Skip to main content
Ventilating Fans · Rank #562 of 900

Broan AER110 Ventilating Fan Specs

Spanning 2 finish SKUs including AER110K, AER110S, Broan AER110 logs Fan Efficacy 4.3 CFM/W inside a standard residential footprint built for 110.0 CFM. Out of 900 certified U.S. ventilating fans, this Bathroom/Utility Room model achieves higher-draw: #562 / 900 — tied with 44 peers, scores higher efficiency than 32.7% of 900 ventilating fans. Out-of-warranty owners weighing component quotes face rated service expectations across a 15-year NAHB lifespan and ENERGY STAR certified compliance under 10 CFR 430.

Rated Energy
Ventilating Fans
EIA Annual Cost
Not listed
Category Rank
#562 of 900
Capacity
110.0 CFM
NAHB Lifespan
15 years
Annual Energy Draw Certified Rank #562 / 900 (tied with 44 at 4.3 CFM/W)
vs Ventilating Fans Median -0.3 CFM/W (-6.5%) EPA certified comparison
Federal Metric (Fan Efficacy) 4.3 CFM/W 10 CFR 430 certified
Est. Operating Cost Unrated Annual kWh not listed

What are the official specs and computed benchmarks for Broan AER110?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.

Broan AER110 — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)
Specification / Metric AER110 Value Category / Federal Benchmark Computed Insight & Formula
Capacity 110.0 CFM [U.S. Environmental Protection Agency (ENERGY STAR)] Standard CFM rating Density unavailable
Listing & Release Released 2026 2 SKUs Consolidates 2 finish variants
NAHB Service Life 15 years [National Association of Home Builders (NAHB)] 50% age gate: 7.5 yrs Evaluate repair vs net replacement once age passes 9.8 yrs
Fan Efficacy 4.3 CFM/W Bathroom/Utility Room 4.00 inch diameter

Which ventilating fans match AER110 in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Ventilating Fans (Matched by Width & kWh Draw)
Peer Model Subtype kWh/yr Delta vs AER110 Capacity Cutout Dimensions SKUs
Anzzi EF-AZ102 Bathroom/Utility Room Not listed Not listed 110.0 CFM Not listed 1
Commercial Electric BF1107 Bathroom/Utility Room Not listed Not listed 110.0 CFM Not listed 1
Commercial Electric BPT14-24OD- Bathroom/Utility Room Not listed Not listed 110.0 CFM Not listed 1
COSTWAY BPT14-24A-A-1 Bathroom/Utility Room Not listed Not listed 110.0 CFM Not listed 1
Nutone 791LEDNTM Bathroom/Utility Room Not listed Not listed 110.0 CFM Not listed 1

Does AER110 carry R-600a, duct, or installation boundaries?

AER110 (Bathroom/Utility Room, 4.3 CFM/W) vents humid indoor air outdoors via 4.00 inch diameter (never terminate into an enclosed attic).

Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.

  • AER110K
  • AER110S

Should you repair AER110 or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

How much does running Broan AER110 cost each year?

At 18.16 cents/kWh (EIA August 2026), Broan AER110 draws certified ENERGY STAR status, equating to scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) across all 2 finish trims, specifically AER110K, AER110S.

How efficient is Broan AER110 compared with federal ceilings?

Measured against 10 CFR 430 certified, Broan AER110 holds rank #562 out of 900 U.S. ENERGY STAR ventilating fans: -0.3 CFM/W (-6.5%) vs median 0.0 kWh/yr.

Which minor parts are exceptions to replacing Broan AER110?

Routine wear items such as gaskets, lint filters, coin traps, or inlet mesh remain worthwhile past 7.5 years, whereas motor or board quotes above 50% net replacement favor replacement.

When is Broan AER110 a poor match for a remodel?

Avoid Broan AER110 if 110.0 CFM falls short of household demand, if hookups conflict with OEM cutout blueprint, or if local electricity tariffs justify the lowest-kWh quartile.

Do all variants in the Broan AER110 line use identical energy?

Yes; every listed finish — including AER110K, AER110S — shares the identical certified ENERGY STAR status ENERGY STAR test rating and 110.0 CFM volume.

What safety codes restrict Broan AER110 disassembly?

Always shut off the electrical breaker and water shutoff valve before opening AER110 service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

How should owners confirm cutout clearance for Broan AER110?

Verify width, height, and depth against OEM cutout blueprint, leaving extra rear space for cords, hoses, or condenser airflow.

Where is the serial tag located on Broan AER110?

Inspect the inner liner wall, door rim, or tub flange via the Broan serial guide to decode build month and year before buying replacement assemblies.

Related guides

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
  2. Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
  3. Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)