Midea MAW08V1YWT- Room Air Conditioner Specs
Specified at 8000.0 BTU/hr and 400 kWh/yr ($72.64/yr at 18.16c/kWh), Midea MAW08V1YWT- #85 / 560 — tied with 51 peers, uses less energy than 75.7% of 560 room air conditioners in the U.S. ENERGY STAR directory. Shared internal engineering unites single SKU MAW08V1YWT-S within an 18-inch compact alcove. Evaluated over a 10-year NAHB benchmark service window, operating power equals $726.40 over a 10-year NAHB lifespan with 38% below limit margin under DOE 10 CFR 430.
- Rated Energy
- 400 kWh/yr
- EIA Annual Cost
- $72.64/yr
- Category Rank
- #85 of 560
- Capacity
- 8000.0 BTU/hr
- NAHB Lifespan
- 10 years
How does MAW08V1YWT- compare across all 560 room air conditioners?
Midea MAW08V1YWT- (400 kWh/yr) sits against the room air conditioners category median of 531.9 kWh/yr, -132 kWh/yr (-24.8%), and U.S. 10 CFR 430 baselines.
View quantile summary for Room Air Conditioners — MAW08V1YWT-
| Quantile / Marker | Annual kWh/yr |
|---|---|
| Most efficient model | 260.4 kWh/yr kWh |
| 25th percentile | 404.8 kWh/yr kWh |
| Category median | 531.9 kWh/yr kWh |
| 75th percentile | 647.5 kWh/yr kWh |
| Highest rated draw | 2096.3 kWh/yr kWh |
Where does MAW08V1YWT- rank in operating-cost percentile?
Ranked #85 of 560 rated room air conditioners using EIA August 2026 national residential electricity rates (18.16 cents/kWh) over a 10-year NAHB median lifespan.
What are the official specs and computed benchmarks for Midea MAW08V1YWT-?
Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (10 years), and estimated operating electricity costs at 18.16 cents/kWh.
| Specification / Metric | MAW08V1YWT- Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| Rated Energy | 400 kWh/yr [U.S. Environmental Protection Agency (ENERGY STAR)] | Median 532 kWh/yr | Tied with 51 peers at 400 kWh/yr (-132 kWh/yr, -24.8% vs median) |
| Capacity | 8000.0 BTU/hr [U.S. Environmental Protection Agency (ENERGY STAR)] | Standard BTU/hr rating | 0.05 kWh/BTU/hr (matches 0.05 median) |
| Cutout W × H × D | 19.2 × 13.5 × 22.0 in [U.S. Environmental Protection Agency (ENERGY STAR)] | Released 2024 | Single model listing (1 SKU) |
| Operating Cost (EIA) | $72.64/yr [U.S. Energy Information Administration (EIA)] | 18.16 c/kWh US avg | Formula: 400 kWh × $0.1816 = $72.64/yr ($726.40 over 10 yrs) |
| NAHB Service Life | 10 years [National Association of Home Builders (NAHB)] | 50% age gate: 5.0 yrs | Evaluate repair vs net replacement once age passes 6.5 yrs |
| CEER | 15.0 BTU/Wh | 115 | Certified efficiency metric |
Which room air conditioners match MAW08V1YWT- in cutout width and energy draw?
Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.
| Peer Model | Subtype | kWh/yr | Delta vs MAW08V1YWT- | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| Century RXTS-81 | Window | 400 | Same kWh | 8000.0 BTU/hr | 19.2 × 13.5 × 22.0 in | 1 |
| Comfort Aire RXTS-81 | Window | 400 | Same kWh | 8000.0 BTU/hr | 19.2 × 13.5 × 22.0 in | 1 |
| Danby DAC080B7IWDB-6 | Window | 400 | Same kWh | 8000.0 BTU/hr | 19.2 × 13.5 × 22.0 in | 1 |
| Danby DAC080B8IWDB-6 | Window | 400 | Same kWh | 8000.0 BTU/hr | 19.2 × 13.5 × 22.0 in | 1 |
| Frigidaire Gallery GHWQ083WC1 | Window | 400 | Same kWh | 8000.0 BTU/hr | 19.2 × 13.5 × 22.0 in | 1 |
Does MAW08V1YWT- carry R-600a, duct, or installation boundaries?
MAW08V1YWT- (Window, 19.2 in width, CEER 15.0) cools matched room square footage efficiently using R-32 refrigerant.
Sealed refrigerant lines (R-32) are non-serviceable for DIY; keep washable intake filters and outdoor condenser fins clean every 30 days.
- MAW08V1YWT-S
Should you repair MAW08V1YWT- or replace it under the 50% rule?
Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.
FAQ
Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.
How much electricity does the Midea MAW08V1YWT- draw each year?
EPA ENERGY STAR lists Midea MAW08V1YWT- at 400 kWh/yr, producing an estimated utility outlay of $72.64/yr ($726 over 10 years) at the U.S. EIA residential benchmark of 18.16 cents/kWh across 1 finish SKUs.
How does Midea MAW08V1YWT- compare against the federal limit?
Against the 10 CFR 430 certified, this Midea room air conditioner ranks #85 among 560 certified room air conditioners — -132 kWh/yr (-24.8%) vs the 531.9 kWh/yr median.
When is repairing Midea MAW08V1YWT- out of warranty NOT worthwhile?
Avoid major mechanical or control-board repairs once Midea MAW08V1YWT- passes 5.0 years (half its 10-year NAHB lifespan) or whenever a technician quote reaches 50% of net replacement cost.
Who should NOT install the Midea MAW08V1YWT- room air conditioner?
Do not specify Midea MAW08V1YWT- (8000.0 BTU/hr) for commercial duty cycles, tight alcoves that cannot clear 19.2 × 13.5 × 22.0 in plus ventilation gaps, or inside an active year-1 manufacturer warranty period.
Which SKU trims map to the Midea MAW08V1YWT- appliance models?
CodeBench merges 1 finish code, led by MAW08V1YWT-S, under MAW08V1YWT- because color suffixes share identical core power draw, 8000.0 BTU/hr volume, and outer cabinet dimensions.
What safety rules govern Midea MAW08V1YWT- repairs?
Always shut off the electrical breaker and water shutoff valve before opening MAW08V1YWT- service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.
How do 5 peer alternatives match up to Midea MAW08V1YWT-?
The peer table compares 5 room air conditioners selected closest to MAW08V1YWT- by cutout width, 8000.0 BTU/hr capacity, and 400 kWh/yr rating so homeowners can evaluate direct drop-in replacements.
How do you verify the build age of Midea MAW08V1YWT-?
Check the interior serial sticker with the Midea serial date guide rather than relying only on the 2024 catalog release year, especially when 10-year codes repeat.
Related guides
Sources
- ENERGY STAR Certified Room Air Conditioners Dataset (5xn2-dv4h) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
- Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)