Fantech FG 4 (40402) Ventilating Fan Specs
Spanning single SKU FG 4 (40402), Fantech FG 4 (40402) logs Fan Efficacy 5.5 CFM/W inside a standard residential footprint built for 100.0 CFM. Out of 900 certified U.S. ventilating fans, this In-line (single-port) model achieves upper-half efficiency: #356 / 900 — tied with 16 peers, scores higher efficiency than 58.7% of 900 ventilating fans. Out-of-warranty owners weighing component quotes face rated service expectations across a 15-year NAHB lifespan and ENERGY STAR certified compliance under 10 CFR 430.
- Rated Energy
- Ventilating Fans
- EIA Annual Cost
- Not listed
- Category Rank
- #356 of 900
- Capacity
- 100.0 CFM
- NAHB Lifespan
- 15 years
What are the official specs and computed benchmarks for Fantech FG 4 (40402)?
Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.
| Specification / Metric | FG 4 (40402) Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| Capacity | 100.0 CFM [U.S. Environmental Protection Agency (ENERGY STAR)] | Standard CFM rating | Density unavailable |
| Listing & Release | Released 2022 | 1 SKU | Single model listing (1 SKU) |
| NAHB Service Life | 15 years [National Association of Home Builders (NAHB)] | 50% age gate: 7.5 yrs | Evaluate repair vs net replacement once age passes 9.8 yrs |
| Fan Efficacy | 5.5 CFM/W | In-line (single-port) | 4.00 inch diameter |
Which ventilating fans match FG 4 (40402) in cutout width and energy draw?
Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.
| Peer Model | Subtype | kWh/yr | Delta vs FG 4 (40402) | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| Spruce RB110 | In-line (single-port) | Not listed | Not listed | 100.0 CFM | Not listed | 1 |
| Air King ESQZ2303 | Range Hood | Not listed | Not listed | 100.0 CFM | Not listed | 1 |
| Air King ESQZ2306 | Range Hood | Not listed | Not listed | 100.0 CFM | Not listed | 1 |
| ACIQ ANP100 | Bathroom/Utility Room | Not listed | Not listed | 100.0 CFM | Not listed | 1 |
| Canarm CNP100 | Bathroom/Utility Room | Not listed | Not listed | 100.0 CFM | Not listed | 1 |
Does FG 4 (40402) carry R-600a, duct, or installation boundaries?
FG 4 (40402) (In-line (single-port), 5.5 CFM/W) vents humid indoor air outdoors via 4.00 inch diameter (never terminate into an enclosed attic).
Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.
- FG 4 (40402)
Should you repair FG 4 (40402) or replace it under the 50% rule?
Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.
FAQ
Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.
What annual electricity outlay should Fantech FG 4 (40402) owners budget?
Rated at certified ENERGY STAR status, Fantech FG 4 (40402) averages scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) under EIA's 18.16 cents/kWh U.S. average over 15 years of NAHB service life.
Where does Fantech FG 4 (40402) sit among 900 certified peers?
Out of 900 U.S. certified ventilating fans, Fantech FG 4 (40402) ranks #356 — Rank #356 / 900 (tied with 16 at 5.5 CFM/W) — against 10 CFR 430 certified.
Should owners repair a failing Fantech FG 4 (40402) past 15 years?
NAHB places median ventilating fan service life at 15 years; past 7.5 years, estimates exceeding 50% of net new price (after $150 5-yr savings) favor replacement.
Who is Fantech FG 4 (40402) NOT designed for?
Commercial establishments, alcoves smaller than OEM cutout blueprint, and households requiring different capacity than 100.0 CFM should review peer alternatives above.
Which model numbers belong to the Fantech FG 4 (40402) platform?
All 1 finish code maps to the identical FG 4 (40402) platform, notably FG 4 (40402): certified ENERGY STAR status vs 0.0 kWh/yr category median.
What safety checks precede opening Fantech FG 4 (40402) housings?
Always shut off the electrical breaker and water shutoff valve before opening FG 4 (40402) service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.
How does Fantech FG 4 (40402) fit standard residential cutouts?
Measuring OEM cutout blueprint at 100.0 CFM, FG 4 (40402) aligns closely with the 5 nearest peer ventilating fans ranked in the alternative table above.
Can you date Fantech FG 4 (40402) if purchase paperwork is missing?
Yes; check the cabinet serial tag in our Fantech serial decoder to confirm manufacture year and out-of-warranty status.
Related guides
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
- Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)