Designed for a standard residential footprint at 22.3 cu ft, Thermador T36IF100SP draws 536 kWh/yr ($97.34/yr at 18.16c/kWh) and ranks +108 kWh/yr (+25.2%) relative to the 428 kWh/yr median among 545 certified freezers. Factory color variants map back to single SKU T36IF100SP. Pairing -195 kWh (28.0% below) DOE 10 CFR 430 compliance with NAHB median expectancy points to $1,070.74 over a 11-year NAHB lifespan.
- Rated Energy
- 536 kWh/yr
- EIA Annual Cost
- $97.34/yr
- Category Rank
- #498 of 545
- Capacity
- 22.3 cu ft
- NAHB Lifespan
- 11 years
How does T36IF100SP compare across all 545 freezers?
Thermador T36IF100SP (536 kWh/yr) sits against the freezers category median of 428.0 kWh/yr, +108 kWh/yr (+25.2%), and U.S. 10 CFR 430 baselines.
View quantile summary for Freezers — T36IF100SP
| Quantile / Marker | Annual kWh/yr |
|---|---|
| Most efficient model | 137 kWh/yr kWh |
| 25th percentile | 354 kWh/yr kWh |
| Category median | 428 kWh/yr kWh |
| 75th percentile | 492 kWh/yr kWh |
| Highest rated draw | 649 kWh/yr kWh |
Where does T36IF100SP rank in operating-cost percentile?
Ranked #498 of 545 rated freezers using EIA August 2026 national residential electricity rates (18.16 cents/kWh) over a 11-year NAHB median lifespan.
What are the official specs and computed benchmarks for Thermador T36IF100SP?
Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (11 years), and estimated operating electricity costs at 18.16 cents/kWh.
| Specification / Metric | T36IF100SP Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| Rated Energy | 536 kWh/yr [U.S. Environmental Protection Agency (ENERGY STAR)] | Median 428 kWh/yr | Rank #498 of 545 freezers (tied with 2 peers) (+108 kWh/yr, +25.2% vs median) |
| 10 CFR 430 Ceiling | 731 kWh/yr [U.S. Environmental Protection Agency (ENERGY STAR)] | -195 kWh (28.0% below) | Saves ~$35.41/yr ($177 over 5 yrs) vs federal limit |
| Capacity | 22.3 cu ft [U.S. Environmental Protection Agency (ENERGY STAR)] | Adj. 39.2 cu ft | 24.04 kWh/cu ft (-22.9% vs 31.2 median) |
| Listing & Release | Released 2026 | 1 SKU | Single model listing (1 SKU) |
| Operating Cost (EIA) | $97.34/yr [U.S. Energy Information Administration (EIA)] | 18.16 c/kWh US avg | Formula: 536 kWh × $0.1816 = $97.34/yr ($1,070.74 over 11 yrs) |
| NAHB Service Life | 11 years [National Association of Home Builders (NAHB)] | 50% age gate: 5.5 yrs | Evaluate repair vs net replacement once age passes 7.2 yrs |
Which freezers match T36IF100SP in cutout width and energy draw?
Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.
| Peer Model | Subtype | kWh/yr | Delta vs T36IF100SP | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| Gaggenau RVF497790 | Upright Freezer | 536 | Same kWh | 22.3 cu ft | Not listed | 1 |
| Miele FMC3842L | Upright Freezer | 536 | Same kWh | 22.3 cu ft | Not listed | 1 |
| Liebherr MF 3661 | Upright Freezer | 535 | -1 kWh | 18.9 cu ft | Not listed | 1 |
| Gaggenau RF491704 | Upright Freezer | 543 | +7 kWh | 19.4 cu ft | Not listed | 1 |
| Miele F 2901 VI | Upright Freezer | 543 | +7 kWh | 19.4 cu ft | Not listed | 1 |
Does T36IF100SP carry R-600a, duct, or installation boundaries?
T36IF100SP fits a standard residential footprint (full-depth chassis) with automatic cooling; keep 1-2 in rear/top condenser airflow clearance.
Sealed-system status for T36IF100SP: R-600a. EPA SNAP Rule 22 caps R-600a isobutane charges at 150g under UL 60335-2-24; EPA 608 recovery gear is mandatory for sealed tubing work.
- T36IF100SP
Should you repair T36IF100SP or replace it under the 50% rule?
Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.
Which CPSC safety recalls match Thermador equipment?
Active U.S. Consumer Product Safety Commission notices mentioning Thermador; verify serial eligibility on CPSC.gov before paying out-of-warranty dispatch charges.
- 10118 (2010-01-21) — BSH Home Appliances Corp. Expands Recall of Thermador Built-In Ovens Due to Fire Hazard
- 07228 (2007-06-29) — Fire Hazard with Thermador® Built-In Ovens Leads to Recall by BSH Home Appliances Corp.
FAQ
Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.
What is the projected 11-year power cost for Thermador T36IF100SP?
Multiplying 536 kWh/yr by the U.S. EIA residential average of 18.16 cents/kWh places Thermador T36IF100SP running cost at $97.34/yr ($1,071 over 11 years) over its 11-year NAHB component life.
Does Thermador T36IF100SP outperform the freezers category median?
Against a category median of 428.0 kWh/yr across 545 chassis, Thermador T36IF100SP stands at rank #498: +108 kWh/yr (+25.2%); Rank #498 / 545 (lower half).
What is the 50% cost threshold for Thermador T36IF100SP repairs?
Subtract eligible incentives and 5-year energy savings ($177) from replacement retail price, then cap repair quotes at 50% once age exceeds 5.5 years.
Which installations do NOT fit Thermador T36IF100SP?
Skip Thermador T36IF100SP if your cabinet cutout cannot fit OEM cutout blueprint, if 22.3 cu ft cannot clear household doorways, or if commercial throughput exceeds residential engineering limits.
Why are 1 SKU variants grouped under Thermador T36IF100SP?
Manufacturers file separate paint letters such as T36IF100SP for one mechanical chassis; grouping them shows true 536 kWh/yr and 22.3 cu ft specs without duplicate model clutter.
Which hazards forbid uncertified work on Thermador T36IF100SP?
Post-2019 cooling chassis like T36IF100SP carry ASHRAE Class A3 flammable R-600a isobutane capped at 150 grams under EPA SNAP Rule 22, so sealed copper tubing requires certified recovery equipment.
Can you swap Thermador T36IF100SP without modifying kitchen framing?
Inspect the 5 nearest peers matched to OEM cutout blueprint and 22.3 cu ft; selecting a peer matching T36IF100SP's width avoids countertop or cabinet trim alterations.
Why screen recall notices for Thermador T36IF100SP before paid service?
Active CPSC safety notices entitle owners to no-charge OEM remedies; always verify your exact serial number on CPSC recall bulletins before booking out-of-warranty work.
Related guides
Sources
- ENERGY STAR Certified Residential Freezers Dataset (8t9c-g3tn) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-23)
- Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)
- SNAP Substitutes in Household Refrigerators and Freezers (Rule 22, R-600a) — U.S. Environmental Protection Agency (EPA), SNAP Rule 22 (retrieved 2026-11-23)
- CPSC Recalls REST Web Services API (SaferProducts.gov) — U.S. Consumer Product Safety Commission (CPSC), REST JSON 2026 (retrieved 2026-11-23)