Skip to main content
Room Air Conditioners · Rank #294 of 560

GE Appliances AWHV12 Room Air Conditioner Specs

Specified at 12000.0 BTU/hr and 562 kWh/yr ($102.15/yr at 18.16c/kWh), GE Appliances AWHV12 #294 / 560 — tied with 28 peers, uses less energy than 42.5% of 560 room air conditioners in the U.S. ENERGY STAR directory. Shared internal engineering unites single SKU AWHV12***# within an 18-inch compact alcove. Evaluated over a 10-year NAHB benchmark service window, operating power equals $1,021.50 over a 10-year NAHB lifespan with 47% below limit margin under DOE 10 CFR 430.

Rated Energy
562 kWh/yr
EIA Annual Cost
$102.15/yr
Category Rank
#294 of 560
Capacity
12000.0 BTU/hr
NAHB Lifespan
10 years
Annual Energy Draw 562 kWh/yr Rank #294 / 560 (tied with 28 at 562.5 kWh/yr)
vs Room Air Conditioners Median +31 kWh/yr (+5.8%) Median 531.9 kWh/yr
Federal Metric (CEER) 16.0 BTU/Wh 10 CFR 430 certified
Est. Operating Cost $102.15/yr $1,022 over 10 yr NAHB

How does AWHV12 compare across all 560 room air conditioners?

GE Appliances AWHV12 (562 kWh/yr) sits against the room air conditioners category median of 531.9 kWh/yr, +31 kWh/yr (+5.8%), and U.S. 10 CFR 430 baselines.

AWHV12 vs Room Air Conditioners Energy Distribution Chart of 560 room air conditioners from 260.4 to 2096.3 kWh/yr; median is 531.9 kWh/yr. 260-392 kWh/yr: 80 models 392-523 kWh/yr: 187 models 523-654 kWh/yr: 158 models 654-785 kWh/yr: 60 models 785-916 kWh/yr: 22 models 916-1047 kWh/yr: 11 models 1047-1178 kWh/yr: 2 models 1178-1309 kWh/yr: 14 models 1309-1441 kWh/yr: 20 models 1441-1572 kWh/yr: 2 models 1572-1703 kWh/yr: 2 models 1703-1834 kWh/yr: 0 models 1834-1965 kWh/yr: 1 models 1965-2096 kWh/yr: 1 modelsMedian 531.9 This model (562.5) 260.4 kWh/yrRoom Air Conditioners annual energy spread (n=560)2096.3 kWh/yr
View quantile summary for Room Air Conditioners — AWHV12
Quantile / MarkerAnnual kWh/yr
Most efficient model260.4 kWh/yr kWh
25th percentile404.8 kWh/yr kWh
Category median531.9 kWh/yr kWh
75th percentile647.5 kWh/yr kWh
Highest rated draw2096.3 kWh/yr kWh

Where does AWHV12 rank in operating-cost percentile?

Ranked #294 of 560 rated room air conditioners using EIA August 2026 national residential electricity rates (18.16 cents/kWh) over a 10-year NAHB median lifespan.

AWHV12 Efficiency Percentile 562 kWh/yr ranks #294 of 560 peers (Better than 48%). Higher draw (#560) Median: 531.9 kWh/yr Best (#1) 562 kWh/yr (Better than 48%)

What are the official specs and computed benchmarks for GE Appliances AWHV12?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (10 years), and estimated operating electricity costs at 18.16 cents/kWh.

GE Appliances AWHV12 — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)
Specification / Metric AWHV12 Value Category / Federal Benchmark Computed Insight & Formula
Rated Energy 562 kWh/yr [U.S. Environmental Protection Agency (ENERGY STAR)] Median 532 kWh/yr Tied with 28 peers at 562 kWh/yr (+31 kWh/yr, +5.8% vs median)
Capacity 12000.0 BTU/hr [U.S. Environmental Protection Agency (ENERGY STAR)] Standard BTU/hr rating 0.05 kWh/BTU/hr (matches 0.05 median)
Cutout W × H × D 19.0 × 15.0 × 20.5 in [U.S. Environmental Protection Agency (ENERGY STAR)] Released 2026 Single model listing (1 SKU)
Operating Cost (EIA) $102.15/yr [U.S. Energy Information Administration (EIA)] 18.16 c/kWh US avg Formula: 562 kWh × $0.1816 = $102.15/yr ($1,021.50 over 10 yrs)
NAHB Service Life 10 years [National Association of Home Builders (NAHB)] 50% age gate: 5.0 yrs Evaluate repair vs net replacement once age passes 6.5 yrs
CEER 16.0 BTU/Wh 115 Certified efficiency metric

