ACIQ AEP80 Ventilating Fan Specs
Specified at 80.0 CFM and Fan Efficacy 4.2 CFM/W, ACIQ AEP80 #607 / 900 — tied with 33 peers, scores higher efficiency than 28.9% of 900 ventilating fans in the U.S. ENERGY STAR directory. Shared internal engineering unites single SKU AEP80 within a standard residential footprint. Evaluated over a 15-year NAHB benchmark service window, operating power equals rated service expectations across a 15-year NAHB lifespan with ENERGY STAR certified margin under DOE 10 CFR 430.
- Rated Energy
- Ventilating Fans
- EIA Annual Cost
- Not listed
- Category Rank
- #607 of 900
- Capacity
- 80.0 CFM
- NAHB Lifespan
- 15 years
What are the official specs and computed benchmarks for ACIQ AEP80?
Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.
| Specification / Metric | AEP80 Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| Capacity | 80.0 CFM [U.S. Environmental Protection Agency (ENERGY STAR)] | Standard CFM rating | Density unavailable |
| Listing & Release | Released 2024 | 1 SKU | Single model listing (1 SKU) |
| NAHB Service Life | 15 years [National Association of Home Builders (NAHB)] | 50% age gate: 7.5 yrs | Evaluate repair vs net replacement once age passes 9.8 yrs |
| Fan Efficacy | 4.2 CFM/W | Bathroom/Utility Room | 6.00 inch diameter |
Which ventilating fans match AEP80 in cutout width and energy draw?
Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.
| Peer Model | Subtype | kWh/yr | Delta vs AEP80 | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| Canarm CEP80 | Bathroom/Utility Room | Not listed | Not listed | 80.0 CFM | Not listed | 1 |
| HomeWerks Worldwide 7130-19-BT | Bathroom/Utility Room | Not listed | Not listed | 80.0 CFM | Not listed | 1 |
| Revent RVM80 | Bathroom/Utility Room | Not listed | Not listed | 80.0 CFM | Not listed | 1 |
| Revent RVPR80 | Bathroom/Utility Room | Not listed | Not listed | 80.0 CFM | Not listed | 1 |
| Air King AK80 | Bathroom/Utility Room | Not listed | Not listed | 80.0 CFM | Not listed | 1 |
Does AEP80 carry R-600a, duct, or installation boundaries?
AEP80 (Bathroom/Utility Room, 4.2 CFM/W) vents humid indoor air outdoors via 6.00 inch diameter (never terminate into an enclosed attic).
Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.
- AEP80
Should you repair AEP80 or replace it under the 50% rule?
Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.
FAQ
Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.
What does ACIQ AEP80 consume in kWh and dollars?
EPA data records certified ENERGY STAR status for ACIQ AEP80, costing scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) at 18.16 cents/kWh across 1 consolidated SKU finishes.
How far below the federal ceiling is ACIQ AEP80?
It posts 10 CFR 430 certified and places #607 of 900 ventilating fans: -0.4 CFM/W (-8.7%) relative to the 0.0 kWh/yr median.
At what age does ACIQ AEP80 fail the 50% repair test?
Past 7.5 years of the 15-year NAHB benchmark, repair bids above half of net replacement minus $150 energy savings generally favor buying new.
Which buyers should skip ACIQ AEP80?
Skip AEP80 if cabinet openings cannot clear OEM cutout blueprint, if 80.0 CFM misses family sizing, or if commercial heavy-use durability is required.
Are AEP80 mechanically the same model?
Yes; cosmetic finish trims (1 total SKUs) share identical certified ENERGY STAR status efficiency, 80.0 CFM interior rating, and chassis assemblies.
Which safety boundaries restrict ACIQ AEP80 DIY work?
Always shut off the electrical breaker and water shutoff valve before opening AEP80 service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.
Which peer alternatives match ACIQ AEP80?
Review the 5 closest ventilating fans listed above, sorted by OEM cutout blueprint cutout, 80.0 CFM capacity, and annual kWh similarity.
What checks come before ordering ACIQ AEP80 replacement parts?
Decode the serial manufacture year, verify active ACIQ CPSC recalls, and test the repair quote in the 50% estimator above.
Related guides
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
- Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)