Verified EPA ENERGY STAR test logs for Broan 744FL list Fan Efficacy 4 CFM/W and 70.0 CFM, giving this higher-draw Bathroom/Utility Room unit clear cost separation at -0.6 CFM/W (-13.0%) relative to the 4.6 CFM/W median. Built into a standard residential footprint, the assembly covers single SKU 744FL. Cumulative power cost runs rated service expectations across a 15-year NAHB lifespan while holding ENERGY STAR certified vs 10 CFR 430.

Rated Energy
Ventilating Fans
EIA Annual Cost
Not listed
Category Rank
#663 of 900
Capacity
70.0 CFM
NAHB Lifespan
15 years
Annual Energy Draw Certified Rank #663 / 900 (tied with 24 at 4 CFM/W)
vs Ventilating Fans Median -0.6 CFM/W (-13.0%) EPA certified comparison
Federal Metric (Fan Efficacy) 4.0 CFM/W 10 CFR 430 certified
Est. Operating Cost Unrated Annual kWh not listed

What are the official specs and computed benchmarks for Broan 744FL?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.

Broan 744FL — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)
Specification / Metric 744FL Value Category / Federal Benchmark Computed Insight & Formula
Capacity 70.0 CFM [U.S. Environmental Protection Agency (ENERGY STAR)] Standard CFM rating Density unavailable
Listing & Release Released 2015 1 SKU Single model listing (1 SKU)
NAHB Service Life 15 years [National Association of Home Builders (NAHB)] 50% age gate: 7.5 yrs Evaluate repair vs net replacement once age passes 9.8 yrs
Fan Efficacy 4.0 CFM/W Bathroom/Utility Room 4 inch diameter

Which ventilating fans match 744FL in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Ventilating Fans (Matched by Width & kWh Draw)
Peer Model Subtype kWh/yr Delta vs 744FL Capacity Cutout Dimensions SKUs
Tech Drive FA-BF-02-L Bathroom/Utility Room Not listed Not listed 70.0 CFM Not listed 1
HomeWerks Worldwide 299650 Bathroom/Utility Room Not listed Not listed 70.0 CFM Not listed 1
Broan 744 Bathroom/Utility Room Not listed Not listed 70.0 CFM Not listed 1
Broan 744LED Bathroom/Utility Room Not listed Not listed 70.0 CFM Not listed 1
Broan BEL7A Bathroom/Utility Room Not listed Not listed 70.0 CFM Not listed 1

Does 744FL carry R-600a, duct, or installation boundaries?

744FL (Bathroom/Utility Room, 4.0 CFM/W) vents humid indoor air outdoors via 4 inch diameter (never terminate into an enclosed attic).

Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.

  • 744FL

Should you repair 744FL or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

What does Broan 744FL consume in kWh and dollars?

EPA data records certified ENERGY STAR status for Broan 744FL, costing scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) at 18.16 cents/kWh across 1 consolidated SKU finishes.

How far below the federal ceiling is Broan 744FL?

It posts 10 CFR 430 certified and places #663 of 900 ventilating fans: -0.6 CFM/W (-13.0%) relative to the 0.0 kWh/yr median.

At what age does Broan 744FL fail the 50% repair test?

Past 7.5 years of the 15-year NAHB benchmark, repair bids above half of net replacement minus $150 energy savings generally favor buying new.

Which buyers should skip Broan 744FL?

Skip 744FL if cabinet openings cannot clear OEM cutout blueprint, if 70.0 CFM misses family sizing, or if commercial heavy-use durability is required.

Are 744FL mechanically the same model?

Yes; cosmetic finish trims (1 total SKUs) share identical certified ENERGY STAR status efficiency, 70.0 CFM interior rating, and chassis assemblies.

Which safety boundaries restrict Broan 744FL DIY work?

Always shut off the electrical breaker and water shutoff valve before opening 744FL service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

Which peer alternatives match Broan 744FL?

Review the 5 closest ventilating fans listed above, sorted by OEM cutout blueprint cutout, 70.0 CFM capacity, and annual kWh similarity.

What checks come before ordering Broan 744FL replacement parts?

Decode the serial manufacture year, verify active Broan CPSC recalls, and test the repair quote in the 50% estimator above.

Related guides

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
  2. Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
  3. Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)