Ventilating Fans · Rank #491 of 900

Air King AK150L Ventilating Fan Specs

For out-of-warranty owners diagnosing Air King AK150L, EPA ENERGY STAR records Fan Efficacy 4.5 CFM/W and 150.0 CFM across single SKU AK150LS. This Bathroom/Utility Room appliance installs into a standard residential footprint and carries a 15-year NAHB median expectancy. Estimated cumulative utility draw reaches rated service expectations across a 15-year NAHB lifespan at EIA 18.16 cents/kWh, maintaining ENERGY STAR certified under 10 CFR 430.

Rated Energy
Ventilating Fans
EIA Annual Cost
Not listed
Category Rank
#491 of 900
Capacity
150.0 CFM
NAHB Lifespan
15 years
Annual Energy Draw Certified Rank #491 / 900 (tied with 37 at 4.5 CFM/W)
vs Ventilating Fans Median -0.1 CFM/W (-2.2%) EPA certified comparison
Federal Metric (Fan Efficacy) 4.5 CFM/W 10 CFR 430 certified
Est. Operating Cost Unrated Annual kWh not listed

What are the official specs and computed benchmarks for Air King AK150L?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.

Air King AK150L — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)
Specification / Metric AK150L Value Category / Federal Benchmark Computed Insight & Formula
Capacity 150.0 CFM [U.S. Environmental Protection Agency (ENERGY STAR)] Standard CFM rating Density unavailable
Listing & Release Released 2022 1 SKU Single model listing (1 SKU)
NAHB Service Life 15 years [National Association of Home Builders (NAHB)] 50% age gate: 7.5 yrs Evaluate repair vs net replacement once age passes 9.8 yrs
Fan Efficacy 4.5 CFM/W Bathroom/Utility Room 6.00 inch diameter

Which ventilating fans match AK150L in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Ventilating Fans (Matched by Width & kWh Draw)
Peer Model Subtype kWh/yr Delta vs AK150L Capacity Cutout Dimensions SKUs
Broan QT150L Bathroom/Utility Room Not listed Not listed 150.0 CFM Not listed 1
KOHLER 34455 Bathroom/Utility Room Not listed Not listed 150.0 CFM Not listed 2
KOHLER 34457 Bathroom/Utility Room Not listed Not listed 150.0 CFM Not listed 2
KOHLER K-34455 Bathroom/Utility Room Not listed Not listed 150.0 CFM Not listed 2
KOHLER K-34457 Bathroom/Utility Room Not listed Not listed 150.0 CFM Not listed 2

Does AK150L carry R-600a, duct, or installation boundaries?

AK150L (Bathroom/Utility Room, 4.5 CFM/W) vents humid indoor air outdoors via 6.00 inch diameter (never terminate into an enclosed attic).

Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.

  • AK150LS

Should you repair AK150L or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

What does Air King AK150L consume in kWh and dollars?

EPA data records certified ENERGY STAR status for Air King AK150L, costing scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) at 18.16 cents/kWh across 1 consolidated SKU finishes.

How far below the federal ceiling is Air King AK150L?

It posts 10 CFR 430 certified and places #491 of 900 ventilating fans: -0.1 CFM/W (-2.2%) relative to the 0.0 kWh/yr median.

At what age does Air King AK150L fail the 50% repair test?

Past 7.5 years of the 15-year NAHB benchmark, repair bids above half of net replacement minus $150 energy savings generally favor buying new.

Which buyers should skip Air King AK150L?

Skip AK150L if cabinet openings cannot clear OEM cutout blueprint, if 150.0 CFM misses family sizing, or if commercial heavy-use durability is required.

Are AK150LS mechanically the same model?

Yes; cosmetic finish trims (1 total SKUs) share identical certified ENERGY STAR status efficiency, 150.0 CFM interior rating, and chassis assemblies.

Which safety boundaries restrict Air King AK150L DIY work?

Always shut off the electrical breaker and water shutoff valve before opening AK150L service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

Which peer alternatives match Air King AK150L?

Review the 5 closest ventilating fans listed above, sorted by OEM cutout blueprint cutout, 150.0 CFM capacity, and annual kWh similarity.

What checks come before ordering Air King AK150L replacement parts?

Decode the serial manufacture year, verify active Air King CPSC recalls, and test the repair quote in the 50% estimator above.