JennAir JICT724 Electric Cooking Specs
JennAir JICT724 (Cooktop) places #75 of 234 certified U.S. electric cooking with 195 kWh/yr ($35.41/yr at 18.16c/kWh) and 4.0 zones. Sized for a 28-inch apartment alcove, this chassis consolidates single SKU JICT724S*** to prevent duplicate parts lookup. Projected electricity totals $460.33 over a 13-year NAHB lifespan at August 2026 EIA rates, keeping ENERGY STAR certified headroom under federal 10 CFR 430 rules.
- Rated Energy
- 195 kWh/yr
- EIA Annual Cost
- $35.41/yr
- Category Rank
- #75 of 234
- Capacity
- 4.0 zones
- NAHB Lifespan
- 13 years
How does JICT724 compare across all 234 electric cooking?
JennAir JICT724 (195 kWh/yr) sits against the electric cooking category median of 195.0 kWh/yr, Equal to median, and U.S. 10 CFR 430 baselines.
View quantile summary for Electric Cooking — JICT724
| Quantile / Marker | Annual kWh/yr |
|---|---|
| Most efficient model | 175 kWh/yr kWh |
| 25th percentile | 190 kWh/yr kWh |
| Category median | 195 kWh/yr kWh |
| 75th percentile | 195 kWh/yr kWh |
| Highest rated draw | 195 kWh/yr kWh |
Where does JICT724 rank in operating-cost percentile?
Ranked #75 of 234 rated electric cooking using EIA August 2026 national residential electricity rates (18.16 cents/kWh) over a 13-year NAHB median lifespan.
What are the official specs and computed benchmarks for JennAir JICT724?
Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (13 years), and estimated operating electricity costs at 18.16 cents/kWh.
| Specification / Metric | JICT724 Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| Rated Energy | 195 kWh/yr [U.S. Environmental Protection Agency (ENERGY STAR)] | Median 195 kWh/yr | Tied with 159 peers at 195 kWh/yr (matches median) |
| Capacity | 4.0 zones [U.S. Environmental Protection Agency (ENERGY STAR)] | Standard zones rating | 48.75 kWh/zones (+2.6% vs 47.5 median) |
| Cutout W × H × D | 25.88 × 3.68 × 21.3 in [U.S. Environmental Protection Agency (ENERGY STAR)] | Released 2025 | Single model listing (1 SKU) |
| Operating Cost (EIA) | $35.41/yr [U.S. Energy Information Administration (EIA)] | 18.16 c/kWh US avg | Formula: 195 kWh × $0.1816 = $35.41/yr ($460.33 over 13 yrs) |
| NAHB Service Life | 13 years [National Association of Home Builders (NAHB)] | 50% age gate: 6.5 yrs | Evaluate repair vs net replacement once age passes 8.5 yrs |
| Boil Test Time | 4.5 min | 240 V | Certified efficiency metric |
Which electric cooking match JICT724 in cutout width and energy draw?
Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.
| Peer Model | Subtype | kWh/yr | Delta vs JICT724 | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| Dacor DOP30*940I | Range | 195 | Same kWh | 4.0 zones | 27.06 × 29.94 × 36.0 in | 1 |
| Haier QAS740*M | Range | 195 | Same kWh | 4.0 zones | 24.0 × 40.75 × 28.13 in | 1 |
| GE JAS640*M | Range | 195 | Same kWh | 4.0 zones | 23.88 × 41.0 × 23.0 in | 1 |
| Whirlpool WCE55US4 | Cooktop | 195 | Same kWh | 4.0 zones | 23.81 × 5.01 × 21.75 in | 1 |
| Hotpoint RAS200*M | Range | 195 | Same kWh | 4.0 zones | 23.75 × 41.88 × 26.63 in | 1 |
Does JICT724 carry R-600a, duct, or installation boundaries?
JICT724 (Cooktop, 240 V, 25.88 in width) fits a standard countertop or slide-in cutout; confirm dedicated 40A-50A breaker ampacity before installation.
Induction glass-ceramic tops require ferromagnetic cookware and dedicated cooling fan clearance; high-voltage 240V IGBT/inverter board service requires a qualified technician.
- JICT724S***
Should you repair JICT724 or replace it under the 50% rule?
Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.
FAQ
Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.
What is the projected 13-year power cost for JennAir JICT724?
Multiplying 195 kWh/yr by the U.S. EIA residential average of 18.16 cents/kWh places JennAir JICT724 running cost at $35.41/yr ($460 over 13 years) over its 13-year NAHB component life.
Does JennAir JICT724 outperform the electric cooking category median?
Against a category median of 195.0 kWh/yr across 234 chassis, JennAir JICT724 stands at rank #75: Equal to median; Tied with 159 peers at 195 kWh/yr (median).
What is the 50% cost threshold for JennAir JICT724 repairs?
Subtract eligible incentives and 5-year energy savings ($150) from replacement retail price, then cap repair quotes at 50% once age exceeds 6.5 years.
Which installations do NOT fit JennAir JICT724?
Skip JennAir JICT724 if your cabinet cutout cannot fit 25.88 × 3.68 × 21.3 in, if 4.0 zones cannot clear household doorways, or if commercial throughput exceeds residential engineering limits.
Why are 1 SKU variants grouped under JennAir JICT724?
Manufacturers file separate paint letters such as JICT724S*** for one mechanical chassis; grouping them shows true 195 kWh/yr and 4.0 zones specs without duplicate model clutter.
Which hazards forbid uncertified work on JennAir JICT724?
Always shut off the electrical breaker and water shutoff valve before opening JICT724 service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.
Can you swap JennAir JICT724 without modifying kitchen framing?
Inspect the 5 nearest peers matched to 25.88 × 3.68 × 21.3 in and 4.0 zones; selecting a peer matching JICT724's width avoids countertop or cabinet trim alterations.
Why screen recall notices for JennAir JICT724 before paid service?
Active CPSC safety notices entitle owners to no-charge OEM remedies; always verify your exact serial number on CPSC recall bulletins before booking out-of-warranty work.
Related guides
Sources
- ENERGY STAR Certified Residential Electric Cooking Products (m6gi-ng33) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
- Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)