified margin under DOE 10 CFR 430.
- Rated Energy
- Ceiling Fans
- EIA Annual Cost
- Not listed
- Category Rank
- #876 of 1,241
- Capacity
- 52.0 in span
- NAHB Lifespan
- 15 years
What are the official specs and computed benchmarks for Linari FOR-52?
Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.
| Specification / Metric | FOR-52 Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| Capacity | 52.0 in span [U.S. Environmental Protection Agency (ENERGY STAR)] | Standard in span rating | Density unavailable |
| Listing & Release | Released 2024 | 2 SKUs | Consolidates 2 finish variants |
| NAHB Service Life | 15 years [National Association of Home Builders (NAHB)] | 50% age gate: 7.5 yrs | Evaluate repair vs net replacement once age passes 9.8 yrs |
| Airflow Efficiency | 179.0 CFM/W | Standard Fan Only | Certified efficiency metric |
Which ceiling fans match FOR-52 in cutout width and energy draw?
Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.
| Peer Model | Subtype | kWh/yr | Delta vs FOR-52 | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| Harbor Breeze 5979020 | Standard Fan Only | Not listed | Not listed | 52.0 in span | Not listed | 1 |
| Globe 37000001 | Standard Fan Only | Not listed | Not listed | 52.0 in span | Not listed | 1 |
| Globe GL37000001 | Standard Fan Only | Not listed | Not listed | 52.0 in span | Not listed | 1 |
| Monte Carlo 3MAVSM52 | Standard Fan Only | Not listed | Not listed | 52.0 in span | Not listed | 1 |
| SNC SNC-CFL01-52BLA1 | Standard Fan with Light Kit | Not listed | Not listed | 52.0 in span | Not listed | 1 |
Does FOR-52 carry R-600a, duct, or installation boundaries?
FOR-52 (Standard Fan Only, 179.0 CFM/W) mounts to a UL-listed fan-rated ceiling electrical box with >= 7 ft blade clearance above floor.
Shut off wall switch and circuit breaker before servicing canopy wiring or balancing downrod blades.
- FOR-52
- FOR-52-****
Should you repair FOR-52 or replace it under the 50% rule?
Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.
FAQ
Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.
How much does running Linari FOR-52 cost each year?
At 18.16 cents/kWh (EIA August 2026), Linari FOR-52 draws certified ENERGY STAR status, equating to scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) across all 2 finish trims, specifically FOR-52, FOR-52-****.
How efficient is Linari FOR-52 compared with federal ceilings?
Measured against 10 CFR 430 certified, Linari FOR-52 holds rank #876 out of 1,241 U.S. ENERGY STAR ceiling fans: -30.9 CFM/W (-14.7%) vs median 0.0 kWh/yr.
Which minor parts are exceptions to replacing Linari FOR-52?
Routine wear items such as gaskets, lint filters, coin traps, or inlet mesh remain worthwhile past 7.5 years, whereas motor or board quotes above 50% net replacement favor replacement.
When is Linari FOR-52 a poor match for a remodel?
Avoid Linari FOR-52 if 52.0 in span falls short of household demand, if hookups conflict with OEM cutout blueprint, or if local electricity tariffs justify the lowest-kWh quartile.
Do all variants in the Linari FOR-52 line use identical energy?
Yes; every listed finish — including FOR-52, FOR-52-**** — shares the identical certified ENERGY STAR status ENERGY STAR test rating and 52.0 in span volume.
What safety codes restrict Linari FOR-52 disassembly?
Always shut off the electrical breaker and water shutoff valve before opening FOR-52 service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.
How should owners confirm cutout clearance for Linari FOR-52?
Verify width, height, and depth against OEM cutout blueprint, leaving extra rear space for cords, hoses, or condenser airflow.
Where is the serial tag located on Linari FOR-52?
Inspect the inner liner wall, door rim, or tub flange via the Linari serial guide to decode build month and year before buying replacement assemblies.
Related guides
Sources
- ENERGY STAR Certified Ceiling Fans Dataset (2te3-nmxp) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
- Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)