Skip to main content
Ventilating Fans · Rank #529 of 900

Commercial Electric BF1115 Ventilating Fan Specs

Commercial Electric BF1115 (Bathroom/Utility Room) places #529 of 900 certified U.S. ventilating fans with Fan Efficacy 4.4 CFM/W and 160.0 CFM. Sized for a standard residential footprint, this chassis consolidates single SKU BF1115 to prevent duplicate parts lookup. Projected electricity totals rated service expectations across a 15-year NAHB lifespan at August 2026 EIA rates, keeping ENERGY STAR certified headroom under federal 10 CFR 430 rules.

Rated Energy
Ventilating Fans
EIA Annual Cost
Not listed
Category Rank
#529 of 900
Capacity
160.0 CFM
NAHB Lifespan
15 years
Annual Energy Draw Certified Rank #529 / 900 (tied with 32 at 4.4 CFM/W)
vs Ventilating Fans Median -0.2 CFM/W (-4.3%) EPA certified comparison
Federal Metric (Fan Efficacy) 4.4 CFM/W 10 CFR 430 certified
Est. Operating Cost Unrated Annual kWh not listed

What are the official specs and computed benchmarks for Commercial Electric BF1115?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.

Commercial Electric BF1115 — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)
Specification / Metric BF1115 Value Category / Federal Benchmark Computed Insight & Formula
Capacity 160.0 CFM [U.S. Environmental Protection Agency (ENERGY STAR)] Standard CFM rating Density unavailable
Listing & Release Released 2024 1 SKU Single model listing (1 SKU)
NAHB Service Life 15 years [National Association of Home Builders (NAHB)] 50% age gate: 7.5 yrs Evaluate repair vs net replacement once age passes 9.8 yrs
Fan Efficacy 4.4 CFM/W Bathroom/Utility Room 6.00 inch depth X 0.00 inch width

Which ventilating fans match BF1115 in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Ventilating Fans (Matched by Width & kWh Draw)
Peer Model Subtype kWh/yr Delta vs BF1115 Capacity Cutout Dimensions SKUs
S&P TD-125 In-line (single-port) Not listed Not listed 160.0 CFM Not listed 1
Tech Drive TD-BF-19 Bathroom/Utility Room Not listed Not listed 160.0 CFM Not listed 1
VENTECHLATION VF-BF-06 Bathroom/Utility Room Not listed Not listed 160.0 CFM Not listed 1
KOHLER 34454 Bathroom/Utility Room Not listed Not listed 150.0 CFM Not listed 2
KOHLER 34456 Bathroom/Utility Room Not listed Not listed 150.0 CFM Not listed 2

Does BF1115 carry R-600a, duct, or installation boundaries?

BF1115 (Bathroom/Utility Room, 4.4 CFM/W) vents humid indoor air outdoors via 6.00 inch depth X 0.00 inch width (never terminate into an enclosed attic).

Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.

  • BF1115

Should you repair BF1115 or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

How much does running Commercial Electric BF1115 cost each year?

At 18.16 cents/kWh (EIA August 2026), Commercial Electric BF1115 draws certified ENERGY STAR status, equating to scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) across all 1 finish trim, specifically BF1115.

How efficient is Commercial Electric BF1115 compared with federal ceilings?

Measured against 10 CFR 430 certified, Commercial Electric BF1115 holds rank #529 out of 900 U.S. ENERGY STAR ventilating fans: -0.2 CFM/W (-4.3%) vs median 0.0 kWh/yr.

Which minor parts are exceptions to replacing Commercial Electric BF1115?

Routine wear items such as gaskets, lint filters, coin traps, or inlet mesh remain worthwhile past 7.5 years, whereas motor or board quotes above 50% net replacement favor replacement.

When is Commercial Electric BF1115 a poor match for a remodel?

Avoid Commercial Electric BF1115 if 160.0 CFM falls short of household demand, if hookups conflict with OEM cutout blueprint, or if local electricity tariffs justify the lowest-kWh quartile.

Do all variants in the Commercial Electric BF1115 line use identical energy?

Yes; every listed finish — including BF1115 — shares the identical certified ENERGY STAR status ENERGY STAR test rating and 160.0 CFM volume.

What safety codes restrict Commercial Electric BF1115 disassembly?

Always shut off the electrical breaker and water shutoff valve before opening BF1115 service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

How should owners confirm cutout clearance for Commercial Electric BF1115?

Verify width, height, and depth against OEM cutout blueprint, leaving extra rear space for cords, hoses, or condenser airflow.

Where is the serial tag located on Commercial Electric BF1115?

Inspect the inner liner wall, door rim, or tub flange via the Commercial Electric serial guide to decode build month and year before buying replacement assemblies.

Related guides

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
  2. Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
  3. Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)