Commercial Electric 7132-12- Ventilating Fan Specs
Verified EPA ENERGY STAR test logs for Commercial Electric 7132-12- list Fan Efficacy 3.3 CFM/W and 80.0 CFM, giving this higher-draw Bathroom/Utility Room unit clear cost separation at -1.3 CFM/W (-28.3%) relative to the 4.6 CFM/W median. Built into a standard residential footprint, the assembly covers single SKU 7132-12-CE. Cumulative power cost runs rated service expectations across a 15-year NAHB lifespan while holding ENERGY STAR certified vs 10 CFR 430.
- Rated Energy
- Ventilating Fans
- EIA Annual Cost
- Not listed
- Category Rank
- #840 of 900
- Capacity
- 80.0 CFM
- NAHB Lifespan
- 15 years
What are the official specs and computed benchmarks for Commercial Electric 7132-12-?
Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.
| Specification / Metric | 7132-12- Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| Capacity | 80.0 CFM [U.S. Environmental Protection Agency (ENERGY STAR)] | Standard CFM rating | Density unavailable |
| Listing & Release | Released 2024 | 1 SKU | Single model listing (1 SKU) |
| NAHB Service Life | 15 years [National Association of Home Builders (NAHB)] | 50% age gate: 7.5 yrs | Evaluate repair vs net replacement once age passes 9.8 yrs |
| Fan Efficacy | 3.3 CFM/W | Bathroom/Utility Room | 4.00 inch depth X 0.00 inch width |
Which ventilating fans match 7132-12- in cutout width and energy draw?
Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.
| Peer Model | Subtype | kWh/yr | Delta vs 7132-12- | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| Broan AE80B | Bathroom/Utility Room | Not listed | Not listed | 80.0 CFM | Not listed | 1 |
| Broan AE80B = A000HFKT WITH AE80BF1 | Bathroom/Utility Room | Not listed | Not listed | 80.0 CFM | Not listed | 1 |
| Broan AE80B = A000HFKTC WITH AE80BF1 | Bathroom/Utility Room | Not listed | Not listed | 80.0 CFM | Not listed | 1 |
| Broan AE80B = A000HFNF WITH AE80BF1 | Bathroom/Utility Room | Not listed | Not listed | 80.0 CFM | Not listed | 1 |
| Broan AE80BR | Bathroom/Utility Room | Not listed | Not listed | 80.0 CFM | Not listed | 1 |
Does 7132-12- carry R-600a, duct, or installation boundaries?
7132-12- (Bathroom/Utility Room, 3.3 CFM/W) vents humid indoor air outdoors via 4.00 inch depth X 0.00 inch width (never terminate into an enclosed attic).
Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.
- 7132-12-CE
Should you repair 7132-12- or replace it under the 50% rule?
Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.
FAQ
Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.
How much electricity does the Commercial Electric 7132-12- draw each year?
EPA ENERGY STAR lists Commercial Electric 7132-12- at certified ENERGY STAR status, producing an estimated utility outlay of scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) at the U.S. EIA residential benchmark of 18.16 cents/kWh across 1 finish SKUs.
How does Commercial Electric 7132-12- compare against the federal limit?
Against the 10 CFR 430 certified, this Commercial Electric ventilating fan ranks #840 among 900 certified ventilating fans — -1.3 CFM/W (-28.3%) vs the 0.0 kWh/yr median.
When is repairing Commercial Electric 7132-12- out of warranty NOT worthwhile?
Avoid major mechanical or control-board repairs once Commercial Electric 7132-12- passes 7.5 years (half its 15-year NAHB lifespan) or whenever a technician quote reaches 50% of net replacement cost.
Who should NOT install the Commercial Electric 7132-12- ventilating fan?
Do not specify Commercial Electric 7132-12- (80.0 CFM) for commercial duty cycles, tight alcoves that cannot clear OEM cutout blueprint plus ventilation gaps, or inside an active year-1 manufacturer warranty period.
Which SKU trims map to the Commercial Electric 7132-12- appliance models?
CodeBench merges 1 finish code, led by 7132-12-CE, under 7132-12- because color suffixes share identical core power draw, 80.0 CFM volume, and outer cabinet dimensions.
What safety rules govern Commercial Electric 7132-12- repairs?
Always shut off the electrical breaker and water shutoff valve before opening 7132-12- service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.
How do 5 peer alternatives match up to Commercial Electric 7132-12-?
The peer table compares 5 ventilating fans selected closest to 7132-12- by cutout width, 80.0 CFM capacity, and certified ENERGY STAR status rating so homeowners can evaluate direct drop-in replacements.
How do you verify the build age of Commercial Electric 7132-12-?
Check the interior serial sticker with the Commercial Electric serial date guide rather than relying only on the 2024 catalog release year, especially when 10-year codes repeat.
Related guides
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
- Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)