SKS SKSIT3601 Electric Cooking Specs
Designed for a 42-inch wide built-in opening at 5.0 zones, SKS SKSIT3601 draws 189 kWh/yr ($34.32/yr at 18.16c/kWh) and ranks -6 kWh/yr (-3.1%) relative to the 195 kWh/yr median among 234 certified electric cooking. Factory color variants map back to single SKU SKSIT3601GE. Pairing ENERGY STAR certified DOE 10 CFR 430 compliance with NAHB median expectancy points to $446.16 over a 13-year NAHB lifespan.
- Rated Energy
- 189 kWh/yr
- EIA Annual Cost
- $34.32/yr
- Category Rank
- #28 of 234
- Capacity
- 5.0 zones
- NAHB Lifespan
- 13 years
How does SKSIT3601 compare across all 234 electric cooking?
SKS SKSIT3601 (189 kWh/yr) sits against the electric cooking category median of 195.0 kWh/yr, -6 kWh/yr (-3.1%), and U.S. 10 CFR 430 baselines.
View quantile summary for Electric Cooking — SKSIT3601
| Quantile / Marker | Annual kWh/yr |
|---|---|
| Most efficient model | 175 kWh/yr kWh |
| 25th percentile | 190 kWh/yr kWh |
| Category median | 195 kWh/yr kWh |
| 75th percentile | 195 kWh/yr kWh |
| Highest rated draw | 195 kWh/yr kWh |
Where does SKSIT3601 rank in operating-cost percentile?
Ranked #28 of 234 rated electric cooking using EIA August 2026 national residential electricity rates (18.16 cents/kWh) over a 13-year NAHB median lifespan.
What are the official specs and computed benchmarks for SKS SKSIT3601?
Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (13 years), and estimated operating electricity costs at 18.16 cents/kWh.
| Specification / Metric | SKSIT3601 Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| Rated Energy | 189 kWh/yr [U.S. Environmental Protection Agency (ENERGY STAR)] | Median 195 kWh/yr | Tied with 26 peers at 189 kWh/yr (-6 kWh/yr, -3.1% vs median) |
| Capacity | 5.0 zones [U.S. Environmental Protection Agency (ENERGY STAR)] | Standard zones rating | 37.8 kWh/zones (-20.4% vs 47.5 median) |
| Cutout W × H × D | 36.63 × 3.56 × 21.06 in [U.S. Environmental Protection Agency (ENERGY STAR)] | Released 2023 | Single model listing (1 SKU) |
| Operating Cost (EIA) | $34.32/yr [U.S. Energy Information Administration (EIA)] | 18.16 c/kWh US avg | Formula: 189 kWh × $0.1816 = $34.32/yr ($446.16 over 13 yrs) |
| NAHB Service Life | 13 years [National Association of Home Builders (NAHB)] | 50% age gate: 6.5 yrs | Evaluate repair vs net replacement once age passes 8.5 yrs |
| Boil Test Time | 3.0 min | 240 V | Certified efficiency metric |
Which electric cooking match SKSIT3601 in cutout width and energy draw?
Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.
| Peer Model | Subtype | kWh/yr | Delta vs SKSIT3601 | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| LG CBIH3613*E | Cooktop | 189 | Same kWh | 5.0 zones | 36.63 × 3.69 × 21.06 in | 1 |
| LG CBIS3618*E | Cooktop | 189 | Same kWh | 5.0 zones | 36.63 × 3.56 × 21.06 in | 1 |
| LG CBIU3639*E | Cooktop | 189 | Same kWh | 5.0 zones | 36.63 × 3.56 × 21.06 in | 1 |
| Signature Kitchen Suite or SKS SKSIT3611 | Cooktop | 189 | Same kWh | 5.0 zones | 36.63 × 3.56 × 21.06 in | 1 |
| LG CBIH3617*E | Cooktop | 190 | +1 kWh | 5.0 zones | 36.63 × 3.69 × 21.06 in | 1 |
Does SKSIT3601 carry R-600a, duct, or installation boundaries?
SKSIT3601 (Cooktop, 240 V, 36.63 in width) fits a standard countertop or slide-in cutout; confirm dedicated 40A-50A breaker ampacity before installation.
Induction glass-ceramic tops require ferromagnetic cookware and dedicated cooling fan clearance; high-voltage 240V IGBT/inverter board service requires a qualified technician.
- SKSIT3601GE
Should you repair SKSIT3601 or replace it under the 50% rule?
Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.
FAQ
Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.
What is the projected 13-year power cost for SKS SKSIT3601?
Multiplying 189 kWh/yr by the U.S. EIA residential average of 18.16 cents/kWh places SKS SKSIT3601 running cost at $34.32/yr ($446 over 13 years) over its 13-year NAHB component life.
Does SKS SKSIT3601 outperform the electric cooking category median?
Against a category median of 195.0 kWh/yr across 234 chassis, SKS SKSIT3601 stands at rank #28: -6 kWh/yr (-3.1%); Rank #28 / 234 (tied with 26 at 189 kWh/yr).
What is the 50% cost threshold for SKS SKSIT3601 repairs?
Subtract eligible incentives and 5-year energy savings ($150) from replacement retail price, then cap repair quotes at 50% once age exceeds 6.5 years.
Which installations do NOT fit SKS SKSIT3601?
Skip SKS SKSIT3601 if your cabinet cutout cannot fit 36.63 × 3.56 × 21.06 in, if 5.0 zones cannot clear household doorways, or if commercial throughput exceeds residential engineering limits.
Why are 1 SKU variants grouped under SKS SKSIT3601?
Manufacturers file separate paint letters such as SKSIT3601GE for one mechanical chassis; grouping them shows true 189 kWh/yr and 5.0 zones specs without duplicate model clutter.
Which hazards forbid uncertified work on SKS SKSIT3601?
Always shut off the electrical breaker and water shutoff valve before opening SKSIT3601 service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.
Can you swap SKS SKSIT3601 without modifying kitchen framing?
Inspect the 5 nearest peers matched to 36.63 × 3.56 × 21.06 in and 5.0 zones; selecting a peer matching SKSIT3601's width avoids countertop or cabinet trim alterations.
Why screen recall notices for SKS SKSIT3601 before paid service?
Active CPSC safety notices entitle owners to no-charge OEM remedies; always verify your exact serial number on CPSC recall bulletins before booking out-of-warranty work.
Related guides
Sources
- ENERGY STAR Certified Residential Electric Cooking Products (m6gi-ng33) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
- Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)