ACIQ ANP80 Ventilating Fan Specs
Designed for a standard residential footprint at 80.0 CFM, ACIQ ANP80 draws Fan Efficacy 4.9 CFM/W and ranks +0.3 CFM/W (+6.5%) relative to the 4.6 CFM/W median among 900 certified ventilating fans. Factory color variants map back to single SKU ANP80. Pairing ENERGY STAR certified DOE 10 CFR 430 compliance with NAHB median expectancy points to rated service expectations across a 15-year NAHB lifespan.
- Rated Energy
- Ventilating Fans
- EIA Annual Cost
- Not listed
- Category Rank
- #400 of 900
- Capacity
- 80.0 CFM
- NAHB Lifespan
- 15 years
What are the official specs and computed benchmarks for ACIQ ANP80?
Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.
| Specification / Metric | ANP80 Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| Capacity | 80.0 CFM [U.S. Environmental Protection Agency (ENERGY STAR)] | Standard CFM rating | Density unavailable |
| Listing & Release | Released 2024 | 1 SKU | Single model listing (1 SKU) |
| NAHB Service Life | 15 years [National Association of Home Builders (NAHB)] | 50% age gate: 7.5 yrs | Evaluate repair vs net replacement once age passes 9.8 yrs |
| Fan Efficacy | 4.9 CFM/W | Bathroom/Utility Room | 4.00 inch diameter |
Which ventilating fans match ANP80 in cutout width and energy draw?
Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.
| Peer Model | Subtype | kWh/yr | Delta vs ANP80 | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| Canarm CNP80 | Bathroom/Utility Room | Not listed | Not listed | 80.0 CFM | Not listed | 1 |
| Ortech ODC-8003 | Bathroom/Utility Room | Not listed | Not listed | 80.0 CFM | Not listed | 1 |
| QuFresh BC80 | Bathroom/Utility Room | Not listed | Not listed | 80.0 CFM | Not listed | 1 |
| Fantech SMPL80 (484300) | Bathroom/Utility Room | Not listed | Not listed | 80.0 CFM | Not listed | 1 |
| Fantech SMPL80L (484301) | Bathroom/Utility Room | Not listed | Not listed | 80.0 CFM | Not listed | 1 |
Does ANP80 carry R-600a, duct, or installation boundaries?
ANP80 (Bathroom/Utility Room, 4.9 CFM/W) vents humid indoor air outdoors via 4.00 inch diameter (never terminate into an enclosed attic).
Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.
- ANP80
Should you repair ANP80 or replace it under the 50% rule?
Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.
FAQ
Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.
How much does running ACIQ ANP80 cost each year?
At 18.16 cents/kWh (EIA August 2026), ACIQ ANP80 draws certified ENERGY STAR status, equating to scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) across all 1 finish trim, specifically ANP80.
How efficient is ACIQ ANP80 compared with federal ceilings?
Measured against 10 CFR 430 certified, ACIQ ANP80 holds rank #400 out of 900 U.S. ENERGY STAR ventilating fans: +0.3 CFM/W (+6.5%) vs median 0.0 kWh/yr.
Which minor parts are exceptions to replacing ACIQ ANP80?
Routine wear items such as gaskets, lint filters, coin traps, or inlet mesh remain worthwhile past 7.5 years, whereas motor or board quotes above 50% net replacement favor replacement.
When is ACIQ ANP80 a poor match for a remodel?
Avoid ACIQ ANP80 if 80.0 CFM falls short of household demand, if hookups conflict with OEM cutout blueprint, or if local electricity tariffs justify the lowest-kWh quartile.
Do all variants in the ACIQ ANP80 line use identical energy?
Yes; every listed finish — including ANP80 — shares the identical certified ENERGY STAR status ENERGY STAR test rating and 80.0 CFM volume.
What safety codes restrict ACIQ ANP80 disassembly?
Always shut off the electrical breaker and water shutoff valve before opening ANP80 service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.
How should owners confirm cutout clearance for ACIQ ANP80?
Verify width, height, and depth against OEM cutout blueprint, leaving extra rear space for cords, hoses, or condenser airflow.
Where is the serial tag located on ACIQ ANP80?
Inspect the inner liner wall, door rim, or tub flange via the ACIQ serial guide to decode build month and year before buying replacement assemblies.
Related guides
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
- Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)