Which room air conditioners match AWHV12 in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Room Air Conditioners (Matched by Width & kWh Draw)
Peer Model Subtype kWh/yr Delta vs AWHV12 Capacity Cutout Dimensions SKUs
Midea MWEUWA-12CRFN8-BCP0 Window 562 Same kWh 12000.0 BTU/hr 19.1 × 14.6 × 21.8 in 1
Frigidaire Gallery GHWW125TF1 Window 562 Same kWh 12000.0 BTU/hr 19.2 × 13.5 × 22.0 in 1
Midea MAW12Q1 Window 562 Same kWh 12000.0 BTU/hr 19.2 × 13.5 × 22.0 in 1
Midea MAW12U1KWT Window 562 Same kWh 12000.0 BTU/hr 19.2 × 13.5 × 22.0 in 3
Midea MAW12V1KYWT- Window 562 Same kWh 12000.0 BTU/hr 19.2 × 13.5 × 22.0 in 1

Does AWHV12 carry R-600a, duct, or installation boundaries?

AWHV12 (Window, 19.0 in width, CEER 16.0) cools matched room square footage efficiently using R-32 refrigerant.

Sealed refrigerant lines (R-32) are non-serviceable for DIY; keep washable intake filters and outdoor condenser fins clean every 30 days.

  • AWHV12***#

Should you repair AWHV12 or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

Which CPSC safety recalls match GE Appliances equipment?

Active U.S. Consumer Product Safety Commission notices mentioning GE Appliances; verify serial eligibility on CPSC.gov before paying out-of-warranty dispatch charges.

FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

What is the projected 10-year power cost for GE Appliances AWHV12?

Multiplying 562.5 kWh/yr by the U.S. EIA residential average of 18.16 cents/kWh places GE Appliances AWHV12 running cost at $102.15/yr ($1,022 over 10 years) over its 10-year NAHB component life.

Does GE Appliances AWHV12 outperform the room air conditioners category median?

Against a category median of 531.9 kWh/yr across 560 chassis, GE Appliances AWHV12 stands at rank #294: +31 kWh/yr (+5.8%); Rank #294 / 560 (tied with 28 at 562.5 kWh/yr).

What is the 50% cost threshold for GE Appliances AWHV12 repairs?

Subtract eligible incentives and 5-year energy savings ($150) from replacement retail price, then cap repair quotes at 50% once age exceeds 5.0 years.

Which installations do NOT fit GE Appliances AWHV12?

Skip GE Appliances AWHV12 if your cabinet cutout cannot fit 19.0 × 15.0 × 20.5 in, if 12000.0 BTU/hr cannot clear household doorways, or if commercial throughput exceeds residential engineering limits.

Why are 1 SKU variants grouped under GE Appliances AWHV12?

Manufacturers file separate paint letters such as AWHV12***# for one mechanical chassis; grouping them shows true 562.5 kWh/yr and 12000.0 BTU/hr specs without duplicate model clutter.

Which hazards forbid uncertified work on GE Appliances AWHV12?

Always shut off the electrical breaker and water shutoff valve before opening AWHV12 service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

Can you swap GE Appliances AWHV12 without modifying kitchen framing?

Inspect the 5 nearest peers matched to 19.0 × 15.0 × 20.5 in and 12000.0 BTU/hr; selecting a peer matching AWHV12's width avoids countertop or cabinet trim alterations.

Why screen recall notices for GE Appliances AWHV12 before paid service?

Active CPSC safety notices entitle owners to no-charge OEM remedies; always verify your exact serial number on CPSC recall bulletins before booking out-of-warranty work.

Related guides

Sources

  1. ENERGY STAR Certified Room Air Conditioners Dataset (5xn2-dv4h) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
  2. Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
  3. Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)
  4. CPSC Recalls REST Web Services API (SaferProducts.gov) — U.S. Consumer Product Safety Commission (CPSC), REST JSON 2026 (retrieved 2026-11-23)