Skip to main content
Ventilating Fans · Rank #151 of 900

AUPU BF6-S13 Ventilating Fan Specs

Designed for a standard residential footprint at 110.0 CFM, AUPU BF6-S13 draws Fan Efficacy 9.7 CFM/W and ranks +5.1 CFM/W (+110.9%) relative to the 4.6 CFM/W median among 900 certified ventilating fans. Factory color variants map back to single SKU BF6-S13C. Pairing ENERGY STAR certified DOE 10 CFR 430 compliance with NAHB median expectancy points to rated service expectations across a 15-year NAHB lifespan.

Rated Energy
Ventilating Fans
EIA Annual Cost
Not listed
Category Rank
#151 of 900
Capacity
110.0 CFM
NAHB Lifespan
15 years
Annual Energy Draw Certified Rank #151 / 900 (top 17.1%)
vs Ventilating Fans Median +5.1 CFM/W (+110.9%) EPA certified comparison
Federal Metric (Fan Efficacy) 9.7 CFM/W 10 CFR 430 certified
Est. Operating Cost Unrated Annual kWh not listed

What are the official specs and computed benchmarks for AUPU BF6-S13?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.

AUPU BF6-S13 — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)
Specification / Metric BF6-S13 Value Category / Federal Benchmark Computed Insight & Formula
Capacity 110.0 CFM [U.S. Environmental Protection Agency (ENERGY STAR)] Standard CFM rating Density unavailable
Listing & Release Released 2026 1 SKU Single model listing (1 SKU)
NAHB Service Life 15 years [National Association of Home Builders (NAHB)] 50% age gate: 7.5 yrs Evaluate repair vs net replacement once age passes 9.8 yrs
Fan Efficacy 9.7 CFM/W Bathroom/Utility Room 4.00 inch diameter

Which ventilating fans match BF6-S13 in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Ventilating Fans (Matched by Width & kWh Draw)
Peer Model Subtype kWh/yr Delta vs BF6-S13 Capacity Cutout Dimensions SKUs
Broan AE50110 Bathroom/Utility Room Not listed Not listed 110.0 CFM Not listed 2
Broan AE50110DC = A000HFKT WITH AE50110DCF Bathroom/Utility Room Not listed Not listed 110.0 CFM Not listed 1
Broan AE50110DC = A000HFKTC WITH AE50110DCF Bathroom/Utility Room Not listed Not listed 110.0 CFM Not listed 1
Broan AE50110DC = A000HFNF WITH AE50110DCF Bathroom/Utility Room Not listed Not listed 110.0 CFM Not listed 1
Broan AE50110DCL Bathroom/Utility Room Not listed Not listed 110.0 CFM Not listed 1

Does BF6-S13 carry R-600a, duct, or installation boundaries?

BF6-S13 (Bathroom/Utility Room, 9.7 CFM/W) vents humid indoor air outdoors via 4.00 inch diameter (never terminate into an enclosed attic).

Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.

  • BF6-S13C

Should you repair BF6-S13 or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

What does AUPU BF6-S13 consume in kWh and dollars?

EPA data records certified ENERGY STAR status for AUPU BF6-S13, costing scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) at 18.16 cents/kWh across 1 consolidated SKU finishes.

How far below the federal ceiling is AUPU BF6-S13?

It posts 10 CFR 430 certified and places #151 of 900 ventilating fans: +5.1 CFM/W (+110.9%) relative to the 0.0 kWh/yr median.

At what age does AUPU BF6-S13 fail the 50% repair test?

Past 7.5 years of the 15-year NAHB benchmark, repair bids above half of net replacement minus $150 energy savings generally favor buying new.

Which buyers should skip AUPU BF6-S13?

Skip BF6-S13 if cabinet openings cannot clear OEM cutout blueprint, if 110.0 CFM misses family sizing, or if commercial heavy-use durability is required.

Are BF6-S13C mechanically the same model?

Yes; cosmetic finish trims (1 total SKUs) share identical certified ENERGY STAR status efficiency, 110.0 CFM interior rating, and chassis assemblies.

Which safety boundaries restrict AUPU BF6-S13 DIY work?

Always shut off the electrical breaker and water shutoff valve before opening BF6-S13 service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

Which peer alternatives match AUPU BF6-S13?

Review the 5 closest ventilating fans listed above, sorted by OEM cutout blueprint cutout, 110.0 CFM capacity, and annual kWh similarity.

What checks come before ordering AUPU BF6-S13 replacement parts?

Decode the serial manufacture year, verify active AUPU CPSC recalls, and test the repair quote in the 50% estimator above.

Related guides

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
  2. Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
  3. Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)