Skip to main content
Ventilating Fans · Rank #314 of 900

Delta SLM50-110LED- Ventilating Fan Specs

Spanning single SKU SLM50-110LED-C, Delta SLM50-110LED- logs Fan Efficacy 7.1 CFM/W inside a standard residential footprint built for 110.0 CFM. Out of 900 certified U.S. ventilating fans, this Bathroom/Utility Room model achieves upper-half efficiency: scores higher efficiency than 64.7% of 900 ventilating fans. Out-of-warranty owners weighing component quotes face rated service expectations across a 15-year NAHB lifespan and ENERGY STAR certified compliance under 10 CFR 430.

Rated Energy
Ventilating Fans
EIA Annual Cost
Not listed
Category Rank
#314 of 900
Capacity
110.0 CFM
NAHB Lifespan
15 years
Annual Energy Draw Certified Rank #314 / 900 (top 35.3%)
vs Ventilating Fans Median +2.5 CFM/W (+54.3%) EPA certified comparison
Federal Metric (Fan Efficacy) 7.1 CFM/W 10 CFR 430 certified
Est. Operating Cost Unrated Annual kWh not listed

What are the official specs and computed benchmarks for Delta SLM50-110LED-?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.

Delta SLM50-110LED- — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)
Specification / Metric SLM50-110LED- Value Category / Federal Benchmark Computed Insight & Formula
Capacity 110.0 CFM [U.S. Environmental Protection Agency (ENERGY STAR)] Standard CFM rating Density unavailable
Listing & Release Released 2022 1 SKU Single model listing (1 SKU)
NAHB Service Life 15 years [National Association of Home Builders (NAHB)] 50% age gate: 7.5 yrs Evaluate repair vs net replacement once age passes 9.8 yrs
Fan Efficacy 7.1 CFM/W Bathroom/Utility Room 4.00 inch depth X 0.00 inch width

Which ventilating fans match SLM50-110LED- in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Ventilating Fans (Matched by Width & kWh Draw)
Peer Model Subtype kWh/yr Delta vs SLM50-110LED- Capacity Cutout Dimensions SKUs
AERO PURE ABF110DHL5 Bathroom/Utility Room Not listed Not listed 110.0 CFM Not listed 1
AERO PURE ABF110DHL6 Bathroom/Utility Room Not listed Not listed 110.0 CFM Not listed 1
AUPU AV0511DSL3 Bathroom/Utility Room Not listed Not listed 110.0 CFM Not listed 1
Panasonic FV-0511VF1 Bathroom/Utility Room Not listed Not listed 110.0 CFM Not listed 2
Panasonic FV-0511VFL1 Bathroom/Utility Room Not listed Not listed 110.0 CFM Not listed 4

Does SLM50-110LED- carry R-600a, duct, or installation boundaries?

SLM50-110LED- (Bathroom/Utility Room, 7.1 CFM/W) vents humid indoor air outdoors via 4.00 inch depth X 0.00 inch width (never terminate into an enclosed attic).

Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.

  • SLM50-110LED-C

Should you repair SLM50-110LED- or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

How much does running Delta SLM50-110LED- cost each year?

At 18.16 cents/kWh (EIA August 2026), Delta SLM50-110LED- draws certified ENERGY STAR status, equating to scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) across all 1 finish trim, specifically SLM50-110LED-C.

How efficient is Delta SLM50-110LED- compared with federal ceilings?

Measured against 10 CFR 430 certified, Delta SLM50-110LED- holds rank #314 out of 900 U.S. ENERGY STAR ventilating fans: +2.5 CFM/W (+54.3%) vs median 0.0 kWh/yr.

Which minor parts are exceptions to replacing Delta SLM50-110LED-?

Routine wear items such as gaskets, lint filters, coin traps, or inlet mesh remain worthwhile past 7.5 years, whereas motor or board quotes above 50% net replacement favor replacement.

When is Delta SLM50-110LED- a poor match for a remodel?

Avoid Delta SLM50-110LED- if 110.0 CFM falls short of household demand, if hookups conflict with OEM cutout blueprint, or if local electricity tariffs justify the lowest-kWh quartile.

Do all variants in the Delta SLM50-110LED- line use identical energy?

Yes; every listed finish — including SLM50-110LED-C — shares the identical certified ENERGY STAR status ENERGY STAR test rating and 110.0 CFM volume.

What safety codes restrict Delta SLM50-110LED- disassembly?

Always shut off the electrical breaker and water shutoff valve before opening SLM50-110LED- service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

How should owners confirm cutout clearance for Delta SLM50-110LED-?

Verify width, height, and depth against OEM cutout blueprint, leaving extra rear space for cords, hoses, or condenser airflow.

Where is the serial tag located on Delta SLM50-110LED-?

Inspect the inner liner wall, door rim, or tub flange via the Delta serial guide to decode build month and year before buying replacement assemblies.

Related guides

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
  2. Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
  3. Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)