AUPU BF6-11 Ventilating Fan Specs
Spanning single SKU BF6-11, AUPU BF6-11 logs Fan Efficacy 3.9 CFM/W inside a standard residential footprint built for 110.0 CFM. Out of 900 certified U.S. ventilating fans, this Bathroom/Utility Room model achieves higher-draw: #688 / 900 — tied with 51 peers, scores higher efficiency than 17.9% of 900 ventilating fans. Out-of-warranty owners weighing component quotes face rated service expectations across a 15-year NAHB lifespan and ENERGY STAR certified compliance under 10 CFR 430.
- Rated Energy
- Ventilating Fans
- EIA Annual Cost
- Not listed
- Category Rank
- #688 of 900
- Capacity
- 110.0 CFM
- NAHB Lifespan
- 15 years
What are the official specs and computed benchmarks for AUPU BF6-11?
Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.
| Specification / Metric | BF6-11 Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| Capacity | 110.0 CFM [U.S. Environmental Protection Agency (ENERGY STAR)] | Standard CFM rating | Density unavailable |
| Listing & Release | Released 2026 | 1 SKU | Single model listing (1 SKU) |
| NAHB Service Life | 15 years [National Association of Home Builders (NAHB)] | 50% age gate: 7.5 yrs | Evaluate repair vs net replacement once age passes 9.8 yrs |
| Fan Efficacy | 3.9 CFM/W | Bathroom/Utility Room | 4.00 inch diameter |
Which ventilating fans match BF6-11 in cutout width and energy draw?
Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.
| Peer Model | Subtype | kWh/yr | Delta vs BF6-11 | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| Air King AK110L | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 1 |
| Air King AK110LS6 | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 1 |
| Akicon AK15110N5- | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 3 |
| Commercial Electric 7130-20- | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 1 |
| Milano TY-110- | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 1 |
Does BF6-11 carry R-600a, duct, or installation boundaries?
BF6-11 (Bathroom/Utility Room, 3.9 CFM/W) vents humid indoor air outdoors via 4.00 inch diameter (never terminate into an enclosed attic).
Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.
- BF6-11
Should you repair BF6-11 or replace it under the 50% rule?
Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.
FAQ
Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.
How much does running AUPU BF6-11 cost each year?
At 18.16 cents/kWh (EIA August 2026), AUPU BF6-11 draws certified ENERGY STAR status, equating to scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) across all 1 finish trim, specifically BF6-11.
How efficient is AUPU BF6-11 compared with federal ceilings?
Measured against 10 CFR 430 certified, AUPU BF6-11 holds rank #688 out of 900 U.S. ENERGY STAR ventilating fans: -0.7 CFM/W (-15.2%) vs median 0.0 kWh/yr.
Which minor parts are exceptions to replacing AUPU BF6-11?
Routine wear items such as gaskets, lint filters, coin traps, or inlet mesh remain worthwhile past 7.5 years, whereas motor or board quotes above 50% net replacement favor replacement.
When is AUPU BF6-11 a poor match for a remodel?
Avoid AUPU BF6-11 if 110.0 CFM falls short of household demand, if hookups conflict with OEM cutout blueprint, or if local electricity tariffs justify the lowest-kWh quartile.
Do all variants in the AUPU BF6-11 line use identical energy?
Yes; every listed finish — including BF6-11 — shares the identical certified ENERGY STAR status ENERGY STAR test rating and 110.0 CFM volume.
What safety codes restrict AUPU BF6-11 disassembly?
Always shut off the electrical breaker and water shutoff valve before opening BF6-11 service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.
How should owners confirm cutout clearance for AUPU BF6-11?
Verify width, height, and depth against OEM cutout blueprint, leaving extra rear space for cords, hoses, or condenser airflow.
Where is the serial tag located on AUPU BF6-11?
Inspect the inner liner wall, door rim, or tub flange via the AUPU serial guide to decode build month and year before buying replacement assemblies.