GE Appliances AWP12P Room Air Conditioner Specs
Spanning single SKU AWP12P***#, GE Appliances AWP12P logs 573 kWh/yr ($104.04/yr at 18.16c/kWh) inside an 18-inch compact alcove built for 11000.0 BTU/hr. Out of 560 certified U.S. room air conditioners, this Window model achieves higher-draw: uses less energy than 42% of 560 room air conditioners. Out-of-warranty owners weighing component quotes face $1,040.40 over a 10-year NAHB lifespan and 47% below limit compliance under 10 CFR 430.
- Rated Energy
- 573 kWh/yr
- EIA Annual Cost
- $104.04/yr
- Category Rank
- #325 of 560
- Capacity
- 11000.0 BTU/hr
- NAHB Lifespan
- 10 years
How does AWP12P compare across all 560 room air conditioners?
GE Appliances AWP12P (573 kWh/yr) sits against the room air conditioners category median of 531.9 kWh/yr, +41 kWh/yr (+7.7%), and U.S. 10 CFR 430 baselines.
View quantile summary for Room Air Conditioners — AWP12P
| Quantile / Marker | Annual kWh/yr |
|---|---|
| Most efficient model | 260.4 kWh/yr kWh |
| 25th percentile | 404.8 kWh/yr kWh |
| Category median | 531.9 kWh/yr kWh |
| 75th percentile | 647.5 kWh/yr kWh |
| Highest rated draw | 2096.3 kWh/yr kWh |
Where does AWP12P rank in operating-cost percentile?
Ranked #325 of 560 rated room air conditioners using EIA August 2026 national residential electricity rates (18.16 cents/kWh) over a 10-year NAHB median lifespan.
What are the official specs and computed benchmarks for GE Appliances AWP12P?
Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (10 years), and estimated operating electricity costs at 18.16 cents/kWh.
| Specification / Metric | AWP12P Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| Rated Energy | 573 kWh/yr [U.S. Environmental Protection Agency (ENERGY STAR)] | Median 532 kWh/yr | Rank #325 of 560 room air conditioners (+41 kWh/yr, +7.7% vs median) |
| Capacity | 11000.0 BTU/hr [U.S. Environmental Protection Agency (ENERGY STAR)] | Standard BTU/hr rating | 0.05 kWh/BTU/hr (matches 0.05 median) |
| Cutout W × H × D | 19.0 × 15.0 × 20.5 in [U.S. Environmental Protection Agency (ENERGY STAR)] | Released 2026 | Single model listing (1 SKU) |
| Operating Cost (EIA) | $104.04/yr [U.S. Energy Information Administration (EIA)] | 18.16 c/kWh US avg | Formula: 573 kWh × $0.1816 = $104.04/yr ($1,040.40 over 10 yrs) |
| NAHB Service Life | 10 years [National Association of Home Builders (NAHB)] | 50% age gate: 5.0 yrs | Evaluate repair vs net replacement once age passes 6.5 yrs |
| CEER | 14.4 BTU/Wh | 115 | Certified efficiency metric |
Which room air conditioners match AWP12P in cutout width and energy draw?
Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.
| Peer Model | Subtype | kWh/yr | Delta vs AWP12P | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| GE Appliances AWGP12 | Window | 625 | +52 kWh | 11000.0 BTU/hr | 19.0 × 15.0 × 20.5 in | 1 |
| Friedrich WCVT10B10 | Through the Wall | 635 | +62 kWh | 11000.0 BTU/hr | 26.5 × 15.2 × 21.0 in | 1 |
| Friedrich WCVT10B30 | Through the Wall | 640 | +68 kWh | 11100.0 BTU/hr | 26.5 × 15.2 × 21.0 in | 1 |
| Friedrich WCVT12B10 | Through the Wall | 596 | +23 kWh | 11200.0 BTU/hr | 26.0 × 18.0 × 29.0 in | 1 |
| K�hl+ KHVS10B11 | Window | 530 | -43 kWh | 10600.0 BTU/hr | 25.9 × 15.9 × 29.0 in | 1 |
Does AWP12P carry R-600a, duct, or installation boundaries?
AWP12P (Window, 19.0 in width, CEER 14.4) cools matched room square footage efficiently using R-32 refrigerant.
Sealed refrigerant lines (R-32) are non-serviceable for DIY; keep washable intake filters and outdoor condenser fins clean every 30 days.
- AWP12P***#
Should you repair AWP12P or replace it under the 50% rule?
Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.
Which CPSC safety recalls match GE Appliances equipment?
Active U.S. Consumer Product Safety Commission notices mentioning GE Appliances; verify serial eligibility on CPSC.gov before paying out-of-warranty dispatch charges.
- 22117 (2022-04-14) — GE Appliances, a Haier Company, Recalls Bottom Freezer, French Door Refrigerators Due to Fall Hazard
- 16265 (2016-09-15) — GE Appliances Recalls Top-Loading Clothes Washers Due to Fire Hazard
- 12244 (2012-08-09) — GE Recalls Dishwashers Due to Fire Hazard
- 11022 (2010-10-26) — GE Recalls Dishwashers Due to Fire Hazard
FAQ
Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.
What is the projected 10-year power cost for GE Appliances AWP12P?
Multiplying 572.9 kWh/yr by the U.S. EIA residential average of 18.16 cents/kWh places GE Appliances AWP12P running cost at $104.04/yr ($1,040 over 10 years) over its 10-year NAHB component life.
Does GE Appliances AWP12P outperform the room air conditioners category median?
Against a category median of 531.9 kWh/yr across 560 chassis, GE Appliances AWP12P stands at rank #325: +41 kWh/yr (+7.7%); Rank #325 / 560 (lower half).
What is the 50% cost threshold for GE Appliances AWP12P repairs?
Subtract eligible incentives and 5-year energy savings ($150) from replacement retail price, then cap repair quotes at 50% once age exceeds 5.0 years.
Which installations do NOT fit GE Appliances AWP12P?
Skip GE Appliances AWP12P if your cabinet cutout cannot fit 19.0 × 15.0 × 20.5 in, if 11000.0 BTU/hr cannot clear household doorways, or if commercial throughput exceeds residential engineering limits.
Why are 1 SKU variants grouped under GE Appliances AWP12P?
Manufacturers file separate paint letters such as AWP12P***# for one mechanical chassis; grouping them shows true 572.9 kWh/yr and 11000.0 BTU/hr specs without duplicate model clutter.
Which hazards forbid uncertified work on GE Appliances AWP12P?
Always shut off the electrical breaker and water shutoff valve before opening AWP12P service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.
Can you swap GE Appliances AWP12P without modifying kitchen framing?
Inspect the 5 nearest peers matched to 19.0 × 15.0 × 20.5 in and 11000.0 BTU/hr; selecting a peer matching AWP12P's width avoids countertop or cabinet trim alterations.
Why screen recall notices for GE Appliances AWP12P before paid service?
Active CPSC safety notices entitle owners to no-charge OEM remedies; always verify your exact serial number on CPSC recall bulletins before booking out-of-warranty work.
Related guides
Sources
- ENERGY STAR Certified Room Air Conditioners Dataset (5xn2-dv4h) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
- Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)
- CPSC Recalls REST Web Services API (SaferProducts.gov) — U.S. Consumer Product Safety Commission (CPSC), REST JSON 2026 (retrieved 2026-11-23)