Mora MFU140N6 Freezer Specs
Spanning single SKU MFU140N6AWE, Mora MFU140N6 logs 391 kWh/yr ($71.01/yr at 18.16c/kWh) inside a standard residential footprint built for 13.6 cu ft. Out of 545 certified U.S. freezers, this Upright Freezer model achieves upper-half efficiency: #167 / 545 — tied with 14 peers, uses less energy than 66.8% of 545 freezers. Out-of-warranty owners weighing component quotes face $781.11 over a 11-year NAHB lifespan and -43 kWh (10.0% below) compliance under 10 CFR 430.
- Rated Energy
- 391 kWh/yr
- EIA Annual Cost
- $71.01/yr
- Category Rank
- #167 of 545
- Capacity
- 13.6 cu ft
- NAHB Lifespan
- 11 years
How does MFU140N6 compare across all 545 freezers?
Mora MFU140N6 (391 kWh/yr) sits against the freezers category median of 428.0 kWh/yr, -37 kWh/yr (-8.6%), and U.S. 10 CFR 430 baselines.
View quantile summary for Freezers — MFU140N6
| Quantile / Marker | Annual kWh/yr |
|---|---|
| Most efficient model | 137 kWh/yr kWh |
| 25th percentile | 354 kWh/yr kWh |
| Category median | 428 kWh/yr kWh |
| 75th percentile | 492 kWh/yr kWh |
| Highest rated draw | 649 kWh/yr kWh |
Where does MFU140N6 rank in operating-cost percentile?
Ranked #167 of 545 rated freezers using EIA August 2026 national residential electricity rates (18.16 cents/kWh) over a 11-year NAHB median lifespan.
What are the official specs and computed benchmarks for Mora MFU140N6?
Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (11 years), and estimated operating electricity costs at 18.16 cents/kWh.
| Specification / Metric | MFU140N6 Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| Rated Energy | 391 kWh/yr [U.S. Environmental Protection Agency (ENERGY STAR)] | Median 428 kWh/yr | Tied with 14 peers at 391 kWh/yr (-37 kWh/yr, -8.6% vs median) |
| 10 CFR 430 Ceiling | 434 kWh/yr [U.S. Environmental Protection Agency (ENERGY STAR)] | -43 kWh (10.0% below) | Saves ~$7.81/yr ($39 over 5 yrs) vs federal limit |
| Capacity | 13.6 cu ft [U.S. Environmental Protection Agency (ENERGY STAR)] | Adj. 23.9 cu ft | 28.75 kWh/cu ft (-7.9% vs 31.2 median) |
| Listing & Release | Released 2023 | 1 SKU | Single model listing (1 SKU) |
| Operating Cost (EIA) | $71.01/yr [U.S. Energy Information Administration (EIA)] | 18.16 c/kWh US avg | Formula: 391 kWh × $0.1816 = $71.01/yr ($781.11 over 11 yrs) |
| NAHB Service Life | 11 years [National Association of Home Builders (NAHB)] | 50% age gate: 5.5 yrs | Evaluate repair vs net replacement once age passes 7.2 yrs |
Which freezers match MFU140N6 in cutout width and energy draw?
Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.
| Peer Model | Subtype | kWh/yr | Delta vs MFU140N6 | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| Elisii DECVC138 | Upright Freezer | 391 | Same kWh | 13.6 cu ft | Not listed | 1 |
| Forno FFFFD1722-28BLK-L | Upright Freezer | 391 | Same kWh | 13.6 cu ft | Not listed | 1 |
| Forno FFFFD1722-28BLK-R | Upright Freezer | 391 | Same kWh | 13.6 cu ft | Not listed | 1 |
| Forno FFFFD1722-28L | Upright Freezer | 391 | Same kWh | 13.6 cu ft | Not listed | 1 |
| Forno FFFFD1722-28R | Upright Freezer | 391 | Same kWh | 13.6 cu ft | Not listed | 1 |
Does MFU140N6 carry R-600a, duct, or installation boundaries?
MFU140N6 fits a standard residential footprint (full-depth chassis) with automatic cooling; keep 1-2 in rear/top condenser airflow clearance.
Sealed-system status for MFU140N6: R-600a era (post-2019). EPA SNAP Rule 22 caps R-600a isobutane charges at 150g under UL 60335-2-24; EPA 608 recovery gear is mandatory for sealed tubing work.
- MFU140N6AWE
Should you repair MFU140N6 or replace it under the 50% rule?
Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.
FAQ
Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.
What is the projected 11-year power cost for Mora MFU140N6?
Multiplying 391 kWh/yr by the U.S. EIA residential average of 18.16 cents/kWh places Mora MFU140N6 running cost at $71.01/yr ($781 over 11 years) over its 11-year NAHB component life.
Does Mora MFU140N6 outperform the freezers category median?
Against a category median of 428.0 kWh/yr across 545 chassis, Mora MFU140N6 stands at rank #167: -37 kWh/yr (-8.6%); Rank #167 / 545 (tied with 14 at 391 kWh/yr).
What is the 50% cost threshold for Mora MFU140N6 repairs?
Subtract eligible incentives and 5-year energy savings ($39) from replacement retail price, then cap repair quotes at 50% once age exceeds 5.5 years.
Which installations do NOT fit Mora MFU140N6?
Skip Mora MFU140N6 if your cabinet cutout cannot fit OEM cutout blueprint, if 13.6 cu ft cannot clear household doorways, or if commercial throughput exceeds residential engineering limits.
Why are 1 SKU variants grouped under Mora MFU140N6?
Manufacturers file separate paint letters such as MFU140N6AWE for one mechanical chassis; grouping them shows true 391 kWh/yr and 13.6 cu ft specs without duplicate model clutter.
Which hazards forbid uncertified work on Mora MFU140N6?
Post-2019 cooling chassis like MFU140N6 carry ASHRAE Class A3 flammable R-600a isobutane capped at 150 grams under EPA SNAP Rule 22, so sealed copper tubing requires certified recovery equipment.
Can you swap Mora MFU140N6 without modifying kitchen framing?
Inspect the 5 nearest peers matched to OEM cutout blueprint and 13.6 cu ft; selecting a peer matching MFU140N6's width avoids countertop or cabinet trim alterations.
Why screen recall notices for Mora MFU140N6 before paid service?
Active CPSC safety notices entitle owners to no-charge OEM remedies; always verify your exact serial number on CPSC recall bulletins before booking out-of-warranty work.
Related guides
Sources
- ENERGY STAR Certified Residential Freezers Dataset (8t9c-g3tn) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-23)
- Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)
- SNAP Substitutes in Household Refrigerators and Freezers (Rule 22, R-600a) — U.S. Environmental Protection Agency (EPA), SNAP Rule 22 (retrieved 2026-11-23)