Keystone KSTAW141 Room Air Conditioner Specs
Specified at 14000.0 BTU/hr and 700 kWh/yr ($127.12/yr at 18.16c/kWh), Keystone KSTAW141 #448 / 560 — tied with 15 peers, uses less energy than 17.3% of 560 room air conditioners in the U.S. ENERGY STAR directory. Shared internal engineering unites single SKU KSTAW141WA within a 24-inch compact alcove. Evaluated over a 10-year NAHB benchmark service window, operating power equals $1,271.20 over a 10-year NAHB lifespan with 40% below limit margin under DOE 10 CFR 430.
- Rated Energy
- 700 kWh/yr
- EIA Annual Cost
- $127.12/yr
- Category Rank
- #448 of 560
- Capacity
- 14000.0 BTU/hr
- NAHB Lifespan
- 10 years
How does KSTAW141 compare across all 560 room air conditioners?
Keystone KSTAW141 (700 kWh/yr) sits against the room air conditioners category median of 531.9 kWh/yr, +168 kWh/yr (+31.6%), and U.S. 10 CFR 430 baselines.
View quantile summary for Room Air Conditioners — KSTAW141
| Quantile / Marker | Annual kWh/yr |
|---|---|
| Most efficient model | 260.4 kWh/yr kWh |
| 25th percentile | 404.8 kWh/yr kWh |
| Category median | 531.9 kWh/yr kWh |
| 75th percentile | 647.5 kWh/yr kWh |
| Highest rated draw | 2096.3 kWh/yr kWh |
Where does KSTAW141 rank in operating-cost percentile?
Ranked #448 of 560 rated room air conditioners using EIA August 2026 national residential electricity rates (18.16 cents/kWh) over a 10-year NAHB median lifespan.
What are the official specs and computed benchmarks for Keystone KSTAW141?
Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (10 years), and estimated operating electricity costs at 18.16 cents/kWh.
| Specification / Metric | KSTAW141 Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| Rated Energy | 700 kWh/yr [U.S. Environmental Protection Agency (ENERGY STAR)] | Median 532 kWh/yr | Tied with 15 peers at 700 kWh/yr (+168 kWh/yr, +31.6% vs median) |
| Capacity | 14000.0 BTU/hr [U.S. Environmental Protection Agency (ENERGY STAR)] | Standard BTU/hr rating | 0.05 kWh/BTU/hr (matches 0.05 median) |
| Cutout W × H × D | 21.7 × 14.7 × 19.0 in [U.S. Environmental Protection Agency (ENERGY STAR)] | Released 2024 | Single model listing (1 SKU) |
| Operating Cost (EIA) | $127.12/yr [U.S. Energy Information Administration (EIA)] | 18.16 c/kWh US avg | Formula: 700 kWh × $0.1816 = $127.12/yr ($1,271.20 over 10 yrs) |
| NAHB Service Life | 10 years [National Association of Home Builders (NAHB)] | 50% age gate: 5.0 yrs | Evaluate repair vs net replacement once age passes 6.5 yrs |
| CEER | 15.0 BTU/Wh | 115 | Certified efficiency metric |
Which room air conditioners match KSTAW141 in cutout width and energy draw?
Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.
| Peer Model | Subtype | kWh/yr | Delta vs KSTAW141 | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| Danby DAC140EBI | Window | 700 | Same kWh | 14000.0 BTU/hr | 21.7 × 14.7 × 19.0 in | 1 |
| ELEMENT EHWR14 | Window | 700 | Same kWh | 14000.0 BTU/hr | 21.7 × 14.7 × 19.0 in | 1 |
| Keplerx KARC14RSVE1 | Window | 700 | Same kWh | 14000.0 BTU/hr | 21.7 × 14.7 × 19.0 in | 1 |
| Midea 1014634880 | Window | 700 | Same kWh | 14000.0 BTU/hr | 21.7 × 14.7 × 19.0 in | 1 |
| Midea MAW14R1VWT | Window | 700 | Same kWh | 14000.0 BTU/hr | 21.7 × 14.7 × 19.0 in | 1 |
Does KSTAW141 carry R-600a, duct, or installation boundaries?
KSTAW141 (Window, 21.7 in width, CEER 15.0) cools matched room square footage efficiently using R-32 refrigerant.
Sealed refrigerant lines (R-32) are non-serviceable for DIY; keep washable intake filters and outdoor condenser fins clean every 30 days.
- KSTAW141WA
Should you repair KSTAW141 or replace it under the 50% rule?
Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.
Which CPSC safety recalls match Keystone equipment?
Active U.S. Consumer Product Safety Commission notices mentioning Keystone; verify serial eligibility on CPSC.gov before paying out-of-warranty dispatch charges.
- 07577 (2007-09-12) — Keystone Manufacturing Co. and QVC Recall Convection Ovens with Rotisserie Due to Fire and Electrical Shock Hazards
FAQ
Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.
How much does running Keystone KSTAW141 cost each year?
At 18.16 cents/kWh (EIA August 2026), Keystone KSTAW141 draws 700 kWh/yr, equating to $127.12/yr ($1,271 over 10 years) across all 1 finish trim, specifically KSTAW141WA.
How efficient is Keystone KSTAW141 compared with federal ceilings?
Measured against 10 CFR 430 certified, Keystone KSTAW141 holds rank #448 out of 560 U.S. ENERGY STAR room air conditioners: +168 kWh/yr (+31.6%) vs median 531.9 kWh/yr.
Which minor parts are exceptions to replacing Keystone KSTAW141?
Routine wear items such as gaskets, lint filters, coin traps, or inlet mesh remain worthwhile past 5.0 years, whereas motor or board quotes above 50% net replacement favor replacement.
When is Keystone KSTAW141 a poor match for a remodel?
Avoid Keystone KSTAW141 if 14000.0 BTU/hr falls short of household demand, if hookups conflict with 21.7 × 14.7 × 19.0 in, or if local electricity tariffs justify the lowest-kWh quartile.
Do all variants in the Keystone KSTAW141 line use identical energy?
Yes; every listed finish — including KSTAW141WA — shares the identical 700 kWh/yr ENERGY STAR test rating and 14000.0 BTU/hr volume.
What safety codes restrict Keystone KSTAW141 disassembly?
Always shut off the electrical breaker and water shutoff valve before opening KSTAW141 service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.
How should owners confirm cutout clearance for Keystone KSTAW141?
Verify width, height, and depth against 21.7 × 14.7 × 19.0 in, leaving extra rear space for cords, hoses, or condenser airflow.
Where is the serial tag located on Keystone KSTAW141?
Inspect the inner liner wall, door rim, or tub flange via the Keystone serial guide to decode build month and year before buying replacement assemblies.
Related guides
Sources
- ENERGY STAR Certified Room Air Conditioners Dataset (5xn2-dv4h) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
- Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)
- CPSC Recalls REST Web Services API (SaferProducts.gov) — U.S. Consumer Product Safety Commission (CPSC), REST JSON 2026 (retrieved 2026-11-23)