Verdant ZX-TW- Smart Thermostat Specs
Designed for a standard residential footprint at 0.18 deg F acc, Verdant ZX-TW- draws Standby Draw 0.83 W and ranks +0.2 W (+43.1%) relative to the 0.6 W median among 118 certified smart thermostats. Factory color variants map back to single SKU ZX-TW-*. Pairing ENERGY STAR certified DOE 10 CFR 430 compliance with NAHB median expectancy points to rated service expectations across a 12-year NAHB lifespan.
- Rated Energy
- Smart Thermostats
- EIA Annual Cost
- Not listed
- Category Rank
- #48 of 118
- Capacity
- 0.18 deg F acc
- NAHB Lifespan
- 12 years
What are the official specs and computed benchmarks for Verdant ZX-TW-?
Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (12 years), and estimated operating electricity costs at 18.16 cents/kWh.
| Specification / Metric | ZX-TW- Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| Capacity | 0.18 deg F acc [U.S. Environmental Protection Agency (ENERGY STAR)] | Standard deg F acc rating | Density unavailable |
| Listing & Release | Released 2022 | 1 SKU | Single model listing (1 SKU) |
| NAHB Service Life | 12 years [National Association of Home Builders (NAHB)] | 50% age gate: 6.0 yrs | Evaluate repair vs net replacement once age passes 7.8 yrs |
| Standby Draw | 0.83 W | ENERGY STAR certified | Certified efficiency metric |
Which smart thermostats match ZX-TW- in cutout width and energy draw?
Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.
| Peer Model | Subtype | kWh/yr | Delta vs ZX-TW- | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| Amazon S6ED3R | Smart Thermostats | Not listed | Not listed | 0.31 deg F acc | Not listed | 1 |
| TCC TH9320 | Smart Thermostats | Not listed | Not listed | 0.37 deg F acc | Not listed | 1 |
| Bryant T6-WEM01- | Smart Thermostats | Not listed | Not listed | 0.45 deg F acc | Not listed | 1 |
| Carrier TP-WEM01- | Smart Thermostats | Not listed | Not listed | 0.45 deg F acc | Not listed | 1 |
| Ecobee EB-STATE3LT***- | Smart Thermostats | Not listed | Not listed | 0.45 deg F acc | Not listed | 1 |
Does ZX-TW- carry R-600a, duct, or installation boundaries?
ZX-TW- (Connected Smart Thermostat) manages 24VAC HVAC staging and setback schedules; verify C-wire common availability before mounting.
Turn off 24VAC furnace/air-handler breaker before moving R/C/W/Y/G thermostat conductors to avoid blowing the 3A-5A low-voltage control board fuse.
- ZX-TW-*
Should you repair ZX-TW- or replace it under the 50% rule?
Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.
FAQ
Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.
What annual electricity outlay should Verdant ZX-TW- owners budget?
Rated at certified ENERGY STAR status, Verdant ZX-TW- averages scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) under EIA's 18.16 cents/kWh U.S. average over 12 years of NAHB service life.
Where does Verdant ZX-TW- sit among 118 certified peers?
Out of 118 U.S. certified smart thermostats, Verdant ZX-TW- ranks #48 — Rank #48 / 118 (top 40.7%) — against 10 CFR 430 certified.
Should owners repair a failing Verdant ZX-TW- past 12 years?
NAHB places median smart thermostat service life at 12 years; past 6.0 years, estimates exceeding 50% of net new price (after $150 5-yr savings) favor replacement.
Who is Verdant ZX-TW- NOT designed for?
Commercial establishments, alcoves smaller than OEM cutout blueprint, and households requiring different capacity than 0.18 deg F acc should review peer alternatives above.
Which model numbers belong to the Verdant ZX-TW- platform?
All 1 finish code maps to the identical ZX-TW- platform, notably ZX-TW-*: certified ENERGY STAR status vs 0.0 kWh/yr category median.
What safety checks precede opening Verdant ZX-TW- housings?
Always shut off the electrical breaker and water shutoff valve before opening ZX-TW- service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.
How does Verdant ZX-TW- fit standard residential cutouts?
Measuring OEM cutout blueprint at 0.18 deg F acc, ZX-TW- aligns closely with the 5 nearest peer smart thermostats ranked in the alternative table above.
Can you date Verdant ZX-TW- if purchase paperwork is missing?
Yes; check the cabinet serial tag in our Verdant serial decoder to confirm manufacture year and out-of-warranty status.
Related guides
Sources
- ENERGY STAR Certified Smart Thermostats Dataset (7p2p-wkbf) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
- Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)