Midea MAW08U2QWT Room Air Conditioner Specs
Verified EPA ENERGY STAR test logs for Midea MAW08U2QWT list 375 kWh/yr ($68.10/yr at 18.16c/kWh) and 8000.0 BTU/hr, giving this top-quartile efficiency Window unit clear cost separation at -157 kWh/yr (-29.5%) relative to the 531.9 kWh/yr median. Built into an 18-inch compact alcove, the assembly covers single SKU MAW08U2QWT. Cumulative power cost runs $681.00 over a 10-year NAHB lifespan while holding 47% below limit vs 10 CFR 430.
- Rated Energy
- 375 kWh/yr
- EIA Annual Cost
- $68.10/yr
- Category Rank
- #47 of 560
- Capacity
- 8000.0 BTU/hr
- NAHB Lifespan
- 10 years
How does MAW08U2QWT compare across all 560 room air conditioners?
Midea MAW08U2QWT (375 kWh/yr) sits against the room air conditioners category median of 531.9 kWh/yr, -157 kWh/yr (-29.5%), and U.S. 10 CFR 430 baselines.
View quantile summary for Room Air Conditioners — MAW08U2QWT
| Quantile / Marker | Annual kWh/yr |
|---|---|
| Most efficient model | 260.4 kWh/yr kWh |
| 25th percentile | 404.8 kWh/yr kWh |
| Category median | 531.9 kWh/yr kWh |
| 75th percentile | 647.5 kWh/yr kWh |
| Highest rated draw | 2096.3 kWh/yr kWh |
Where does MAW08U2QWT rank in operating-cost percentile?
Ranked #47 of 560 rated room air conditioners using EIA August 2026 national residential electricity rates (18.16 cents/kWh) over a 10-year NAHB median lifespan.
What are the official specs and computed benchmarks for Midea MAW08U2QWT?
Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (10 years), and estimated operating electricity costs at 18.16 cents/kWh.
| Specification / Metric | MAW08U2QWT Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| Rated Energy | 375 kWh/yr [U.S. Environmental Protection Agency (ENERGY STAR)] | Median 532 kWh/yr | Tied with 23 peers at 375 kWh/yr (-157 kWh/yr, -29.5% vs median) |
| Capacity | 8000.0 BTU/hr [U.S. Environmental Protection Agency (ENERGY STAR)] | Standard BTU/hr rating | 0.05 kWh/BTU/hr (matches 0.05 median) |
| Cutout W × H × D | 19.2 × 13.5 × 22.0 in [U.S. Environmental Protection Agency (ENERGY STAR)] | Released 2024 | Single model listing (1 SKU) |
| Operating Cost (EIA) | $68.10/yr [U.S. Energy Information Administration (EIA)] | 18.16 c/kWh US avg | Formula: 375 kWh × $0.1816 = $68.10/yr ($681.00 over 10 yrs) |
| NAHB Service Life | 10 years [National Association of Home Builders (NAHB)] | 50% age gate: 5.0 yrs | Evaluate repair vs net replacement once age passes 6.5 yrs |
| CEER | 16.0 BTU/Wh | 115 | Certified efficiency metric |
Which room air conditioners match MAW08U2QWT in cutout width and energy draw?
Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.
| Peer Model | Subtype | kWh/yr | Delta vs MAW08U2QWT | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| BLACK+DECKER BDM08 | Window | 375 | Same kWh | 8000.0 BTU/hr | 19.0 × 13.6 × 18.5 in | 1 |
| DuraSTAR DRWAC081XVB1 | Window | 375 | Same kWh | 8000.0 BTU/hr | 19.0 × 13.6 × 18.5 in | 1 |
| Frigidaire FHWW085WF1 | Window | 375 | Same kWh | 8000.0 BTU/hr | 19.0 × 13.6 × 18.5 in | 1 |
| GE PWJV08 | Window | 375 | Same kWh | 8000.0 BTU/hr | 18.6 × 12.6 × 15.3 in | 1 |
| TCL T08WV3 | Window | 375 | Same kWh | 8000.0 BTU/hr | 18.6 × 13.3 × 17.7 in | 1 |
Does MAW08U2QWT carry R-600a, duct, or installation boundaries?
MAW08U2QWT (Window, 19.2 in width, CEER 16.0) cools matched room square footage efficiently using R-32 refrigerant.
Sealed refrigerant lines (R-32) are non-serviceable for DIY; keep washable intake filters and outdoor condenser fins clean every 30 days.
- MAW08U2QWT
Should you repair MAW08U2QWT or replace it under the 50% rule?
Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.
FAQ
Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.
How much does running Midea MAW08U2QWT cost each year?
At 18.16 cents/kWh (EIA August 2026), Midea MAW08U2QWT draws 375 kWh/yr, equating to $68.10/yr ($681 over 10 years) across all 1 finish trim, specifically MAW08U2QWT.
How efficient is Midea MAW08U2QWT compared with federal ceilings?
Measured against 10 CFR 430 certified, Midea MAW08U2QWT holds rank #47 out of 560 U.S. ENERGY STAR room air conditioners: -157 kWh/yr (-29.5%) vs median 531.9 kWh/yr.
Which minor parts are exceptions to replacing Midea MAW08U2QWT?
Routine wear items such as gaskets, lint filters, coin traps, or inlet mesh remain worthwhile past 5.0 years, whereas motor or board quotes above 50% net replacement favor replacement.
When is Midea MAW08U2QWT a poor match for a remodel?
Avoid Midea MAW08U2QWT if 8000.0 BTU/hr falls short of household demand, if hookups conflict with 19.2 × 13.5 × 22.0 in, or if local electricity tariffs justify the lowest-kWh quartile.
Do all variants in the Midea MAW08U2QWT line use identical energy?
Yes; every listed finish — including MAW08U2QWT — shares the identical 375 kWh/yr ENERGY STAR test rating and 8000.0 BTU/hr volume.
What safety codes restrict Midea MAW08U2QWT disassembly?
Always shut off the electrical breaker and water shutoff valve before opening MAW08U2QWT service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.
How should owners confirm cutout clearance for Midea MAW08U2QWT?
Verify width, height, and depth against 19.2 × 13.5 × 22.0 in, leaving extra rear space for cords, hoses, or condenser airflow.
Where is the serial tag located on Midea MAW08U2QWT?
Inspect the inner liner wall, door rim, or tub flange via the Midea serial guide to decode build month and year before buying replacement assemblies.
Related guides
Sources
- ENERGY STAR Certified Room Air Conditioners Dataset (5xn2-dv4h) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
- Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)