Skip to main content
Ventilating Fans · Rank #129 of 900

Broan LP50100 Ventilating Fan Specs

Specified at 100.0 CFM and Fan Efficacy 10.5 CFM/W, Broan LP50100 scores higher efficiency than 85.4% of 900 ventilating fans in the U.S. ENERGY STAR directory. Shared internal engineering unites single SKU LP50100DC within a standard residential footprint. Evaluated over a 15-year NAHB benchmark service window, operating power equals rated service expectations across a 15-year NAHB lifespan with ENERGY STAR certified margin under DOE 10 CFR 430.

Rated Energy
Ventilating Fans
EIA Annual Cost
Not listed
Category Rank
#129 of 900
Capacity
100.0 CFM
NAHB Lifespan
15 years
Annual Energy Draw Certified Rank #129 / 900 (top 14.6%)
vs Ventilating Fans Median +5.9 CFM/W (+128.3%) EPA certified comparison
Federal Metric (Fan Efficacy) 10.5 CFM/W 10 CFR 430 certified
Est. Operating Cost Unrated Annual kWh not listed

What are the official specs and computed benchmarks for Broan LP50100?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.

Broan LP50100 — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)
Specification / Metric LP50100 Value Category / Federal Benchmark Computed Insight & Formula
Capacity 100.0 CFM [U.S. Environmental Protection Agency (ENERGY STAR)] Standard CFM rating Density unavailable
Listing & Release Released 2019 1 SKU Single model listing (1 SKU)
NAHB Service Life 15 years [National Association of Home Builders (NAHB)] 50% age gate: 7.5 yrs Evaluate repair vs net replacement once age passes 9.8 yrs
Fan Efficacy 10.5 CFM/W Bathroom/Utility Room 4 inch diameter

Which ventilating fans match LP50100 in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Ventilating Fans (Matched by Width & kWh Draw)
Peer Model Subtype kWh/yr Delta vs LP50100 Capacity Cutout Dimensions SKUs
Greenheck SP-LP0810 Bathroom/Utility Room Not listed Not listed 100.0 CFM Not listed 1
Venco SP-LP0810 Bathroom/Utility Room Not listed Not listed 100.0 CFM Not listed 1
Venco VQ-LP0810 Bathroom/Utility Room Not listed Not listed 100.0 CFM Not listed 1
ACIQ ANPD100-3 Bathroom/Utility Room Not listed Not listed 100.0 CFM Not listed 1
AUPU BF4-S10 Bathroom/Utility Room Not listed Not listed 100.0 CFM Not listed 1

Does LP50100 carry R-600a, duct, or installation boundaries?

LP50100 (Bathroom/Utility Room, 10.5 CFM/W) vents humid indoor air outdoors via 4 inch diameter (never terminate into an enclosed attic).

Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.

  • LP50100DC

Should you repair LP50100 or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

How much does running Broan LP50100 cost each year?

At 18.16 cents/kWh (EIA August 2026), Broan LP50100 draws certified ENERGY STAR status, equating to scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) across all 1 finish trim, specifically LP50100DC.

How efficient is Broan LP50100 compared with federal ceilings?

Measured against 10 CFR 430 certified, Broan LP50100 holds rank #129 out of 900 U.S. ENERGY STAR ventilating fans: +5.9 CFM/W (+128.3%) vs median 0.0 kWh/yr.

Which minor parts are exceptions to replacing Broan LP50100?

Routine wear items such as gaskets, lint filters, coin traps, or inlet mesh remain worthwhile past 7.5 years, whereas motor or board quotes above 50% net replacement favor replacement.

When is Broan LP50100 a poor match for a remodel?

Avoid Broan LP50100 if 100.0 CFM falls short of household demand, if hookups conflict with OEM cutout blueprint, or if local electricity tariffs justify the lowest-kWh quartile.

Do all variants in the Broan LP50100 line use identical energy?

Yes; every listed finish — including LP50100DC — shares the identical certified ENERGY STAR status ENERGY STAR test rating and 100.0 CFM volume.

What safety codes restrict Broan LP50100 disassembly?

Always shut off the electrical breaker and water shutoff valve before opening LP50100 service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

How should owners confirm cutout clearance for Broan LP50100?

Verify width, height, and depth against OEM cutout blueprint, leaving extra rear space for cords, hoses, or condenser airflow.

Where is the serial tag located on Broan LP50100?

Inspect the inner liner wall, door rim, or tub flange via the Broan serial guide to decode build month and year before buying replacement assemblies.

Related guides

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
  2. Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
  3. Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)