Specified at 56.0 in span and Airflow Efficiency 301 CFM/W, Minka Aire F841L-ALW scores higher efficiency than 89.4% of 1,241 ceiling fans in the U.S. ENERGY STAR directory. Shared internal engineering unites single SKU F841L-ALW within a standard residential footprint. Evaluated over a 15-year NAHB benchmark service window, operating power equals rated service expectations across a 15-year NAHB lifespan with ENERGY STAR certified margin under DOE 10 CFR 430.

Rated Energy
Ceiling Fans
EIA Annual Cost
Not listed
Category Rank
#130 of 1,241
Capacity
56.0 in span
NAHB Lifespan
15 years
Annual Energy Draw Certified Rank #130 / 1,241 (top 10.6%)
vs Ceiling Fans Median +91.1 CFM/W (+43.4%) EPA certified comparison
Federal Metric (Airflow Efficiency) 301.0 CFM/W 10 CFR 430 certified
Est. Operating Cost Unrated Annual kWh not listed

What are the official specs and computed benchmarks for Minka Aire F841L-ALW?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.

Minka Aire F841L-ALW — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)
Specification / Metric F841L-ALW Value Category / Federal Benchmark Computed Insight & Formula
Capacity 56.0 in span [U.S. Environmental Protection Agency (ENERGY STAR)] Standard in span rating Density unavailable
Listing & Release Released 2026 1 SKU Single model listing (1 SKU)
NAHB Service Life 15 years [National Association of Home Builders (NAHB)] 50% age gate: 7.5 yrs Evaluate repair vs net replacement once age passes 9.8 yrs
Airflow Efficiency 301.0 CFM/W Standard Fan Only Certified efficiency metric

Which ceiling fans match F841L-ALW in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Ceiling Fans (Matched by Width & kWh Draw)
Peer Model Subtype kWh/yr Delta vs F841L-ALW Capacity Cutout Dimensions SKUs
Monte Carlo 3AOR60 Standard Fan Only Not listed Not listed 60.0 in span Not listed 1
Big Ass Fans MK-HK4-042400 Low-Mount HSSD Fan Only Not listed Not listed 52.0 in span Not listed 1
Hunter 53780 Standard Fan Only Not listed Not listed 60.0 in span Not listed 1
Generation Lighting 4SBWR56 Standard Fan Only Not listed Not listed 56.0 in span Not listed 1
Generation Lighting 4SBWR56XXX Standard Fan Only Not listed Not listed 56.0 in span Not listed 1

Does F841L-ALW carry R-600a, duct, or installation boundaries?

F841L-ALW (Standard Fan Only, 301.0 CFM/W) mounts to a UL-listed fan-rated ceiling electrical box with >= 7 ft blade clearance above floor.

Shut off wall switch and circuit breaker before servicing canopy wiring or balancing downrod blades.

  • F841L-ALW

Should you repair F841L-ALW or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

How much does running Minka Aire F841L-ALW cost each year?

At 18.16 cents/kWh (EIA August 2026), Minka Aire F841L-ALW draws certified ENERGY STAR status, equating to scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) across all 1 finish trim, specifically F841L-ALW.

How efficient is Minka Aire F841L-ALW compared with federal ceilings?

Measured against 10 CFR 430 certified, Minka Aire F841L-ALW holds rank #130 out of 1,241 U.S. ENERGY STAR ceiling fans: +91.1 CFM/W (+43.4%) vs median 0.0 kWh/yr.

Which minor parts are exceptions to replacing Minka Aire F841L-ALW?

Routine wear items such as gaskets, lint filters, coin traps, or inlet mesh remain worthwhile past 7.5 years, whereas motor or board quotes above 50% net replacement favor replacement.

When is Minka Aire F841L-ALW a poor match for a remodel?

Avoid Minka Aire F841L-ALW if 56.0 in span falls short of household demand, if hookups conflict with OEM cutout blueprint, or if local electricity tariffs justify the lowest-kWh quartile.

Do all variants in the Minka Aire F841L-ALW line use identical energy?

Yes; every listed finish — including F841L-ALW — shares the identical certified ENERGY STAR status ENERGY STAR test rating and 56.0 in span volume.

What safety codes restrict Minka Aire F841L-ALW disassembly?

Always shut off the electrical breaker and water shutoff valve before opening F841L-ALW service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

How should owners confirm cutout clearance for Minka Aire F841L-ALW?

Verify width, height, and depth against OEM cutout blueprint, leaving extra rear space for cords, hoses, or condenser airflow.

Where is the serial tag located on Minka Aire F841L-ALW?

Inspect the inner liner wall, door rim, or tub flange via the Minka Aire serial guide to decode build month and year before buying replacement assemblies.

Related guides

Sources

  1. ENERGY STAR Certified Ceiling Fans Dataset (2te3-nmxp) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
  2. Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
  3. Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)