BANGSON US-BSR-019-2 Freezer Specs
Verified EPA ENERGY STAR test logs for BANGSON US-BSR-019-2 list 216 kWh/yr ($39.23/yr at 18.16c/kWh) and 1.1 cu ft, giving this top-quartile efficiency Compact unit clear cost separation at -212 kWh/yr (-49.5%) relative to the 428 kWh/yr median. Built into a standard residential footprint, the assembly covers single SKU US-BSR-019-2. Cumulative power cost runs $431.53 over a 11-year NAHB lifespan while holding -26 kWh (11.0% below) vs 10 CFR 430.
- Rated Energy
- 216 kWh/yr
- EIA Annual Cost
- $39.23/yr
- Category Rank
- #25 of 545
- Capacity
- 1.1 cu ft
- NAHB Lifespan
- 11 years
How does US-BSR-019-2 compare across all 545 freezers?
BANGSON US-BSR-019-2 (216 kWh/yr) sits against the freezers category median of 428.0 kWh/yr, -212 kWh/yr (-49.5%), and U.S. 10 CFR 430 baselines.
View quantile summary for Freezers — US-BSR-019-2
| Quantile / Marker | Annual kWh/yr |
|---|---|
| Most efficient model | 137 kWh/yr kWh |
| 25th percentile | 354 kWh/yr kWh |
| Category median | 428 kWh/yr kWh |
| 75th percentile | 492 kWh/yr kWh |
| Highest rated draw | 649 kWh/yr kWh |
Where does US-BSR-019-2 rank in operating-cost percentile?
Ranked #25 of 545 rated freezers using EIA August 2026 national residential electricity rates (18.16 cents/kWh) over a 11-year NAHB median lifespan.
What are the official specs and computed benchmarks for BANGSON US-BSR-019-2?
Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (11 years), and estimated operating electricity costs at 18.16 cents/kWh.
| Specification / Metric | US-BSR-019-2 Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| Rated Energy | 216 kWh/yr [U.S. Environmental Protection Agency (ENERGY STAR)] | Median 428 kWh/yr | Rank #25 of 545 freezers (tied with 7 peers) (-212 kWh/yr, -49.5% vs median) |
| 10 CFR 430 Ceiling | 242 kWh/yr [U.S. Environmental Protection Agency (ENERGY STAR)] | -26 kWh (11.0% below) | Saves ~$4.72/yr ($24 over 5 yrs) vs federal limit |
| Capacity | 1.1 cu ft [U.S. Environmental Protection Agency (ENERGY STAR)] | Adj. 1.9 cu ft | 196.36 kWh/cu ft (+529.4% vs 31.2 median) |
| Listing & Release | Released 2023 | 1 SKU | Single model listing (1 SKU) |
| Operating Cost (EIA) | $39.23/yr [U.S. Energy Information Administration (EIA)] | 18.16 c/kWh US avg | Formula: 216 kWh × $0.1816 = $39.23/yr ($431.53 over 11 yrs) |
| NAHB Service Life | 11 years [National Association of Home Builders (NAHB)] | 50% age gate: 5.5 yrs | Evaluate repair vs net replacement once age passes 7.2 yrs |
Which freezers match US-BSR-019-2 in cutout width and energy draw?
Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.
| Peer Model | Subtype | kWh/yr | Delta vs US-BSR-019-2 | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| Arctic King AUFM011 | Compact | 215 | -1 kWh | 1.1 cu ft | Not listed | 1 |
| Honeywell H11MFB | Compact | 215 | -1 kWh | 1.1 cu ft | Not listed | 1 |
| Honeywell H11MFS | Compact | 215 | -1 kWh | 1.1 cu ft | Not listed | 1 |
| Honeywell H11MFW | Compact | 215 | -1 kWh | 1.1 cu ft | Not listed | 1 |
| Midea MRU01M3 | Compact | 215 | -1 kWh | 1.1 cu ft | Not listed | 2 |
Does US-BSR-019-2 carry R-600a, duct, or installation boundaries?
US-BSR-019-2 fits a standard residential footprint (full-depth chassis) with manual cooling; keep 1-2 in rear/top condenser airflow clearance.
Sealed-system status for US-BSR-019-2: R-600a. EPA SNAP Rule 22 caps R-600a isobutane charges at 150g under UL 60335-2-24; EPA 608 recovery gear is mandatory for sealed tubing work.
- US-BSR-019-2
Should you repair US-BSR-019-2 or replace it under the 50% rule?
Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.
FAQ
Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.
How much does running BANGSON US-BSR-019-2 cost each year?
At 18.16 cents/kWh (EIA August 2026), BANGSON US-BSR-019-2 draws 216 kWh/yr, equating to $39.23/yr ($432 over 11 years) across all 1 finish trim, specifically US-BSR-019-2.
How efficient is BANGSON US-BSR-019-2 compared with federal ceilings?
Measured against 242 kWh/yr federal ceiling — -26 kWh (11.0% below), BANGSON US-BSR-019-2 holds rank #25 out of 545 U.S. ENERGY STAR freezers: -212 kWh/yr (-49.5%) vs median 428.0 kWh/yr.
Which minor parts are exceptions to replacing BANGSON US-BSR-019-2?
Routine wear items such as gaskets, lint filters, coin traps, or inlet mesh remain worthwhile past 5.5 years, whereas motor or board quotes above 50% net replacement favor replacement.
When is BANGSON US-BSR-019-2 a poor match for a remodel?
Avoid BANGSON US-BSR-019-2 if 1.1 cu ft falls short of household demand, if hookups conflict with OEM cutout blueprint, or if local electricity tariffs justify the lowest-kWh quartile.
Do all variants in the BANGSON US-BSR-019-2 line use identical energy?
Yes; every listed finish — including US-BSR-019-2 — shares the identical 216 kWh/yr ENERGY STAR test rating and 1.1 cu ft volume.
What safety codes restrict BANGSON US-BSR-019-2 disassembly?
Post-2019 cooling chassis like US-BSR-019-2 carry ASHRAE Class A3 flammable R-600a isobutane capped at 150 grams under EPA SNAP Rule 22, so sealed copper tubing requires certified recovery equipment.
How should owners confirm cutout clearance for BANGSON US-BSR-019-2?
Verify width, height, and depth against OEM cutout blueprint, leaving extra rear space for cords, hoses, or condenser airflow.
Where is the serial tag located on BANGSON US-BSR-019-2?
Inspect the inner liner wall, door rim, or tub flange via the BANGSON serial guide to decode build month and year before buying replacement assemblies.
Related guides
Sources
- ENERGY STAR Certified Residential Freezers Dataset (8t9c-g3tn) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-23)
- Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)
- SNAP Substitutes in Household Refrigerators and Freezers (Rule 22, R-600a) — U.S. Environmental Protection Agency (EPA), SNAP Rule 22 (retrieved 2026-11-23)