Skip to main content
Ventilating Fans · Rank #529 of 900

AERO PURE ABF80L5OR Ventilating Fan Specs

Designed for a standard residential footprint at 80.0 CFM, AERO PURE ABF80L5OR draws Fan Efficacy 4.4 CFM/W and ranks -0.2 CFM/W (-4.3%) relative to the 4.6 CFM/W median among 900 certified ventilating fans. Factory color variants map back to single SKU ABF80L5OR. Pairing ENERGY STAR certified DOE 10 CFR 430 compliance with NAHB median expectancy points to rated service expectations across a 15-year NAHB lifespan.

Rated Energy
Ventilating Fans
EIA Annual Cost
Not listed
Category Rank
#529 of 900
Capacity
80.0 CFM
NAHB Lifespan
15 years
Annual Energy Draw Certified Rank #529 / 900 (tied with 32 at 4.4 CFM/W)
vs Ventilating Fans Median -0.2 CFM/W (-4.3%) EPA certified comparison
Federal Metric (Fan Efficacy) 4.4 CFM/W 10 CFR 430 certified
Est. Operating Cost Unrated Annual kWh not listed

What are the official specs and computed benchmarks for AERO PURE ABF80L5OR?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.

AERO PURE ABF80L5OR — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)
Specification / Metric ABF80L5OR Value Category / Federal Benchmark Computed Insight & Formula
Capacity 80.0 CFM [U.S. Environmental Protection Agency (ENERGY STAR)] Standard CFM rating Density unavailable
Listing & Release Released 2025 1 SKU Single model listing (1 SKU)
NAHB Service Life 15 years [National Association of Home Builders (NAHB)] 50% age gate: 7.5 yrs Evaluate repair vs net replacement once age passes 9.8 yrs
Fan Efficacy 4.4 CFM/W Bathroom/Utility Room 4.00 inch diameter

Which ventilating fans match ABF80L5OR in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Ventilating Fans (Matched by Width & kWh Draw)
Peer Model Subtype kWh/yr Delta vs ABF80L5OR Capacity Cutout Dimensions SKUs
Dayton 1UBH7 Bathroom/Utility Room Not listed Not listed 80.0 CFM Not listed 1
Greenheck SP-B80 Bathroom/Utility Room Not listed Not listed 80.0 CFM Not listed 1
Air King AK80LS Bathroom/Utility Room Not listed Not listed 80.0 CFM Not listed 1
Tech Drive TD-BF-04-PLU Bathroom/Utility Room Not listed Not listed 80.0 CFM Not listed 1
VENTECHLATION VF-BF-03 Bathroom/Utility Room Not listed Not listed 80.0 CFM Not listed 1

Does ABF80L5OR carry R-600a, duct, or installation boundaries?

ABF80L5OR (Bathroom/Utility Room, 4.4 CFM/W) vents humid indoor air outdoors via 4.00 inch diameter (never terminate into an enclosed attic).

Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.

  • ABF80L5OR

Should you repair ABF80L5OR or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

What is the projected 15-year power cost for AERO PURE ABF80L5OR?

Multiplying certified ENERGY STAR status by the U.S. EIA residential average of 18.16 cents/kWh places AERO PURE ABF80L5OR running cost at scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) over its 15-year NAHB component life.

Does AERO PURE ABF80L5OR outperform the ventilating fans category median?

Against a category median of 0.0 kWh/yr across 900 chassis, AERO PURE ABF80L5OR stands at rank #529: -0.2 CFM/W (-4.3%); Rank #529 / 900 (tied with 32 at 4.4 CFM/W).

What is the 50% cost threshold for AERO PURE ABF80L5OR repairs?

Subtract eligible incentives and 5-year energy savings ($150) from replacement retail price, then cap repair quotes at 50% once age exceeds 7.5 years.

Which installations do NOT fit AERO PURE ABF80L5OR?

Skip AERO PURE ABF80L5OR if your cabinet cutout cannot fit OEM cutout blueprint, if 80.0 CFM cannot clear household doorways, or if commercial throughput exceeds residential engineering limits.

Why are 1 SKU variants grouped under AERO PURE ABF80L5OR?

Manufacturers file separate paint letters such as ABF80L5OR for one mechanical chassis; grouping them shows true certified ENERGY STAR status and 80.0 CFM specs without duplicate model clutter.

Which hazards forbid uncertified work on AERO PURE ABF80L5OR?

Always shut off the electrical breaker and water shutoff valve before opening ABF80L5OR service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

Can you swap AERO PURE ABF80L5OR without modifying kitchen framing?

Inspect the 5 nearest peers matched to OEM cutout blueprint and 80.0 CFM; selecting a peer matching ABF80L5OR's width avoids countertop or cabinet trim alterations.

Why screen recall notices for AERO PURE ABF80L5OR before paid service?

Active CPSC safety notices entitle owners to no-charge OEM remedies; always verify your exact serial number on CPSC recall bulletins before booking out-of-warranty work.

Related guides

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
  2. Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
  3. Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)